ملخص المحتوى في الصفحة رقم 1
ACX048 ACXIO8-C ACX288-CTL ACX080-PS
ACX080 ACXIO8-SM ACXSFPC ACX160-PS
ACX160 ACXIO8-SPF ACXSFPS ACX288-PS
ACX288
™
ServSwitch DKM FX
Provides flexible and super-fast crosspoint
®
BL A C K B OX
switching of Full HD video in KVM enterprises.
Customer Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500)
Support FREE technical support 24 hours a day, 7 days a week: Call 724-746-5500 or fax
724-746-0746 • Mailing address: Black Box Corporation, 1000 Park
ملخص المحتوى في الصفحة رقم 2
Trademarks Used in this Manual Trademarks Used in this Manual Black Box and the Double Diamond logo are registered trademarks, and ServSwitch is a trademark, of BB Technologies, Inc. Mac is a registered trademark of Apple Computer, Inc. IBM is a registered trademark of International Business Machines Corporation. Java is a registered trademark of Oracle Corporation. TOSLINK is a registered trademark of Toshiba Corporation. Any other trademarks mentioned in this manual are acknowledged to be t
ملخص المحتوى في الصفحة رقم 3
FCC and IC RFI Statements/NOM Statement FEDERAL COMMUNICATIONS COMMISSION AND INDUSTRY CANADA RADIO FREQUENCY INTERFERENCE STATEMENTS This equipment generates, uses, and can radiate radio-frequency energy, and if not installed and used properly, that is, in strict accordance with the manufacturer’s instructions, may cause inter ference to radio communication. It has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Sub
ملخص المحتوى في الصفحة رقم 4
NOM Statement 4. Todas las instrucciones de operación y uso deben ser seguidas. 5. El aparato eléctrico no deberá ser usado cerca del agua—por ejemplo, cerca de la tina de baño, lavabo, sótano mojado o cerca de una alberca, etc. 6. El aparato eléctrico debe ser usado únicamente con carritos o pedestales que sean recomendados por el fabricante. 7. El aparato eléctrico debe ser montado a la pared o al techo sólo como sea recomendado por el fabricante. 8. Servicio—El usuario
ملخص المحتوى في الصفحة رقم 5
NOM Statement 17. Cuidado debe ser tomado de tal manera que objectos liquidos no sean derramados sobre la cubierta u orificios de ventilación. 18. Servicio por personal calificado deberá ser provisto cuando: A: El cable de poder o el contacto ha sido dañado; u B: Objectos han caído o líquido ha sido derramado dentro del aparato; o C: El aparato ha sido expuesto a la lluvia; o D: El aparato par ece no operar normalmente o muestra un cambio en su desempeño; o E: El aparato ha s
ملخص المحتوى في الصفحة رقم 6
Safety Instructions Safety Instructions For reliable and safe long-term operation of your ServSwitch DKM FX, follow these guidelines: Installation • Only use in dry, indoor environments. • The ServSwitch DKM FX and the power supply units can get warm. Don’t put them in an enclosed space without any airflow. • Do not obscure ventilation holes. • Only use power supplies originally supplied with the pr oduct or manufacturer- approved replacements. Do not use a power supply if it appears to be de
ملخص المحتوى في الصفحة رقم 7
Table of Contents Chapter Page 1. Specifications .........................................................................................10 1.1 Interfaces .........................................................................................10 1.1.1 DVI-D Single Link ..................................................................10 1.1.2 USB HID ................................................................................10 1.1.3 RJ-45 (Network) ........................
ملخص المحتوى في الصفحة رقم 8
Table of Contents Chapter Page 2.6 Diagnostics and Status ....................................................................24 2.6.1 Status LEDs ............................................................................24 2.6.2 Port Status ............................................................................ 30 2.6.3 Network Status .................................................................... 33 2.6.4 Firmware Status ............................................
ملخص المحتوى في الصفحة رقم 9
Table of Contents Chapter Page 4.9.2 Saving of Configurations (Internal) ........................................91 4.9.3 Loading of Configurations (Internal) ......................................93 4.9.4 Saving of Configurations (External) ...................................... 95 4.9.5 Loading of Configurations (External) .................................... 96 4.10 Export and Import Options ...........................................................97 4.10.1 Export Optio
ملخص المحتوى في الصفحة رقم 10
Chapter 1: Specifications 1. Specifications 1.1 Interfaces 1.1.1 DVI-D Single Link The video interface supports the DVI-D protocol. All signals that comply with DVI-D single-link standard can be transmitted. This includes, for example, monitor resolutions such as 1920 x 1200 @ 60 Hz, Full HD (1080p), or 2K HD (up to 2048 x 1152). Data rate is limited to 165 MPixel/s. 1.1.2 USB HID Devices with USB HID interface support a maximum of two devices with USB HID protocol. Each USB HID port provid
ملخص المحتوى في الصفحة رقم 11
