ملخص المحتوى في الصفحة رقم 1
TECHNICAL DATA
&
FILE NO.
SERVICE MANUAL
XH2672R / CH2672R, C2672R KH2672R / CH2672R, C2672R
XH3672R / CH3672R, C3672R KH3072R / CH3072R, C3072R
XH4272R / CH4272R, C4272R KH3672R / CH3672R, C3672R
KHH2672R / CH2672R
TH2672R / CH2672R, C2672R
TH3672R / CH3672R, C3672R UH2672R / CH2672R, C2672R
TH4272R / CH4272R, C4272R UH3672R / CH3672R, C3672R
THH2672R / CH2672R
THH3672R / CH3672R
SPLIT SYSTEM AIR CONDITIONER
Section
INDOOR MODEL No. PRODUCT CODE No. OUTDOOR MODEL No. PRODUCT CODE No.
1
XH267
ملخص المحتوى في الصفحة رقم 2
ملخص المحتوى في الصفحة رقم 3
Important When Installing Please Read Before Starting ............................................................................................. …In a Room This air conditioning system meets strict safety and operating Properly insulate any tubing run inside a room to prevent standards. As the installer or service person, it is an important “sweating” that can cause dripping and water damage to walls part of your job to install or service the system so it operates and floors. safely and effic
ملخص المحتوى في الصفحة رقم 4
Contents Section 1: SPECIFICATIONS ................................................................................................. I-1 1-1 Unit Specifications .......................................................................................... I-2 1-2 Major Component Specifications .................................................................. I-27 1-3 Other Component Specifications .................................................................. I-47 1-4 Dimensional data .........
ملخص المحتوى في الصفحة رقم 5
1. Specifications 1. SPECIFICATIONS 1-1 Unit Specifications ......................................................................................................... I-2 1-2 Major Component Specifications ............................................................................... I-27 1-3 Other Component Specifications ............................................................................... I-47 1-4 Dimensional data .....................................................................
ملخص المحتوى في الصفحة رقم 6
1. Specifications 1-1 Unit Specifications Wall-Mounted Type MODEL No. Indoor Unit KHH2672R Outdoor Unit CH2672R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Heating Capacity * [minimum~muximum] BTU / h 23,000 [9,500~23,000] 27,600 [8,000~27,600] (17˚F)** BTU / h 18,500 Moisture removal (High) Pints / h 7.4 Air circulation (H / M / L) 230 V CFM 540 / 460 / 380 External Static Pressure in. WG S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 15.9 10.3 ELECTRICAL RATINGS Voltage rating V 2
ملخص المحتوى في الصفحة رقم 7
1. Specifications 1-1 Unit Specifications Wall-Mounted Type MODEL No. Indoor Unit KH2672R Outdoor Unit CH2672R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Heating Capacity * [minimum~muximum] BTU / h 25,200 [9,500~25,200] 29,200 [8,000~29,200] (17˚F)** BTU / h 17,200 Moisture removal (High) Pints / h 8.1 Air circulation (H / M / L) 230 V CFM 559 / 475 / 390 External Static Pressure in. WG S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 14.9 10.2 ELECTRICAL RATINGS Voltage rating V 23
ملخص المحتوى في الصفحة رقم 8
1. Specifications 1-1 Unit Specifications Wall-Mounted Type MODEL No. Indoor Unit KH3072R Outdoor Unit CH3072R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Heating Capacity * [minimum~muximum] BTU / h 29,800 [9,500~29,800] 34,800 [8,000~34,800] (17˚F)** BTU / h 20,000 Moisture removal (High) Pints / h 9.7 Air circulation (H / M / L) 230 V CFM 840 / 740 / 620 External Static Pressure in. WG S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 15.0 9.0 ELECTRICAL RATINGS Voltage rating V 230
ملخص المحتوى في الصفحة رقم 9
1. Specifications 1-1 Unit Specifications Wall-Mounted Type MODEL No. Indoor Unit KH3672R Outdoor Unit CH3672R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Heating Capacity * [minimum~muximum] BTU / h 31,400 [9,500~31,400] 36,400 [8,000~36,400] (17˚F)** BTU / h 20,200 Moisture removal (High) Pints / h 10.0 Air circulation (H / M / L) 230 V CFM 830 / 710 / 590 External Static Pressure in. WG S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 15.9 9.0 ELECTRICAL RATINGS Voltage rating V 23
ملخص المحتوى في الصفحة رقم 10
1. Specifications 1-1 Unit Specifications Wall-Mounted Type MODEL No. Indoor Unit KH2672R Outdoor Unit C2672R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Capacity * [minimum~muximum] BTU / h 25,200 [9,500~25,200] (17˚F)** BTU / h Moisture removal (High) Pints / h 8.1 Air circulation (H / M / L) 230 V CFM 559 / 475 / 390 External Static Pressure in. WG S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 14.9 ELECTRICAL RATINGS Voltage rating V 230 208 Available voltage range V VAC 187 - 2
ملخص المحتوى في الصفحة رقم 11
