ملخص المحتوى في الصفحة رقم 1
Models
SG-WAC-10ESE-C
SG-WAC-12ESE-C
Electronic Window Air Conditioner
Operating Instructions
ملخص المحتوى في الصفحة رقم 2
ملخص المحتوى في الصفحة رقم 3
Thank you for choosing a Soleus Air powered by Gree Air Conditioner. This owner’s manual will provide you with valuable information necessary for the proper care and maintenance of your new product. Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new air conditioner. For your own records, please attach a copy of your sales receipt to this manual. Also, write the store name/location, date purchased, and seria
ملخص المحتوى في الصفحة رقم 4
ELECTRICAL REQUIREMENTS The electrical ratings for your air conditioner are listed on the model and serial number label located on the front left side of the unit (when facing the front). Specific electrical requirements are listed in the chart below. Follow the requirements below for the type of plug on the power supply cord. Wiring Requirements Power Supply Cord • 115 volt (103.5 min.—126.5 Electrical Shock Hazard max) Plug into a grounded 3 prong outlet. • 0-12 amps Do not r
ملخص المحتوى في الصفحة رقم 5
PACKING LIST Packing List: • Sash Lock (1) • Window Air Conditioner • Window Sash Seal • Remote Control • 3/4” Screw for Window Locking Bracket & Accordion • AAA Batteries (2) Panels, and sash lock (6) • Top Mounting Rail • Foam Top Window Gasket • Top Mounting Rail Seal Strip • Owner’s Manual • Lock Frame (2) • Accordion Panels (Left & Right) 4
ملخص المحتوى في الصفحة رقم 6
SPECIFICATIONS • Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode. • Power consumption is measured when the fan runs at the highest speed setting. • These specifications are for reference only. For actual data, please refer to the rating label on the back of the unit. Model SG-WAC-10ESE-C SG-WAC-12ESE-C Power Supply (Ph/V/Hz) 1/115/60 1/115/60 Rated Cooling Capacity (BTU/h) 10,000 12,000 Cooling Power Input (Watts) 940 11 30 Rat
ملخص المحتوى في الصفحة رقم 7
INSTALLATION & ASSEMBLY INSTRUCTIONS Some assembly is required for your new air conditioner. Please read and follow these instructions carefully. 1. This air conditioner is designed to be installed in a standard double-hung window with a window width FIG. 1 between 22” and 36” (559 mm - 914 mm). 2. The air conditioner can be installed without the 22 " to 3 6" accordion panels to fit in a narrow window opening. 559mm to 914mm See the window dimensions. 15 2/5" 3. The Lower Sash
ملخص المحتوى في الصفحة رقم 8
Mounting Hardware Qty. 3/4"screws 6 lock frame 2 FIG. 3A B. Slide the free end (“I”section) of the panel into the cabinet as shown in Figures 3A, 3B & 4. Slide the sash lock 1 panel down. Be sure to leave enough space to slip the top and bottom of the frame into the rails on the cabinet. FIG. 3B TOOLS NEEDED: Phillips Screw Driver Drill (If pilot holes are needed) CAUTION When handling unit, be careful to avoid cuts from sharp metal edges and aluminum fins on front and rear coils. FIG. 4 How to
ملخص المحتوى في الصفحة رقم 9
Keep a firm grip on the air conditioner, carefully Drive 3/4” (19mm) locking screws place the unit into the window opening so the 2 through frame holes into window sash 5 bottom of the air conditioner frame is against the (FIG. 10/11). window sill (FIG. 6 & FIG. 6A). Carefully close the window behind the top rail of the unit. FIG. 10 FIG. 6 FIG. 11 FIG. 6A To secure lower sash in place, attach right 6 angle sash lock with 3/4” (19 mm) screw Extend the side panels out against the window as shown
ملخص المحتوى في الصفحة رقم 10
If AC is Blocked by Storm AIR CONDITIONER USE Window Operating your air conditioner properly helps you to obtain the best possible results. Add wood as shown in FIG. 14, or remove storm This section explains proper air conditioner operation. window before air conditioner is installed. IMPORTANT: If you turn off the air conditioner, wait at least 3 minutes before turning it back on. This prevents the air conditioner FIG. 14 from blowing a fuse or tripping a circuit breaker. SASH Do not try to ope
ملخص المحتوى في الصفحة رقم 11
