Copyright © 2009 Sun Microsystems, Inc., 4150 Network Circle, Santa Clara, California 95054, U.S.A. All rights reserved. This distribution may include materials developed by third parties. Parts of the product may be derived from Berkeley BSD systems, licensed from the University of California. UNIX is a registered trademark in the U.S. and in other countries, exclusively licensed through X/Open Company, Ltd. Sun, Sun Microsystems, the Sun logo, Netra, Solaris, SunVTS and the Netra logo are trad
ملخص المحتوى في الصفحة رقم 3
Contents Preface xi 1. Overview 1–1 1.1 Features of the ARTM-HD 1–2 1.2 PICMG Standards Compliance 1–3 1.2.1 Maximum Power Dissipation 1–3 1.2.2 Airflow Cooling Requirements 1–3 1.2.3 Pressure Drop Rates 1–4 1.3 ARTM-HD Component Diagram 1–5 1.4 I/O Interfaces 1–6 1.5 Hard Disk Drives 1–8 1.6 Hard Disk Drive Controller 1–8 1.7 External SAS Connectors 1–9 1.8 LEDs 1–10 1.9 Software Support 1–12 1.10 Part Number, Serial Number, and FC Address Labels 1–13 2. Installation and Service 2–1 2.1 About I
ملخص المحتوى في الصفحة رقم 4
2.3 Removing the ARTM-HD 2–9 2.4 Installing a Hard Disk Drive 2–11 2.5 Removing a Hard Disk Drive 2–11 2.6 Changing the OOS LED Color 2–12 3. Disk Management 3–1 3.1 RAID Support 3–2 3.2 SAS BIOS Overview 3–2 3.3 Starting the SAS BIOS Configuration Utility 3–3 3.4 Creating a RAID 0 Volume 3–4 3.5 Creating a RAID 1 Volume 3–5 3.6 Creating a RAID 1E Volume 3–6 3.7 Viewing RAID Volume Properties 3–7 3.8 Synchronizing an Array 3–8 3.9 Activating an Array 3–8 3.10 Deleting an Array 3–9 3.11 Locating
ملخص المحتوى في الصفحة رقم 5
4.2.5 Module Management Controller 4–3 4.2.6 FRU PROM 4–4 4.3 Connectors and Pin Assignments 4–4 4.3.1 I/O Connectors 4–5 4.3.1.1 Ethernet Port 4–5 4.3.1.2 Serial Port 4–6 4.3.1.3 SAS Connectors 4–7 4.3.2 Zone 3 Connectors 4–8 Index Index–1 Contents v
ملخص المحتوى في الصفحة رقم 6
vi Netra CP32x0 SAS Storage Advanced Rear Transition Module HD User’s Guide • January 2009
ملخص المحتوى في الصفحة رقم 7
Figures FIGURE 1-1 Netra CP32x0 ARTM-HD Components 1–5 FIGURE 1-2 Relationship of the Blade Server, ATCA Midplane, and ARTM-HD 1–6 FIGURE 1-3 Connecting to an External Disk Array 1–9 FIGURE 1-4 Connecting to Another ARTM 1–10 FIGURE 1-5 LEDs 1–11 FIGURE 1-6 ARTM-HD Identification Labels 1–13 FIGURE 2-1 Installing the Blade Server and ARTM-HD Into the ATCA Shelf 2–3 FIGURE 2-2 Injector/Ejector Latch and Locking Screw 2–5 FIGURE 2-3 Holding the ARTM-HD During Installation 2–6 FIGURE 2-4 Inserting
ملخص المحتوى في الصفحة رقم 8
viii Netra CP32x0 SAS Storage Advanced Rear Transition Module HD User’s Guide • January 2009
ملخص المحتوى في الصفحة رقم 9
Tables TABLE 1-1 Airflow Cooling Requirements 1–3 TABLE 1-2 Pressure Drop Rates 1–4 TABLE 1-3 Netra CP32x0 ARTM-HD I/O Configurations 1–7 TABLE 1-4 LED Descriptions 1–11 TABLE 4-1 Ethernet Port Connector Pin Assignments 4–5 TABLE 4-2 Serial Port Connector Pin Assignments 4–6 TABLE 4-3 External SAS Connector Pin Assignments 4–7 TABLE 4-4 J31 Connector Pin Assignments 4–9 TABLE 4-5 J32 Connector Pin Assignments 4–9 TABLE 4-6 J33 Connector Pin Assignments 4–10 ix
ملخص المحتوى في الصفحة رقم 10
x Netra CP32x0 SAS Storage Advanced Rear Transition Module HD User’s Guide • January 2009
ملخص المحتوى في الصفحة رقم 11
Preface The Netra CP32x0 SAS Storage Advanced Rear Transition Module HD (ARTM-HD) User’s Guide provides installation instructions and hardware specifications for the Netra™ CP32x0 SAS Storage Advanced Rear Transition Module HD (ARTM-HD). This manual is written for system integration engineers, field applications and service engineers, and others involved in the integration of this module into Netra Advanced Telecommunications Computing Architecture (ATCA) systems. The system designer is responsi
ملخص المحتوى في الصفحة رقم 12
Using UNIX Commands ® This document might not contain information about basic UNIX commands and procedures such as shutting down the system, booting the system, and configuring devices. Refer to the following for this information: ■ Software documentation that you received with your system ■ Solaris™ Operating System documentation, which is at: http://docs.sun.com/ Shell Prompts Shell Prompt C shell machine-name% C shell superuser machine-name# Bourne shell and Korn shell $ Bourne shell and Korn
