ملخص المحتوى في الصفحة رقم 1
Service Questions: Contact Friedrich at (800) 541-6645
Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com
™
Breeze
A revolution in room cooling
Installation Instructions
for BRO412W1A
4000 - 12000 Btu
Friedrich Part No. 96091000 (Rev. 01)
ملخص المحتوى في الصفحة رقم 2
What’s in the carton? Accessories ITEM DESCRIPTION QTY 1. Breeze indoor module with 25 ft. connecting 1. CONTROL BOX COVER DOOR 1 line attached 2. CONTROL BOX COVER 1 2. Wall mounting template and bracket for in- 3. WIRE TIE 2 door module 4. CONNECTING LINE BENDING GUIDE 1 5. ELECTRICAL CORD RETENTION BRACKET 1 3. Breeze outdoor module 6. WALL OPENING FILL GASKET 1 4. Outdoor module connection covers 7. OUTDOOR UNIT WASHER FOR ANCHOR SCREW 4 5. Mounting pad for outdoor module 8. OUTDOOR UNIT A
ملخص المحتوى في الصفحة رقم 3
CAUTION SHOCK HAZARD - DO NOT PLUG-IN indoor unit until all installation work is completed! Connect to a single dedicated circuit sized for the load. DO NOT kink or bend refrigeration line-set less than 3” radius – A connecting line bending guide is provided. Line-set is under high pressure – DO NOT Puncture line-set. DO NOT Heat line-set. Always follow all local and national codes when installing equipment. Obtain the help of trained, skilled worker where necessary. STEP 1 - Determine how you
ملخص المحتوى في الصفحة رقم 4
Now that you have determined where the modules will be placed, it is time to install the Breeze air conditioning system. STEP 2 – Hang wall mount bracket Using the paper template as a guide, locate two studs behind screw hole locations in the template. It is preferable to mount the hanging plate on studs. If two studs are not available, utilize anchors appropriate for the wall type with a combined weight capacity of at least 60 lbs. Standard wood screws and drywall anchors are provided.
ملخص المحتوى في الصفحة رقم 5
Option 2: Window Installation Using Friedrich SimpleSill™ 1. Be sure window sill is clean and free of dirt and debris. With the window raised, place bottom seal gasket (trimmed to window width) firmly against window sill (adhesive side down). Expand the SimpleSill™ 1” greater than the width of the win- dow and install the securing pin. Place one end of the SimpleSill™ into the window opening so it is against the corner of the window frame and sill. Raise the other side of the SimpleSill™ 6-
ملخص المحتوى في الصفحة رقم 6
STEP 6 - Place the mounting pad. STEP 6 Position the mounting pad so that the mounting holes are away from the house. Set the outdoor module on the mounting pad so that the module feet align with the mounting holes. Screw the outdoor module to the mounting pad with the 4 condenser pad installation washers and screws provided (Items #7 and #8 in the Accessories List). STEP 7 – Connect the quick connector from the indoor line set outdoor module. 1. Open lock handle on line- 2. Grasp outer loc
ملخص المحتوى في الصفحة رقم 7
STEP 9 – Locate the condensate drain. The connecting line has a built in condensate line hose that removes the moisture collected from the indoor module. The hose must be located in an appropriate location for drainage. Because the hose relies on gravity to drain, it is important that the hose only points downward for the entire length of the hose. If the connecting line is rolled to store the excess line as shown in Step 6, the drain line may be removed from the connecting line as shown be
ملخص المحتوى في الصفحة رقم 8
Service Questions: Contact Friedrich at (800) 541-6645 Sales Inquiries: Contact Sylvane at (800) 934-9194 or visit sylvane.com Remote Control Operation 1. START / STOP Turns the Breeze unit on or off. ▼ /▲ Arrow Press to raise or lower the temperature setting. Temperature setting range is between 61�F – 86�F. 2. FAN/AUTO Adjusts the fan speed or sets fan to ‘AUTO’ operation. Selectable speeds are LOW, MEDIUM, HIGH or AUTO. AUTO will automatically adjust the fan speed to maintain th