ملخص المحتوى في الصفحة رقم 1
PA13-SERIES PACKAGED AIR CONDITIONERS
Cooling Capacities: 23,000 to 56,000
SEER: 13.0
GREEN REFRIGERANT R-410A
FRONT (INDOOR AIRFLOW) END OF UNIT
BACK (OUTDOOR AIRFLOW) END OF UNIT
Standard Engineered Features Field Installed Accessories
Optional Field Installed Electric Heat
Compressor Control Module:
Air Conditioner Compressor:
Strips:
Built-in off-delay timer adjustable from
Reciprocating compressors with
With automatic limit and thermal cutoff.
crankcase heaters are standard on 2, 30 seconds
ملخص المحتوى في الصفحة رقم 2
Cooling Capacities and Efficiency Ratings MODELS Phase BTUH SEER P1 A13242-A 20 3,000 13.0 P1 A13302-A 20 9,000 13.0 P3 A13362-A, -B 10 and 30 4,00 13.0 P3 A13422-A, -B, -C 10 and 40 3,00 13.5 P3 A13482-A, -B, -C 10 and 40 6,50 13.0 P3 A13602-A, -B, -C 10 and 50 6,00 13.0 Tested and Certified in accordance with ARI Standard 210/240-2003. General Specifications Model PA13242-A PA13302-A PA13362-A PA13362-B PA13422-A PA13422-B PA13422-C PA13482-A PA13482-B PA13482-C PA13602-A PA13602-B PA13602-C E
ملخص المحتوى في الصفحة رقم 3
Optional Field Installed Electric Heater Packages Optional field-installed electric heater packages are available for 5 through 15Kw capacities. The heater packages are UL listed to be field-installed into the basic unit. They feature prewired control circuit wiring with plug-in connector. Simply slide the heater into the unit, plug in the pretested control circuit and connect the separate high voltage circuit wiring. IMPORTANT: While this electrical data is presented as a guide, it is importa
ملخص المحتوى في الصفحة رقم 4
Form No. S3383-1112 Supersedes S3383-510 Page 4 of 8 Cooling Application Data — Outdoor Temperature 1 Outdoor Temperature°F Cooling Model D.B./W.B. 2 2 2 2 2 Capacity 55°F 60°F 65°F 70°F 75°F 80°F 85°F 90°F 95°F 100°F 105°F 110°F 115°F 120°F Total Cooling 30,100 29,000 27,900 26,750 25,650 24,550 23,500 22,400 21,300 20,100 18,850 17,650 16,450 15,200 75/62 Sensible Cooling 20,600 20,100 19,700 19,250 18,800 18,400 17,950 17,500 17,100 16,650 16,200 15,750 15,250 14,800 Total Cooling 31,900 30,
ملخص المحتوى في الصفحة رقم 5
Form No. S3383-1112 Supersedes S3383-510 Page 5 of 8 Slab Mounting at Ground Level Side Air Outlet The distance between View outside wall and unit 1 inch clearance varies with installation between duct and Elevated Mounting Platforms (Field Constructed) requirements. Package Unit any combustible material if distance between outside wall and unit is less Supply Duct than 3 feet (needed on electric heat Mounting Slab units only). Return Duct 1/4 inch per foot slope away from building 12" min. if i
ملخص المحتوى في الصفحة رقم 6
Unit Dimensions W L A D E B Compressor access door Control panel door High voltage knockout Low voltage knockout Heater package knockout Supply opening C Heater package access panel Drain access Return opening F Condenser fan H Condenser air intake grille Blower motor access door 47 11/16" G Condenser air intake grille Unit Dimension Chart Supply Size Return Size Unit Overall Dimensions Unit General Dimensions Unit A C B C H (height) L (length) W (width) D E F G PA/PH1324,1330,1336 5.875 32.875
ملخص المحتوى في الصفحة رقم 7
Optional Equipment — Roof Hood • Shipped knocked down • Built-in filter • Polyester baked enamel galvanneal cabinet • Fresh air damper assembly provides up to 15% outside air. • Heavy insulation - 1/2 inch • Requires prefabricated roof curb 9042-003 or 9042-004. Order separately. Model No.At pplicable To Shipping Weigh RHP313-A20 , 2-1/2 and 3 ton models 11 RHP513-A30 -1/2, 4 and 5 ton models 12 † Equivalent units - Shipping Performance and Application Data — RHP RHP313-A Ventilation Air RHP51
ملخص المحتوى في الصفحة رقم 8
Optional Equipment — Energy Recovery Ventilator Model No. Shipping Weight • Assures continuous supply of fresh air and reduction of all indoor air pollutants. IAQ ASHRAE 62.1 • Provides 250 to 400 CFM (adjustable) of outside air and exhaust. Efficiencies up to 77% heating and 65% cooling. E. RVR-A3D-X (230/208V) 125 lbs • Designed for easy installation on roof hoods RHP313-A and RHP513-A. E. RVR-C3D-X (460) 125 lbs PERFORMANCE AND APPLICATION DATA - ERVR-A3C Summer Cooling Performance (Indoor