ملخص المحتوى في الصفحة رقم 1
Jiva TP/LT- 5600/5700/5800/8000
Touch Terminal w/ Slim Base
User’s Manual
Rev. B1
FCC Notes:
This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions manual, may
cause interference to radio communications. It has been tested and found to comply
with limits for a Class A digital device pursuant to subpart J of Part 15 of FCC Rules,
which are designed to provide reasonable protection against interf
ملخص المحتوى في الصفحة رقم 2
ALERT TO OUR HONORABLE CUSTOMERS: l Please always read thoroughly all the instructions and documents delivered with the product before you do anything about it. Don’t take any premature action before you have a full understanding of the consequences. l This product contains inside a Lithium battery and maybe also a sealed type Lead acid battery if the UPS battery option is ordered. Please always follow local environmental protection laws / regulations for disposal of used batteries and
ملخص المحتوى في الصفحة رقم 3
Standard Features: CPU: Eden 667 MHz or up for TP/LT-5600;C3 800 MHz for TP/LT- 5700; C3 1.0 GHz for TP/LT-5800; Celeron 2.0 GHz for TP/LT-8000 Jiva TP/LT-5800/8000 has both system fan and CPU fan with a fan control software in preloaded OS. nd An advanced slim base design supporting 2 LCD display or pole mount customer display in desktop mount application and easy wall mount conversion, storage room for HDD for TP/LT-5800/8000 series and optional UPS battery for all series in both desk
ملخص المحتوى في الصفحة رقم 4
Touch control functions: left/right button, double click, drag & draw (for Jiva TP only) Dual display support (per OS capability) VGA memory size shared from system memory (16 – 64 MB for TP/LT-5600/5700/5800, 16 – 128 MB for TP/LT-8000) Support high performance DDR DRAM with maximum memory size 1GB for TP/LT-5600/5700/5800, 2GB for TP/LT-8000 in two modules Integrated structure for optional security devices (KP-100, SD-100, SD- 200 or BC-100U) and optional top mount customer display P
ملخص المحتوى في الصفحة رقم 5
INSTALLATION GUIDES CAUTION: Before any installation or cable connection to the set, please always make certain that the system is turned off and the external power source to the set is removed to prevent electric hazard! Never touch any metal pin in the connectors or circuits to avoid high voltage hazard or electrostatic discharge damage unless the operator is well grounded. Failure to do the above will void the product warranty! OPENING CABLE COVER Please follow steps A to G sequent
ملخص المحتوى في الصفحة رقم 6
disconnection operation are not covered by product warranty! SEPARATING MAIN UNIT In order to settle the touch terminal properly in a point of sale system, all the cable connections have to be routed through its base, the stand assembly. Therefore, please observe the procedures from A to C below to separate the main unit from the stand assembly after all cables in cable cover disconnected. Step B: Press the Lock/Release button and meantime ... Step C: Slide the base stand assembly
ملخص المحتوى في الصفحة رقم 7
CABLE ROUTING Please route all cables through the cable passage to main unit in desktop mount application. Hold them together with the cable tie. Pass all cables (but those for HDD and UPS battery) through the cable exit to external connections. Then fix back the bottom plate if there is no option unit to install. INSTALLING UPS BATTERY The optional UPS battery is delivered in the carton if it is ordered. Please remove the UPS battery bracket fixing screw and slide left the UPS battery
ملخص المحتوى في الصفحة رقم 8
in squares in lower left picture and allow the main unit to slide down the winding grooves in the wall mount backpack - originally the base box. The stand assembly is not engaged in wall mount operation. Connect all cables coming out of the backpack into the cable cover area of main unit. The area required for wall mount application is determined by the main unit dimensions and is 375 mm in width and 315 mm in height. BASE MOUNT UPGRADE KIT On rear edge of the stand assembly, there is a
ملخص المحتوى في الصفحة رقم 9
will look like the right picture. Route the VGA through the cable exit of the base stand to the main unit. Connect the attached power adaptor for its power source. ROUTING THE CABLES Place all the cables required for connections to the main unit except those for the integrated attachment through the front part inside the stand assembly. Be sure not to damage any cable during this operation. Route Cables through Front Part Connect this End to Main Unit Now, turn the adjustabl
ملخص المحتوى في الصفحة رقم 10
After the battery is nearly exhausted, the user must change a new battery otherwise the system RTC and system configuration setup will be lost. SIDE & REAR TOP MOUNT UPGRADE KIT Please follow the instructions in the manuals delivered with the side mount upgrade kit: KP100, SD100, SD200 or BC100 and the rear top mount upgrade kit PD302 to fit them in Jiva system construction. The USB power arrangement in this system has been particularly designed to help smooth start up of the fingerprin
