ملخص المحتوى في الصفحة رقم 1
RAV-SM1100AT-E/RAV-SM1400AT-E
RAV-SM1100UT-E/RAV-SM1400UT-E
R410A
PRINTED IN JAPAN, Aug., 2003 ToMo
ملخص المحتوى في الصفحة رقم 2
ADOPTION OF NEW REFRIGERANT This Air Conditioner is a new type which adopts a new refrigerant HFC (R410A) instead of the conventional refrigerant R22 in order to prevent destruction of the ozone layer. WARNING Cleaning of the air filter and other parts of the air filter involves dangerous work in high places, so be sure to have a service person do it. Do not attempt it yourself. The cleaning diagram for the air filter is there for the service person, and not for the customer. RAV-SM1100AT-E RAV-
ملخص المحتوى في الصفحة رقم 3
Outdoor Unit –––––––––––––––––––––––– RAV-SM1100AT-E/RAV-SM1400AT-E INSTALLATION MANUAL 1 PRECAUTIONS FOR SAFETY.................................... 1 5 EVACUATING ............................................................... 9 2 ACCESSORY AND REFRIGERANT ........................... 3 6 ELECTRICAL WORK ................................................. 11 3 SELECTION OF INSTALLATION ................................ 3 7 FINAL INSTALLATION CHECKS .............................. 12 4 REFRIGERANT P
ملخص المحتوى في الصفحة رقم 4
1 PRECAUTIONS FOR SAFETY • Ensure that all Local, National and International regulations are satisfied. Read this “PRECAUTIONS FOR SAFETY” carefully before Installation. The precautions described below include the important items regarding safety. Observe them without fail. After the installation work, perform a trial operation to check for any problem. Follow the Owner’s Manual to explain how to use and maintain the unit to the customer. Turn off the main power supply switch (or breake
ملخص المحتوى في الصفحة رقم 5
After unpacking the unit, examine it carefully if there are possible damage. Do not install in a place that might increase the vibration of the unit. To avoid personal injury (with sharp edges), be careful when handling parts. Perform installation work properly according to the Installation Manual. Inappropriate installation may result in water leakage, electric shock or fire. When the air conditioner is installed in a small room, provide appropriate measures to ensure that the concent
ملخص المحتوى في الصفحة رقم 6
2 ACCESSORY AND REFRIGERANT Accessory and Installation Parts Refrigerant Piping Piping kit used for the conventional refrigerant cannot be used. Use copper pipe with 0.8 mm or more thickness for 1 3 Ø9.5 mm. Outdoor unit Installation manual x 1 Protective bush Use copper pipe with 1.0 mm or more thickness for Ø15.9 mm. Drain nipple Flare nut and flare works are also different from those 2 4 of the conventional refrigerant. Take out the flare nut Guard material for attached to the main u
ملخص المحتوى في الصفحة رقم 7
500 Installation Place Necessary Space for Installation A place which provides a specified space around the Obstacle at rear side outdoor unit. A place where the operation noise and discharged air are not given to your neighbors. 1. Single unit installation A place that is not exposed to a strong wind. A place that does not block a passage. When the outdoor unit is installed in an elevated position, be sure to secure its feet. There must be sufficient space for c
ملخص المحتوى في الصفحة رقم 8
3 SELECTION OF INSTALLATION Installation of Outdoor Unit Before installation, check strength and horizontality of the base so that abnormal sound does not generate. 1000 or more According to the following base diagram, fix the base firmly with the anchor bolts. (Anchor bolt, nut: M10 x 4 pairs) 150 600 150 430 Obstacles at both front and rear sides Drain hole Open the upper side and both right and left sides. The height of obstacle at both front and rear si
ملخص المحتوى في الصفحة رقم 9
Optional Installation Parts (Local Procure) Knockout of Pipe Cover Parts name Q’ty Refrigerant piping A Liquid side : Ø9.5 mm Each one Gas side : Ø15.9 mm Pipe insulating material B 1 (polyethylene foam, 6 mm thick) Rear direction C Putty, PVC tapes Each one Pipe cover Side direction Front direction Down direction Refrigerant Piping Connection CAUTION TAKE NOTICE THESE IMPORTANT 4 POINTS BELOW FOR PIPING WORK 1. Keep dust and moisture away from inside the Knockout procedure connecting pipes. T
ملخص المحتوى في الصفحة رقم 10
3 SELECTION OF INSTALLATION In order to avoid the force applied to on the connect- How to remove the front panel ing section, be sure to fix the cables to the cord 1. Remove screws of the front panel. clamps provided on the pipe valve fixing plate and the electric parts box. 2. Pull the front panel downward. Removing the front panel, the electric parts appear at Electric parts box Front panel the front side. The metal pipes are attachable to the piping holes. If the size of the used power pip
ملخص المحتوى في الصفحة رقم 11
Tightening of Connecting Part REQUIREMENT (Unit: N•m) 1. Do not put the spanner on the cap. The valve may be broken. Outer dia. of copper pipe Tightening torque 2. If applying excessive torque, the nut may be 6.4 mm (diam.) 14 to 18 (1.4 to 1.8 kgf•m) broken according to some installation conditions. 9.5 mm (diam.) 33 to 42 (3.3 to 4.2 kgf•m) 12.7 mm (diam.) 50 to 62 (5.0 to 6.2 kgf•m) • After the installation work, be sure to check gas leak of connecting part of the pipes with nitrogen. 15.
