H8S/2168 Group TFP-144
User System Interface Cable
for E6000 Emulator
HS2168ECN61H User’s Manual
Renesas Microcomputer Development Environment System
H8S Family / H8S/2100 Series
Rev.2.00
2003.12.25
ملخص المحتوى في الصفحة رقم 2
Preface Thank you for purchasing this user system interface cable (HS2168ECN61H) for the Renesas’ original microcomputer H8S/2168 group. The HS2168ECN61H is a user system interface cable that connects an H8S/2168 group E6000 emulator (HS2168EPI61H; hereinafter referred to as the emulator) to the IC socket for a TFP-144 package on the user system. i
ملخص المحتوى في الصفحة رقم 3
Contents Section 1 Configuration....................................................................................1 Section 2 Connection Procedures......................................................................3 2.1 Connecting User System Interface Cable to Emulator Station .........................................3 2.1.1 Connecting User System Interface Cable to Cable Body Connector...................4 2.1.2 Connecting EIO Board 2 to Emulator..................................
ملخص المحتوى في الصفحة رقم 4
Section 1 Configuration CAUTION Use an NQPACK144SE socket (manufactured by Tokyo Eletech Corporation) for the TFP-144 package IC socket on the user system. Figure 1 shows the configuration of the HS2168ECN61H user system interface cable for the TFP-144 package. To emulator station Screws (M2.6 x 6 mm) CTS screws (M3 x 6 mm) for fastening the emulator station Cable body EIO board 2 EIO board 1 Screws (M2.0 x 10 mm) Screws (M2.0 x 6 mm) (for fastening cable head) Socket cover Cabl
ملخص المحتوى في الصفحة رقم 5
Table 1 lists the HS2168ECN61H components. Please make sure you have all of these components when unpacking. Table 1 HS2168ECN61H Components No. Component Quantity Remarks 1 Cable body 1 Includes coaxial cable and two EIO boards 2 Cable head 1 3 IC socket 1 For the TFP-144 package 4 Socket cover 1 For installing a TFP-144 packaged MCU 5 Screws (M2.6 x 6 mm) 2 For fastening EIO board 2 6 Screws (M2.0 x 10 mm) 4 For fastening cable head 7 Screws (M2.0 x 6 mm) 4 For installing a TFP-14
ملخص المحتوى في الصفحة رقم 6
Section 2 Connection Procedures 2.1 Connecting User System Interface Cable to Emulator Station WARNING Observe the precautions listed below. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. 1. Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before c
ملخص المحتوى في الصفحة رقم 7
2.1.1 Connecting User System Interface Cable to Cable Body Connector After making sure the direction of the cable body connector is correct, firmly insert the cable body connector into the emulator station socket, and fasten the emulator station with two CTS screws (M3 × 6 mm) (figure 2). Emulator station Cable body connector CTS screws (M3 x 6 mm) User system interface cable Figure 2 Connecting User System Interface Cable to Emulator Station (1) 4 E6000
ملخص المحتوى في الصفحة رقم 8
2.1.2 Connecting EIO Board 2 to Emulator 1. Remove four screws at the side of the emulator station. 2. Pull up and remove the cover of the emulator casing. 3. Insert connector P5 of EIO board 2 into connector P5 in the emulator station. 4. Fasten EIO board 2 with the provided two screws (M2.6 × 6 mm). 5. Set up the coaxial cable, which has been connected to EIO board 2, into a gutter of the emulator station. 6. Set the cover of the emulator station and fasten four screws. EIO board 2 c
ملخص المحتوى في الصفحة رقم 9
2.1.3 Removing EIO Board 2 from Emulator 1. Remove four screws from the side of the emulator station. 2. Pull up and remove the cover of the emulator casing. 3. Remove two screws (M2.6 × 6 mm) from EIO board 2. 4. Remove EIO board 2 from connector P5 of the emulator station. 5. Remove the coaxial cable, which has been connected to EIO board 2, from a gutter of the emulator station. 6. Set the cover of the emulator station and fasten four screws. 6
ملخص المحتوى في الصفحة رقم 10
2.2 Connecting User System Interface Cable to User System WARNING Always switch OFF the user system and the emulator product before the USER SYSTEM INTERFACE CABLE is connected to or removed from any part. Before connecting, make sure that pin 1 on both sides are correctly aligned. Failure to do so will result in a FIRE HAZARD and will damage the user system and the emulator product or will result in PERSONAL INJURY. The USER PROGRAM will be LOST. To connect the cable he
ملخص المحتوى في الصفحة رقم 11