ملخص المحتوى في الصفحة رقم 11
http://www.posiflex.com.tw DESKTOP MOUNTING Matching Holes Matching Pegs Round Part Slot Part Removal Hollow Match the matching pegs on the back of the main unit against the matching holes on the stand assembly. First aim the matching pegs toward the upper round part of the hole and make sure that all pegs are inside the holes. Then slide the main unit down to move the pegs into the lower slot part of the holes till it clicks. Note that all the cables come out of t
ملخص المحتوى في الصفحة رقم 12
plastic latchkey that is used when removing the cable cover, but be sure to turn it in the clockwise direction to lock the cover in place. Re-adjust the tilt angle of the screen for best viewing. Connect the cables to appropriate external devices through the cable exit at the bottom of stand assembly. Please make sure that each connector has to be connected to the right device in the right way. CAUTION: On doing any insertion or extraction of any connector, please always hold the connec
ملخص المحتوى في الصفحة رقم 13
subfolder “\drivers” in OS recovered HDD and the latest versions of these required drivers will be available on our web: http://www.posiflex.com.tw. Now please follow instructions from your system integrator for software recovery. OPERATING SYSTEM INSTALLATION This product is a highly professionalized equipment. The installation of an OS into a machine without any preloaded OS could constitute major difficulty for average user who either has barely limited technical knowledge of this p
ملخص المحتوى في الصفحة رقم 14
USING THE TOUCH POS APPLICATION ENVIRONMENT It is very important that you check the following operational guidelines: Ventilation This terminal must NOT be operated in an environment with restricted ventilation. The installation should be such that there is at least 25mm air clearance around any top or side ventilation holes. The installation must also be such that there is a free flow of air around the unit at ALL times. Operating Environment The equipment must not be operated or st
ملخص المحتوى في الصفحة رقم 15
connected there but found inoperable by such messages. Emergency treatment: The battery is constructed maintenance free and leakproof. It is well protected in Jiva system as long as the ambient temperature remains below 30°C and the ventilation of the Jiva system remains free. However, should any accident happen and the sulfuric acid from the battery spills on skin or clothing, wash immediately with water. If the acid comes in contact with eyes, rinse eyes with large amount of clean wat
ملخص المحتوى في الصفحة رقم 16
LED Status System Status External Power UPS Battery Powering Up Off Off Off Not present Not possible Off Off Off Present Not allowed Green Off On No influence Allowed Blue On On No influence Not required Blue/flash On Off Activated Not required Green/rapid Running at On Off Not required flash low capacity Hardware Power Switch The power switch located at left side of the main unit is a slide type switch. This switch controls the power on/off of the system. This switch turns the sys
ملخص المحتوى في الصفحة رقم 17
Automatic Power On Control The system may also turn on according to some preset conditions such as Modem Ring Up and Alarm Clock Wake Up or LAN Wake Up. To utilize Modem Ring Up or Alarm Clock Wake Up function, the user should enter the CMOS setup by pressing “Del” key at system boot up, choose for “PM Wake Up Events” in “Power Management Setup” and make the “Ring Power Up Control” enabled for Modem Ring Up or select the “Power Up by Alarm” for Alarm Clock Wake Up. Save the configuratio
ملخص المحتوى في الصفحة رقم 18
SERIAL PORTS – COM1/2/3/4 In Jiva system, there are 4 serial ports available. All the serial ports can supply a +5 V DC through pin 9 after proper jumper setting change. All 4 ports are standard RS232 serial ports as status at delivery. When a serial Modem is to be used in Jiva system, it is most recommended to use COM2 or COM3 or COM4 port for this purpose. In this way any hardware resource conflict is eliminated and the MODEM ring up function can be supported. For models of TP-5600/57
ملخص المحتوى في الصفحة رقم 19
TOUCH PANEL (for TP models only) All paragraphs below are applicable in TP-5615, TP-5715, TP-5815 or TP-8015 only. The user of LT-5615, LT-5715, LT-5815 or LT-8015 can ignore them and consider this user’s manual ends here. Mouse Emulation The touch panel in Jiva TP system uses PS2, RS232 or USB interface. When its driver is properly installed, this touch panel works exactly like a standard mouse. However, if the system is running under safe mode, most drivers are disabled in this mode
ملخص المحتوى في الصفحة رقم 20
sticky button tool in the program group “Posiflex USB Touch Tools” is installed in the preloaded Windows system with a USB interface touch panel controller. This program can also be obtained by download from the POSIFLEX web site. T31454 Part 20