                        H8/3337Y Series, H8/3334 Series 
TQFP-80C  
User System Interface Cable 
(HS3337ECN61H) 
for E6000 Emulator 
User’s Manual 
  HS3337ECN61HE(C)                                                                                                                                                                                                                                                                                                                                                                      
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                        Cautions  1. Renesas neither warrants nor grants licenses of any rights of Renesas’s or any third party’s  patent, copyright, trademark, or other intellectual property rights for information contained in  this document.  Renesas bears no responsibility for problems that may arise with third party’s  rights, including intellectual property rights, in connection with use of the information  contained in this document.  2. Products and product specifications may be subject to change without notice.
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        Preface  Thank you for purchasing the E6000 emulator for the Renesas’s original microprocessor H8/300  series.  The HS3337ECN61H is a user system interface cable that connects an H8/300 series E6000  emulator (HS3008EPI60H; hereinafter referred to as the emulator) to the IC socket for a TQFP- 80C package (package code: TFP-80C) for the H8/3337Y series or H8/3334 series MCU on the  user system.    i                                                                                                   
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        Contents  Preface .........................................................................................................i  Section 1    Configuration....................................................................................1  Section 2   Connection Procedures......................................................................4  2.1 Connecting User System Interface Cable to Emulator Station .........................................4  2.2 Connecting User System Interface Cable to Us
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                        Section 1    Configuration  CAUTION    Use an IC149-080-058-B51 socket (manufactured by    YAMAICHI ELECTRONICS Co., Ltd.) for the TFP-80C package    IC socket on the user system.  Figure 1 shows the configuration of the HS3337ECN61H user system interface cable for the   TFP-80C package.  1                                                                                                                                                                                                                 
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                        To emulator station Cable body Screws (M2.6 x 12 mm) with flat washers  Screws (M2.6 x 8 mm) (for fastening cable head) with flat washers Socket cover Cable head IC socket User system   Figure 1   HS3337ECN61H User System Interface Cable  2                                                                                                                                                                                                                                                                    
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        Table 1 lists the HS3337ECN61H components.  Please make sure you have all of these  components when unpacking.  Table 1 HS3337ECN61H Components  No. Component Quantity Remarks  1 Cable body 1 Includes flat cable  2 Cable head 1    3 IC socket 1 For the TFP-80C package  4 Socket cover 1 For installing an TFP-80C-packaged MCU  5 Screws (M2.6 x 12 mm) 4 For fastening cable head (with four flat washers) 6 Screws (M2.6 x 8 mm) 4 For installing an TFP-80C-packaged MCU (with  four flat washers)  7 Docu
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        Section 2   Connection Procedures  2.1 Connecting User System Interface Cable to Emulator Station  WARNING     Always switch OFF the user system and the emulator    product before the USER SYSTEM INTERFACE CABLE    is connected to or removed from any part.  Before connecting,    make sure that pin 1 on both sides are correctly aligned.  Failure to    do so will damage the user system and the emulator product or will     result in PERSONAL INJURY.  The USER PROGRAM will be     LOST.  To connect t
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        2.2 Connecting User System Interface Cable to User System  WARNING     Always switch OFF the user system and the emulator    product before the USER SYSTEM INTERFACE CABLE    is connected to or removed from any part.  Before connecting,    make sure that pin 1 on both sides are correctly aligned.  Failure to    do so will damage the user system and the emulator product or will     result in PERSONAL INJURY.  The USER PROGRAM will be     LOST.  To connect the cable head to the user system, follow
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        2.2.4 Fastening Cable Head  CAUTION   1. Use a Phillips-type screwdriver whose head matches     the screw head.   2. The tightening torque must be 0.294 N•m or less.      If the applied torque cannot be accurately measured,     stop tightening when the force required to turn the screw     becomes significantly greater than that needed when first     tightening.  If a screw is tightened too much, the screw head     may break or an IC socket contact error may be caused by     a crack in the IC soc
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        Screws (M2.6 x 12 mm), flat washer Cable head Pin 1 IC socket (IC149-080-058-B51 manufactured by  YAMAICHI ELECTRONICS Co. Ltd.) User system   Figure 3   Connecting User System Interface Cable to User System  7                                                                                                                                                                                                                                                                                                  
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        2.2.5 Connecting Cable Body to Cable Head  Connect the cable body to the cable head.  Cable body Removing Push the remove jig Remove jig Cable head User system   Figure 4 Fastening Cable Body    8                                                                                                                                                                                                                                                                                                                
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        2.3 Recommended Dimensions for User System Mount Pad  Figure 5 shows the dimensions for the recommended mount pad (footprint) for the user system  with an IC socket for an TFP-80C package (IC149-080-058-B51: manufactured by YAMAICHI  ELECTRONICS Co., Ltd.).  Note that the dimensions in figure 5 are somewhat different from  those of the actual chip's mount pad.  15.10 (min.) 11.80 (max.) 0.50  19 = 9.50  0.05 0.50  0.05 0.30  0.05 Unit: mm   Figure 5  Recommended Dimensions for Mount Pad  9    0.
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        2.4 Dimensions for User System Interface Cable Head  The dimensions for the user system interface cable head are shown in figure 6.             Unit: mm Tolerance: –0.5 mm   Figure 6   Dimensions for User System Interface Cable Head  10                                                                                                                                                                                                                                                                        
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        2.5 Resulting Dimensions after Connecting User System Interface Cable  The resulting dimensions, after connecting the user system interface cable head to the user system,  are shown in figure 7.    Cable head IC socket  (IC149-080-058-B51 User system         Unit: mm manufactured by  Tolerance: –0.5 mm YAMAICHI ELECTRONICS Co. Ltd.)   Figure 7   Resulting Dimensions after Connecting User System Interface Cable  11                                                                                   
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                        Section 3   Installing the MCU to the User System  CAUTION   1. Check the location of pin 1 before inserting.   2. Use a Phillips-type screwdriver whose head matches     the screw head.   3. The tightening torque must be 0.294 N•m or less.      If the applied torque cannot be accurately measured,     stop tightening when the force required to turn the screw     becomes significantly greater than that needed when first     tightening.  If a screw is tightened too much, the screw head     may brea
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                        Screws (M2.6 x 8 mm) with flat washers Socket cover MCU Pin 1 IC socket  (IC149-080-058-B51 manufactured by  YAMAICHI ELECTRONICS Co., Ltd.) User system   Figure 8   Installing MCU to User System  13                                                                                                                                                                                                                                                                                                             
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        Section 4   Verifying Operation  1. When using the H8/300 series E6000 emulator (HS3008EPI60H), turn on the emulator  according to the procedures described in the H8/300 Series E6000 Emulator User's Manual  (HS3008EPI60HE).  2. Verify the user system interface cable connections by accessing the external memory and ports  to check the bus states of the pins.  If an error is detected, recheck the soldered IC socket and  the location of pin 1.  3. The emulator connected to this user system interfac
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        Section 5   Notice  1. Make sure that pin 1 on the user system IC socket is correctly aligned with pin 1 on the cable  head before inserting the cable head into the user system IC socket.  2. The dimensions of the recommended mount pad for the user system IC socket are different  from those of the MCU.    3. This user system interface cable is specifically designed for the HS3008EPI60H emulator.  Do  not use this cable with any other emulator station.    4. To prevent breaking of wires in the ca