USING YOUR AIR CONDITIONER 3. Temperature Set: Use these buttons on the con- Electronic Control Panel & Remote Control trol panel and remote to increase or decrease the Set Temperature (the desired room temperature) in cooling,energy saver and dry mode. The SET NOTE: This display always shows the room temperature in Fan Mode except when setting the Set temperature or the Timer. light will light up when setting the temperature 4. Timer Set: Use these buttons on the control When the
ملخص المحتوى في الصفحة رقم 12
OPERATING YOUR AIR CONDITIONER REMOTE CONTROL 5. FAN - Press the FAN button to turn change the FAN options. You can choose between three speeds and auto mode. The fourth fan option is only available in cooling and energy saver modes. 6. IFEEL MODE - Press the IFEEL button to change the thermostat sensor from the air conditioner to the remote location. The air con- ditioner will cool the area depending on the location and set temperature of the remote control. Take the remote
ملخص المحتوى في الصفحة رقم 13
OPERATING YOUR AIR CONDITIONER REMOTE CONTROL 9. LOCK/UNLOCK - Press the “+” and “—” buttons simultaneously to lock and unlock the remote control. When the remote is locked, none of the functions or setting can be changed using the remote. 10. F° or C° - To switch between the F° or C° settings, press the MODE and “—” buttons a t the same time. 11. DISPLAY LIGHTS- Hold the “+” and FAN buttons to turn the lights on the display ON or OFF. This can be done when the unit is on or off.
ملخص المحتوى في الصفحة رقم 14
USING YOUR AIR CONDITIONER (Cont.) • Freezing Conditions: This is a cooling only air • Fan Only Mode: Use Fan Only mode at Low, conditioner. It is not designed for freezing outdoor Med, or High fan speed to provide air circulation conditions. It must not be used in freezing outdoor and filtering without cooling. Since fan only setting conditions. do not provide cooling, a Set temperature cannot be entered. The room temperature will appear in • Remote Control: To ensure
ملخص المحتوى في الصفحة رقم 15
Cabinet Cleaning CARE AND CLEANING To clean the air conditioner cabinet: Clean your air conditioner to keep it looking new and to minimize dust build up. • Unplug the air conditioner to prevent shock or a fire hazard. The cabinet and front panel of Air Filter Cleaning the air conditioner may be dusted with an oil- The air filter should be checked at least once free cloth or washed with a cloth dampened in every month to see if it needs cleaning. Trapped a solution of warm water and
ملخص المحتوى في الصفحة رقم 16
TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS The Air Conditioner will not start The air conditioner is unplugged • Make sure the air conditioner is plug is pushed completely into the outlet • Check the house fuse/circuit The fuse is blown/circuit breaker is breaker box and replace the fuse tripped. or reset the breaker. • The unit will automatically re-start Power Failure when power is restored. • There is a protective time delay (app
ملخص المحتوى في الصفحة رقم 17
TROUBLESHOOTING (CONT.) PROBLEM POSSIBLE CAUSES SOLUTIONS Water is dripping outside Hot and Humid weather. • This is normal Water is dripping inside the room The air conditioner is not correctly • For proper water drainage, make tilted outside. sure the air conditioner is slightly tilted downward from the front of the unit to the rear. Water collects in the base pan Moisture removed from the air is • This is normal for a short period in draining into the base pan. are
ملخص المحتوى في الصفحة رقم 18
Warranty Soleus International Inc. warrants the accompanying Soleus Air Air Conditioner to be free of defects in mate- rial and workmanship for the applications specified in its operation instruction for the period of parts specified below. 5 YEARS FOR COMPRESSOR 1 YEAR FOR OTHER COMPONENTS This warranty shall not apply to broken or marred cabinets, accessories, knobs, filters or routine maintenance. This warranty does not apply to uncrating, setup, installation, removal of the p
ملخص المحتوى في الصفحة رقم 19
ملخص المحتوى في الصفحة رقم 20