1. Specifications 1-1 Unit Specifications Wall-Mounted Type MODEL No. Indoor Unit KH3072R Outdoor Unit C3072R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Capacity * [minimum~muximum] BTU / h 29,800 [9,500~29,800] (17˚F)** BTU / h Moisture removal (High) Pints / h 9.7 Air circulation (H / M / L) 230 V CFM 840 / 740 / 620 External Static Pressure in. WG S.E.E.R. BTU / Wh 15.0 ELECTRICAL RATINGS Voltage rating V 230 208 Available voltage range V VAC 187 - 253 Max. Running ampere
ملخص المحتوى في الصفحة رقم 12
1. Specifications 1-1 Unit Specifications Wall-Mounted Type MODEL No. Indoor Unit KH3672R Outdoor Unit C3672R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Capacity * [minimum~muximum] BTU / h 31,400 [9,500~31,400] (17˚F)** BTU / h Moisture removal (High) Pints / h 10.0 Air circulation (H / M / L) 230 V CFM 830 / 710 / 590 External Static Pressure in. WG S.E.E.R. BTU / Wh 15.9 ELECTRICAL RATINGS Voltage rating V 230 208 Available voltage range V VAC 187 - 253 Max. Running amper
ملخص المحتوى في الصفحة رقم 13
1. Specifications 1-1 Unit Specifications 4-Way Air Discharge Semi-Concealed Type MODEL No. Indoor Unit XH2672R Outdoor Unit CH2672R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Heating Capacity * [minimum~muximum] BTU / h 24,800 [9,500~24,800] 29,800 [8,000~29,800] (17˚F)** BTU / h 18,300 Moisture removal (High) Pints / h 8.1 Air circulation (H / M / L) 230 V CFM 710 / 530 / 450 External Static Pressure in. WG S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 14.1 10.5 ELECTRICAL RATING
ملخص المحتوى في الصفحة رقم 14
1. Specifications 1-1 Unit Specifications 4-Way Air Discharge Semi-Concealed Type MODEL No. Indoor Unit XH3672R Outdoor Unit CH3672R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Heating Capacity * [minimum~muximum] BTU / h 32,600 [9,500~32,600] 37,600 [8,000~37,600] (17˚F)** BTU / h 20,000 Moisture removal (High) Pints / h 10.6 Air circulation (H / M / L) 230 V CFM 1050 / 840 / 720 External Static Pressure in. WG S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 14.6 9.1 ELECTRICAL RATIN
ملخص المحتوى في الصفحة رقم 15
1. Specifications 1-1 Unit Specifications 4-Way Air Discharge Semi-Concealed Type MODEL No. Indoor Unit XH4272R Outdoor Unit CH4272R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Heating Capacity * [minimum~muximum] BTU / h 39,500 [9,500~39,500] 48,000 [8,000~48,000] (17˚F)** BTU / h 31,800 Moisture removal (High) Pints / h 12.6 Air circulation (H / M / L) 230 V CFM 1050 / 840 / 720 External Static Pressure in. WG S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 14.6 10.4 ELECTRICAL RATI
ملخص المحتوى في الصفحة رقم 16
1. Specifications 1-1 Unit Specifications 4-Way Air Discharge Semi-Concealed Type MODEL No. Indoor Unit XH2672R Outdoor Unit C2672R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Capacity * [minimum~muximum] BTU / h 24,800 [9,500~24,800] (17˚F)** BTU / h Moisture removal (High) Pints / h 8.1 Air circulation (H / M / L) 230 V CFM 710 / 530 / 450 External Static Pressure in. WG S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 14.1 ELECTRICAL RATINGS Voltage rating V 230 208 Available volta
ملخص المحتوى في الصفحة رقم 17
1. Specifications 1-1 Unit Specifications 4-Way Air Discharge Semi-Concealed Type MODEL No. Indoor Unit XH3672R Outdoor Unit C3672R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Capacity * [minimum~muximum] BTU / h 32,600 [9,500~32,600] (17˚F)** BTU / h Moisture removal (High) Pints / h 10.6 Air circulation (H / M / L) 230 V CFM 1050 / 840 / 720 External Static Pressure in. WG S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 14.6 ELECTRICAL RATINGS Voltage rating V 230 208 Available vol
ملخص المحتوى في الصفحة رقم 18
1. Specifications 1-1 Unit Specifications 4-Way Air Discharge Semi-Concealed Type MODEL No. Indoor Unit XH4272R Outdoor Unit C4272R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Capacity * [minimum~muximum] BTU / h 39,500 [9,500~39,500] (17˚F)** BTU / h Moisture removal (High) Pints / h 12.6 Air circulation (H / M / L) 230 V CFM 1050 / 840 / 720 External Static Pressure in. WG S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 14.6 ELECTRICAL RATINGS Voltage rating V 230 208 Available vol
ملخص المحتوى في الصفحة رقم 19
1. Specifications 1-1 Unit Specifications Concealed-Duct Type MODEL No. Indoor Unit UH2672R Outdoor Unit CH2672R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Heating Capacity * [minimum~muximum] BTU / h 24,000 [9,500~24,000] 28,600 [8,000~28,600] (17˚F)** BTU / h 17,100 Moisture removal (High) Pints / h 7.7 Air circulation (H / M / L) 230 V CFM 670 / 530 / 460 External Static Pressure in.WG 0.2:at shipment / 0.4:using jumper cable S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 14.0 9.
ملخص المحتوى في الصفحة رقم 20
1. Specifications 1-1 Unit Specifications Concealed-Duct Type MODEL No. Indoor Unit UH3672R Outdoor Unit CH3672R POWER SOURCE 230 - 208 V / 1 Phase / 60 Hz PERFORMANCE Cooling Heating Capacity * [minimum~muximum] BTU / h 31,200 [9,500~31,200] 36,200 [8,000~36,200] (17˚F)** BTU / h 20,200 Moisture removal (High) Pints / h 10.0 Air circulation (H / M / L) 230 V CFM 670 / 530 / 460 External Static Pressure in. WG 0.24:at shipment / 0.4:using jumper cable S.E.E.R. / H.S.P.F. (Region 4) BTU / Wh 13.9