ملخص المحتوى في الصفحة رقم 1 
                    
                        H8S/2643 Series
FP-144 
User System Interface Cable 
(HS2643ECH61H) 
for E6000 Emulator 
User’s Manual 
 
 
 
 
 
 
HS2643ECH61HE(C)                                                                                                                                                                                                                                                                                                                                                                                
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Cautions  1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s  patent, copyright, trademark, or other intellectual property rights for information contained in  this document.  Renesas bears no responsibility for problems that may arise with third party’s  rights, including intellectual property rights, in connection with use of the information contained  in this document.  2. Products and product specifications may be subject to change without notice.
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        Preface  Thank you for purchasing this user system interface cable (HS2643ECH61H) for the Renesas’s  original microcomputer H8S/2643 series.  The HS2643ECH61H is a user system interface cable that connects an H8S/2633 series E6000  emulator (HS2633EPI61H; hereinafter referred to as the emulator) to the IC socket for a FP-144  package for the H8S/2643 series MCU on the user system.     i                                                                                                               
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        Contents    Section 1    Configuration....................................................................................1  Section 2   Connection Procedures......................................................................3  2.1 Connecting User System Interface Cable to Emulator Station .........................................3  2.2 Connecting User System Interface Cable to User System ................................................5  2.2.1 Installing IC Socket ..........................
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Section 1    Configuration  CAUTION    Use an NQPACK144SD socket (manufactured by Tokyo    Eletech Corporation) for the FP-144 package IC socket    on the user system.   Figure 1 shows the configuration of the HS2643ECH61H user system interface cable for the   FP-144 package.    Figure 1   HS2643ECH61H User System Interface Cable  1                                                                                                                                                                      
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        Table 1 lists the HS2643ECH61H components.  Please make sure you have all of these components  when unpacking.  Table 1 HS2643ECH61H Components  No. Component Quantity Remarks  1 Cable body 1 Flat cable  2 Cable head 1    3 IC socket 1 For the FP-144 package  4 Socket cover 1 For installing a FP-144 packaged MCU  5 Screws (M2 x 10 mm) 4 For fastening cable head   6 Screws (M2 x 6 mm) 4 For installing a FP-144 packaged MCU   7 Guide pins (φ 1 mm) 3 For determining the IC socket location  8 Screwd
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        Section 2   Connection Procedures  2.1 Connecting User System Interface Cable to Emulator Station  WARNING     Observe the precautions listed below.  Failure to do so    will result in a FIRE HAZARD and will damage the user    system and the emulator product or will result in    PERSONAL INJURY.  The USER PROGRAM will be    LOST.     1.  Always switch OFF the user system and the emulator    product before the USER SYSTEM INTERFACE CABLE     is connected to or removed from any part.  Before     c
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        Emulator station Cable body connector User system interface cable   Figure 2   Connecting User System Interface Cable to Emulator Station  4    E6000                                                                                                                                                                                                                                                                                                                                                               
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        2.2 Connecting User System Interface Cable to User System  WARNING     Always switch OFF the user system and the emulator    product before the USER SYSTEM INTERFACE CABLE    is connected to or removed from any part.  Before    connecting, make sure that pin 1 on both sides are correctly    aligned.  Failure to do so will result in a FIRE HAZARD and    will damage the user system and the emulator product or    will result in PERSONAL INJURY.  The USER PROGRAM will    be LOST.    To connect the c
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        Guide pins 4 projections to apply epoxy resin adhesive to  IC socket Pin 1 (NQPACK144SD manufactured by Tokyo Eletech Corporation) Bottom view of IC soket User system   Figure 3   Location Setting of IC Socket  2.2.2 Soldering IC Socket  After fastening, solder the IC socket for a FP-144 package to the user system.   CAUTION    Be sure to completely solder the leads so that the solder    slops gently over the leads and forms solder fillets. (Use    slightly more solder than the MCU.)  2.2.3 Inse
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        2.2.4 Fastening Cable Head  CAUTION   1. Use the screwdriver provided for tightening screws.   2. The tightening torque must be 0.054 N•m or less.      If the applied torque cannot be accurately measured,     stop tightening when the force required to turn the screw     becomes significantly greater than that needed when first     tightening.  If a screw is tightened too much, the screw     head may break or an IC socket contact error may be     caused by a crack in the IC socket solder.   3. If
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        Fasten the user system interface cable head to the IC socket for a FP-144 package on the user system  with the four screws (M2 x 10 mm) provided.  Each screw should be tightened a little at a time,  alternating between screws on opposing corners.  Take special care, such as manually securing the  IC socket soldered area, to prevent the soldered IC socket from being damaged by overtightening  the screws or twisting the components.   Screws (M2 x 10mm) Cable head IC socket (NQPACK144SD manufacture
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        2.2.5 Fastening Cable Body  Connect the cable body to the cable head.  Cable body Removing Push the remove jig Remove jig Cable head User system   Figure 5   Fastening Cable Body  9                                                                                                                                                                                                                                                                                                                               
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        2.3 Recommended Dimensions for User System Mount Pad  Figure 6 shows the recommended dimensions for the mount pad (footprint) for the user system with  an IC socket for a FP-144 package (NQPACK144SD: manufactured by Tokyo Eletech  Corporation).  Note that the dimensions in figure 6 are somewhat different from those of the actual  chip's mount pad.    Figure 6   Recommended Dimensions for Mount Pad  10                                                                                                
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        2.4 Dimensions for User System Interface Cable Head  The dimensions for the user system interface cable head are shown in figure 7.      Figure 7   Dimensions for User System Interface Cable Head  11                                                                                                                                                                                                                                                                                                             
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        2.5 Resulting Dimensions after Connecting User System Interface Cable  The resulting dimensions, after connecting the user system interface cable head to the user system,  are shown in figure 8.      Figure 8   Resulting Dimensions after Connecting User System Interface Cable  12                                                                                                                                                                                                                            
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        Section 3   Installing the MCU to the User System  CAUTION   1. Check the location of pin 1 before inserting.   2. Use the screwdriver provided for tightening screws.   3. The tightening torque must be 0.054 N•m or less.      If the applied torque cannot be accurately measured,     stop tightening when the force required to turn the screw     becomes significantly greater than that needed when first     tightening.  If a screw is tightened too much, the screw     head may break or an IC socket c
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        Screws (M2 x 6 mm) Socket cover MCU Pin 1 IC socket (NQPACK144SD manufactured by User system Tokyo Eletech Corporation)   Figure 9   Installing MCU to User System  14                                                                                                                                                                                                                                                                                                                                              
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        Section 4   Verifying Operation  1. When using the E6000 emulator for the H8S/2633 series, turn on the emulator according to the  procedures described in the H8S Series E6000 Emulator User's Manual (HS2000EPI61HE).  2. Verify the user system interface cable connections by accessing the external memory and ports  to check the bus states of the pins with the MEMORY_FILL command (emulator command).  If  an error is detected, recheck the soldered IC socket and the location of pin 1.  3. The emulator
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        Section 5   Notice  1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable  head before inserting the cable head into the user system IC socket.  2. The dimensions of the recommended mount pad for the user system IC socket are different from  those of the MCU.    3. This user system interface cable is specifically designed for the HS2633EPI61H emulator.  Do  not use this cable with any other emulator station.  4. To prevent breaking of wires in the cabl