ملخص المحتوى في الصفحة رقم 13
Typographic Conventions * Typeface Meaning Examples AaBbCc123 The names of commands, files, Edit your.login file. and directories; on-screen Use ls -a to list all files. computer output % You have mail. AaBbCc123 What you type, when contrasted % su with on-screen computer output Password: AaBbCc123 Book titles, new words or terms, Read Chapter 6 in the User’s Guide. words to be emphasized. These are called class options. Replace command-line variables You must be superuser to do this. with real
ملخص المحتوى في الصفحة رقم 14
Related Documentation The following table lists the documentation for this product. Except for the Important Safety Information for Sun Hardware Systems, all the documents listed are available online at: http://docs.sun.com/app/docs/prod/cp32x0.sas?l=en#hic Application Title Part Number Format Location Getting Netra CP32x0 SAS Storage 820-0460 Printed Shipping kit Started Advanced Rear Transition Module PDF Online HD (ARTM-HD) Getting Started HTML Online Guide Latest Netra CP32x0 Advanced Rear 8
ملخص المحتوى في الصفحة رقم 15
Documentation, Support, and Training Sun Function URL Documentation http://www.sun.com/documentation/ Support http://www.sun.com/support/ Training http://www.sun.com/training/ Third-Party Web Sites Sun is not responsible for the availability of third-party web sites mentioned in this document. Sun does not endorse and is not responsible or liable for any content, advertising, products, or other materials that are available on or through such sites or resources. Sun will not be responsible or lia
ملخص المحتوى في الصفحة رقم 16
xvi Netra CP32x0 SAS Storage Advanced Rear Transition Module HD User’s Guide • January 2009
ملخص المحتوى في الصفحة رقم 17
CHAPTER 1 Overview This chapter provides an overview of the features, configurations, and system requirements of the Netra CP32x0 SAS Storage Advanced Rear Transition Module HD (ARTM-HD). This chapter contains the following sections: ■ Section 1.1, “Features of the ARTM-HD” on page 1-2 ■ Section 1.2, “PICMG Standards Compliance” on page 1-3 ■ Section 1.3, “ARTM-HD Component Diagram” on page 1-5 ■ Section 1.4, “I/O Interfaces” on page 1-6 ■ Section 1.5, “Hard Disk Drives” on page 1-8 ■ Section 1.
ملخص المحتوى في الصفحة رقم 18
1.1 Features of the ARTM-HD The Netra CP32x0 SAS Storage Advanced Rear Transition Module HD (ARTM-HD) ® is a fully compatible, carrier-grade Advanced Telecom Computing Architecture (ATCA) ARTM for ATCA blade servers designed to be compatible with the AdvancedRTM specification. The ARTM-HD is not compatible with ATCA cards that do not comply with this specification. The 6 rack unit (6U) form factor, single-slot ARTM supplies either single or dual SAS hard disk drives, and rear I/O connections tha
ملخص المحتوى في الصفحة رقم 19
1.2 PICMG Standards Compliance ® The ARTM-HD is fully compliant with the PICMG 2.0 Revision 3.1 specification. 1.2.1 Maximum Power Dissipation The maximum power dissipation is 25 Watts. 1.2.2 Airflow Cooling Requirements TABLE 1-1 lists the airflow cooling requirements based on a maximum power of 25W, which is the only power level available on this ARTM-HD. TABLE 1-1 Airflow Cooling Requirements 3 Meters Cubed Per Minute (M /min) Feet Cubed Per Minute (CFM) 25 28 40 55 25 28 40 55 0.07 0.07 0.14
ملخص المحتوى في الصفحة رقم 20
1.2.3 Pressure Drop Rates TABLE 1-2 lists the pressure drop rates for the ARTM-HD. TABLE 1-2 Pressure Drop Rates Volumetric Volumetric Pressure Pressure Flow Rate Flow Rate Drop Drop 3 CFM M /min Pascal Inches H 0 2 1 0.03 0.5 0.002 2 0.06 1.24 0.005 3 0.08 2.48 0.010 4 0.11 4.96 0.020 5 0.14 6.2 0.025 6 0.17 8.68 0.035 7 0.20 11.66 0.047 8 0.23 15.38 0.062 9 0.25 19.1 0.077 10 0.28 23.57 0.095 1-4 Netra CP32x0 SAS Storage Advanced Rear Transition Module HD User’s Guide • January 2009