Chapter 1: Specifications 1.1.4 RS-232 (Serial) The communication takes place with a transmission speed of up to 115.2 kbps, regardless of the file format. The transmission takes place with eight data bits and a stop bit, but without a parity bit. Limited hardware handshake (DSR) is possible. 1.1.5 RJ-45 (Interconnect) CATx device communication requires a 1000BASE-T connection. Connector wiring must comply with EIA/TIA-568-B (1000BASE-T), with RJ-45 connectors at both ends. All four wire pair
ملخص المحتوى في الصفحة رقم 12
Chapter 1: Specifications Table 1-1. CATx interconnect cable. Cable Type Description This S/UTP (CAT5e) cable confoms to EIA/TIA-568-B. CATx solid-core 24 AWG cable Uses four pairs of 24 AWG wires. Connects according to EIA/TIA-568-B (1000BASE-T). This S/UTP (CAT5e) cable confoms to EIA/TIA-568-B. CATx solid-core 26/8 AWG cable Uses four pairs of 26/8 AWG wires. Connects according to EIA/TIA-568-B (1000BASE-T). NOTE: You can use use type 26/8 AWG flexible cables (patch cables), but the
ملخص المحتوى في الصفحة رقم 13
Chapter 1: Specifications Table 1-4. Maximum acceptable fiber cable length. Cable Type Distance Single-mode 9-µm 32,800 ft. (10,000 m) Multimode 50-µm (OM3) 3280 ft. (1000 m) Multimode 50-µm 1300 ft. (400 m) Multimode 62.5µm 650 ft. (200 m) NOTE: If you use single-mode SFPs with multimode fiber optic cable, you can double the maximum acceptable cable length. Type of Connector The fiber cable uses LC connectors. 1.2.3 Coaxial NOTE: A point-to-point connection is necessary. Table 1-5. Coaxial i
ملخص المحتوى في الصفحة رقم 14
Chapter 1: Specifications 1.3 Supported Peripherals You can use the KVM extenders described in Tables 1-7 and 1-8 with the ServSwitch DKM FX: Table 1-7. KVM extender with CATx connection. Product Code Description ACX1T-11-C KVM CPU unit, single-head, 2x USB HID ACX1R-11-C KVM CON unit, single-head, 2x USB HID ACX1T-11V-C KVM CPU unit, single-head, DVI-I input (VGA), 2x USB HID ACX1R-11V-C KVM CON unit, single-head, IR receiver, 2x USB HID Table 1-8. KVM extender with fiber (single-mode) connect
ملخص المحتوى في الصفحة رقم 15
Chapter 1: Specifications Table 1-9. DVI-D single-link connector pinout. Pin Signal Pin Signal Pin Signal 1 T.M.D.S. data 2- 9 T.M.D.S. data 1- 17 T.M.D.S. data 0- 2 T.M.D.S. data 2+ 10 T.M.D.S. data 1+ 18 T.M.D.S. data 0+ 3 T.M.D.S. data 2 GND 11 T.M.D.S. data 1 GND 19 T.M.D.S. data 0 GND 4 Not connnected 12 Not connected 20 Not connected 5 Not connected 13 Not connected 21 Not connected 6 DDC input (SCL) 14 +5 VDC high impedance 22 T.M.D.S. GND 7 DDC output (SDA) 15 GND 23 T.M.D.S. clock+ 8 I
ملخص المحتوى في الصفحة رقم 16
Chapter 1: Specifications Table 1-12. RJ-45 connector. Picture Pin Signal Color Signal 1 D1+ 5 Not connected 2 D1- 6 D2- 3 D2+ 7 Not connected 4 Not connected 8 Not connected 1.4.2 I/O Board CATx Table 1-13. RJ-45 CATx connector. Picture Pin Signal Color Signal 1 D1+ 5 D3- 2 D1- 6 D2- 3 D2+ 7 D4+ 4 D3+ 8 D4- 1.4.3 I/O Board SFP Table 1-14. RJ-45 connector. Picture Diode Signal 1 Data OUT 2 Data IN 1.4.4 I/O Board SDI Table 1-15. RJ-45 connector. Picture Pin Signal 1 Data In 2 GND Page 16 724-746
ملخص المحتوى في الصفحة رقم 17
Chapter 1: Specifications 1.5 Power Supply Power — All models: Voltage: 100–240 VAC, 50–60 Hz; ACX288, ACX288-PS: 202 W max. without I/O boards; ACX160, ACX160-PS: 188 W max. without I/O boards; ACX080, ACX080-PS: 99 W max. without I/O boards; ACX048: 94 W max. without I/O boards; I/O boards (ACXI08-C, ACXI08-SM, ACXI08-SPF): 13 W max. 1.6 Environmental Conditions Temperature Tolerance — +41 to +113° F (+5 to +45° C) Storage Temperature — -13 to +140° F (-25 to +60° C) Relative Humidit
ملخص المحتوى في الصفحة رقم 18
Chapter 2: Overview 2. Overview 2.1 Description 2.1.1 Application The ServSwitch DKM FX is used to establish connections from consoles (monitor, keyboard, mouse, and other peripheral devices) to various sources (computer, CPU). In a maximum configuration, up to 288 independent ports can be defined and switched either as a console or a CPU. The ServSwitch DKM FX is mainly specified for the use with extenders that are able to transmit video, KVM, and USB 2.0 signals. You can also use it as a v
ملخص المحتوى في الصفحة رقم 19
Chapter 2: Overview 2.2 System Overview A ServSwitch DKM FX system consists of a ServSwitch DKM FX and, for KVM applications, one or more CPU units/CON units. The ServSwitch DKM FX is connected to the CPU units/CON units by interconnect cables or is connected directly to the video devices when used as a video matrix. The CPU units connect directly to the sources (computer, CPU), using the included cables. Monitor(s), keyboard, and mouse connect to the CON units. The ServSwitch DKM FX and th
ملخص المحتوى في الصفحة رقم 20
Chapter 2: Overview See Section 3.2 for installation examples. 2.3 Available Products Table 2-3. Available products. Number Description ServSwitch DKM FX ACX048 ServSwitch DKM FX 48-port with control card and power supply ACX080 ServSwitch DKM FX 80-port with control card and power supply ACX160 ServSwitch DKM FX 160-port with control card and power supply ACX288 ServSwitch DKM FX 288-port with control card and power supply Accessories ACXIO8-C 8-port CATx input/output (I/O) module ACXIO8-SM 8-p