ملخص المحتوى في الصفحة رقم 12
5 EVACUATING Air Purge This air conditioner can be installed up to the connecting pipe length and height difference in the following table. Height difference (m) Max. connecting Hexagonal wrench size pipe length (m) Outdoor unit at upper side Outdoor unit at lower side 50 30 15 4 mm With respect to the preservation of terrestrial environment, adopt “Vacuum pump” for air purge (Evacuate air in the connecting pipes) when installing the unit. • Do not discharge the refrigerant gas to the atmosphere
ملخص المحتوى في الصفحة رقم 13
Handle position Compound pressure gauge Pressure gauge –101kPa (–76cmHg) Manifold valve Handle Lo Handle Hi (Keep fully closed) Charge hose (For R410A only) Charge hose Service port (For R410A only) Handle (Valve core (Setting pin)) Vacuum pump adapter for counter-flow prevention Closed completely Opened fully (For R410A only) Vacuum *1. Use the vacuum pump, vacuum pump adapters, pump and gauge manifold referring to the manuals Packed valve at gas side attached to each tool before using them.
ملخص المحتوى في الصفحة رقم 14
6 ELECTRICAL WORK For the air conditioner that has no power cable, connect Stripping length power cord and connecting cable a power cable as mentioned below. Model RAV- SM1100AT-E SM1400AT-E LN 10 10 12 3 220 – 240 V Power supply 10 10 Single phase 50 Hz Maximum running current 22.0 A 22.8 A 50 40 40 30 Installation fuse rating 25 A (D type ) H07 RN-F or 245 IEC 66 Earth line Earth line (mm) Power cable 2 (2.5 mm or more) Connecting Power cable cable CAUTION • Wrong wiring may cause a bu
ملخص المحتوى في الصفحة رقم 15
7 FINAL INSTALLATION CHECKS Check and Test Operation For R410A, use the leak detector exclusively manufactured for HFC refrigerant (R410A, R134a, etc.). The conventional leak detector for HCFC refrigerant (R22, etc.) cannot be used because its sensitivity for HFC * refrigerant lowers to approx. 1/40. • Pressure of R410A is approx. 1.6 times higher than that of R22. If installation work is incompletely finished, a gas leakage may occur when pressure rises during operation. Therefore, be sure to t
ملخص المحتوى في الصفحة رقم 16
7 FINAL INSTALLATION CHECKS Changes in the product and components Installation/Servicing Tools In the case of an air conditioner using R410A, in order to prevent any other refrigerant from being charged acciden- tally, service port diameter of the outdoor unit control valve (3 way valve) has been changed. (1/2 UNF 20 threads per inch) • In order to increase the pressure resisting strength of the refrigerant piping flare processing diameter and size of opposite side of flare nuts has been changed
ملخص المحتوى في الصفحة رقم 17
ACCESSORIES (SOLD SEPARATELY) Remote controller Standard 4-way cassette panel optional parts PRECAUTIONS FOR SAFETY WARNING WARNINGS ABOUT INSTALLATION • Make sure to ask the qualified installation professional in electric work to install the air conditioner. If the air conditioner is inappropriate installed by yourself, it may cause water leak, electric shock, fire, and so on. Be sure to provide grounding. Do not connect ground wires to gas pipes, water pipes, lightning rods or ground wires
ملخص المحتوى في الصفحة رقم 18
CAUTION CAUTIONS ABOUT INSTALLATION Be sure to confirm the following cautions. Certainly lay the drain hose for perfect draining. Bad drainage may cause flooding in the house and getting furniture wet. Make sure to connect the air conditioner to an exclusive power supply of the rated voltage, otherwise the unit may break down or cause a fire. Do not install the unit in a place where inflammable gas may leak. If inflammable gas accumulates around the unit, it may cause a fire. CAUTIONS AB
ملخص المحتوى في الصفحة رقم 19
PARTS NAME Indoor unit Button Earth screw Button to open/close the Provided in the electric parts suction port box Discharge flap of discharge port Change the direction of the air to be discharged according to cool/heat mode. Air filter Removes dust or trash. Suction air port (Provided on the suction port.) The air in the room is sucked in from this port. Projection of air filter Outdoor unit Remote controller Air inlet (Side and rear) REMOTE CONTROLLER Air outlet Pipes and electric wires 1
ملخص المحتوى في الصفحة رقم 20
PARTS NAME OF REMOTE CONTROLLER Display section CODE No. In the display example, all indicators are displayed for the explana- SET DATA UNIT No. Display tion. section SETTINGTEST R.C. No. In reality only, the selected contents are indicated. When turning on the leak breaker at the first time, [SET DATA] flashes on the display part of the remote controller. Operation While this display is flashing, the model is being automatically section UNIT confirmed. Accordingly, wait for a while after [S