Use the guide pins provided to determine where to install the IC socket, as shown in figure 4. Pin 1 Guide pins 4 projections to apply IC socket epoxy resin adhesive to (NQPACK144SE manufactured by Tokyo Eletech Corporation) Bottom view of IC socket User system Figure 4 Location Setting of IC Socket 2.2.2 Soldering IC Socket After fastening, solder the IC socket for a TFP-144 package to the user system. CAUTION Be sure to completely solder the leads so that the solder slops gen
ملخص المحتوى في الصفحة رقم 12
2.2.3 Inserting Cable Head CAUTION Check the location of pin 1 before inserting. Align pin 1 on the IC socket for a TFP-144 package on the user system with pin 1 on the user system interface cable head, and insert the user system interface cable head into the IC socket on the user system, as shown in figure 5. 2.2.4 Fastening Cable Head CAUTION 1. Use a screwdriver whose head matches the screw head. 2. The tightening torque must be 0.054 N•m or less. If the applied torque cann
ملخص المحتوى في الصفحة رقم 13
Fasten the user system interface cable head to the IC socket for a TFP-144 package on the user system with the four screws (M2.0 × 10 mm) provided. Each screw should be tightened a little at a time, alternating between screws on opposing corners. Take special care, such as manually securing the IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening the screws or twisting the components. Screws (M2.0 x 10 mm) Pin 1 Cable head IC socket (NQPACK144S
ملخص المحتوى في الصفحة رقم 14
2.2.5 Fastening Cable Body Connect the cable body and EIO board 1 to the cable head. Removing Cable body Push the lower part of EIO board 1 with your fingers EIO board 1 Cable body Remove jig EIO board 1 Cable head User system Figure 6 Fastening Cable Body and EIO Board 1 When removing the cable body or EIO board 1, push the unfastening jigs. If the lower part of the cable body is pushed, EIO board 1 may be removed. Push the lower part of EIO board 1 with your fingers. 11
ملخص المحتوى في الصفحة رقم 15
2.3 Recommended Dimensions for User System Mount Pad Figure 7 shows the recommended dimensions for the mount pad (footprint) for the user system with an IC socket for a TFP-144 package (NQPACK144SE: manufactured by Tokyo Eletech Corporation). Note that the dimensions in figure 7 are somewhat different from those of the actual chip's mount pad. 0.40 X 35 = 14.00 ± 0.05 0.40 ± 0.05 0.2 ± 0.05 3.0 - Ø1.0 8.0 Unit: mm Figure 7 Recommended Dimensions for Mount Pad 12 19.10 min 15.10 MAX
ملخص المحتوى في الصفحة رقم 16
2.4 Dimensions for User System Interface Cable Head The dimensions for the user system interface cable head are shown in figure 8. 25.0 20.5 66.0 Unit: mm Tolerance: ±0.5 mm Figure 8 Dimensions for User System Interface Cable Head 13 25.6 25.0 76.2
ملخص المحتوى في الصفحة رقم 17
2.5 Resulting Dimensions after Connecting User System Interface Cable The resulting dimensions, after connecting the user system interface cable head to the user system, are shown in figure 9. Cable head Unit: mm IC socket Tolerance: ±0.5 mm (NQPACK144SE User system manufactured by Tokyo Eletech Corporation) Figure 9 Resulting Dimensions after Connecting User System Interface Cable 14 13.3 48.3
ملخص المحتوى في الصفحة رقم 18
Section 3 Installing the MCU on the User System CAUTION 1. Check the location of pin 1 before inserting. 2. Use a screwdriver whose head matches the screw head. 3. The tightening torque must be 0.054 N•m or less. If the applied torque cannot be accurately measured, stop tightening when the force required to turn the screw becomes significantly greater than that needed when first tightening. If a screw is tightened too much, the screw head may break or an IC socket
ملخص المحتوى في الصفحة رقم 19
Screws (M2.0 x 6 mm) Socket cover MCU Pin 1 IC socket (NQPACK144SE manufactured by Tokyo Eletech Corporation) User system Figure 10 Installing MCU to User System 16
ملخص المحتوى في الصفحة رقم 20
Section 4 User System Interface Circuit The microcomputer (H8S/2168) is installed in this user system interface cable for emulating the LPC function. An interface circuit, as shown in figure 11, is provided for the user system interface signal of the H8S/2168. Figure 12 and table 2 show the settings of switches. EIO board 1 (HS2168EIO61H) PE0/LAD0 H8S/2168 PE1/LAD1 N6 PE2/LAD2 LAD0, LAD1, 330 Ω 47 kΩ PE3/LAD3 LAD2, LAD3, SW1 to 8 PE4/LFRAME_N LFRAME_N, PE5/LRESET_N LRESET_N, PE6/LCLK 330 Ω