ملخص المحتوى في الصفحة رقم 1
H8/3001 FP-80A
User System Interface Cable
(HS3001ECH61H)
for E6000 Emulator
User’s Manual
HS3001ECH61HE(B)
ملخص المحتوى في الصفحة رقم 2
Cautions 1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s patent, copyright, trademark, or other intellectual property rights for information contained in this document. Renesas bears no responsibility for problems that may arise with third party’s rights, including intellectual property rights, in connection with use of the information contained in this document. 2. Products and product specifications may be subject to change without notice.
ملخص المحتوى في الصفحة رقم 3
Preface Thank you for purchasing this user system interface cable (HS3001ECH61H) for the Renesas’s original microprocessor H8/3001. The HS3001ECH61H is a user system interface cable that connects an H8/3052 series E6000 emulator (HS3052EPI61H; hereinafter referred to as the emulator) to the IC socket for a FP-80A package for the H8/3001 MCU on the user system. i
ملخص المحتوى في الصفحة رقم 4
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures......................................................................4 2.1 Connecting User System Interface Cable to Emulator Station .........................................4 2.2 Connecting User System Interface Cable to User System ................................................6 2.2.1 Installing IC Socket ..........................
ملخص المحتوى في الصفحة رقم 5
Section 1 Configuration CAUTION Use an IC149-080-017-B5 socket (manufactured by YAMAICHI ELECTRONICS Co., Ltd.) for the FP-80A package IC socket on the user system. Figure 1 shows the configuration of the HS3001ECH61H user system interface cable for the FP-80A package. 1
ملخص المحتوى في الصفحة رقم 6
Figure 1 HS3001ECH61H User System Interface Cable 2
ملخص المحتوى في الصفحة رقم 7
Table 1 lists the HS3001ECH61H components. Please make sure you have all of these components when unpacking. Table 1 HS3001ECH61H Components No. Component Quantity Remarks 1 Cable body 1 Flat cable 2 Cable head 1 3 IC socket 1 For the FP-80A package 4 Socket cover 1 For installing an FP-80A-packaged MCU 5 Screws (M2.0 x 12 mm) 4 For fastening cable head (with four flat washers) 6 Screws (M2.0 x 8 mm) 4 For installing an FP-80A-packaged MCU (with four flat washers) 7 Documentation 1
ملخص المحتوى في الصفحة رقم 8
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before c
ملخص المحتوى في الصفحة رقم 9
Figure 2 Connecting User System Interface Cable to Emulator Station 5
ملخص المحتوى في الصفحة رقم 10
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable head to the user system, follow t
ملخص المحتوى في الصفحة رقم 11
2.2.4 Fastening Cable Head CAUTION 1. Use a Philips-type screwdriver whose head matches the screw head. 2. The tightening torque must be 0.0784 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket contact error may be caused by a crack in the IC soc
ملخص المحتوى في الصفحة رقم 12
Fasten the user system interface cable head to the IC socket for an FP-80A package on the user system with the four screws (M2.0 x 12 mm; with flat washers) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Figure 3 Connecting User System Interf
ملخص المحتوى في الصفحة رقم 13
2.2.5 Fastening Cable Body Connect the cable body to the cable head. Cable body Removing Push the remove jig Remove jig Cable head User system Figure 4 Fastening Cable Body 9
ملخص المحتوى في الصفحة رقم 14
2.3 Recommended Dimensions for User System Mount Pad Figure 5 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for an FP-80A package (IC149-080-017-B5: manufactured by YAMAICHI ELECTRONICS Co., Ltd.). Note that the dimensions in figure 5 are somewhat different from those of the actual chip's mount pad. 20.50 (min.) 14.70 (max.) 0.65 19 = 12.35 0.1 + 0.1 0.35 0.65 0.05 - 0.05 Unit: mm Figure 5 Recommended Dimensions for Mount Pad 10
ملخص المحتوى في الصفحة رقم 15
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 6. Figure 6 Dimensions for User System Interface Cable Head 11
ملخص المحتوى في الصفحة رقم 16
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 7. Figure 7 Resulting Dimensions after Connecting User System Interface Cable 12
ملخص المحتوى في الصفحة رقم 17
Section 3 Installing the MCU to the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a Philips-type screwdriver whose head matches the screw head. 3. The tightening torque must be 0.0784 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may brea
ملخص المحتوى في الصفحة رقم 18
Screws (M2.0 x 8 mm) with flat washers Socket cover MCU Pin 1 mark IC socket (IC149-080-017-B5 manufactured by User system YAMAICHI ELECTRONICS Co., Ltd.) Figure 8 Installing MCU to User System 14
ملخص المحتوى في الصفحة رقم 19
Section 4 Verifying Operation 1. When using the H8/3052 series E6000 emulator (HS3052EPI61H), turn on the emulator according to the procedures described in the H8/300H Series E6000 Emulator User's Manual (HS300HEPI61HE). 2. Verify the user system interface cable connections by accessing the external memory and ports to check the bus states of the pins. If an error is detected, recheck the soldered IC socket and the location of pin 1. 3. The emulator connected to this user system interf
ملخص المحتوى في الصفحة رقم 20
Section 5 Notice 1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable head before inserting the cable head into the user system IC socket. 2. The dimensions of the recommended mount pad for the user system IC socket are different from those of the MCU. 3. This user system interface cable is specifically designed for the HS3052EPI61H emulator. Do not use this cable with any other emulator station. 4. To prevent breaking of wires in the ca