ملخص المحتوى في الصفحة رقم 1
ITB/ITCB
ICB/TWIN
®
Infusion Series
PROGRAMMING MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
41581.0002A 09/09 ©2009 Bunn-O-Matic Corporation
ملخص المحتوى في الصفحة رقم 2
BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 years parts and 1 year labor. 2) Electronic circuit and/or control boards: parts and labor for 3 years. 3) Compressors on refrigeration equipment: 5 years parts and 1 year labor. 4) Grinding burrs on coffee grinding equipment to grind coffee to meet original factory screen sieve analysis: parts and labor for 3 years or 30,000 po
ملخص المحتوى في الصفحة رقم 3
INTRODUCTION ITB This equipment will brew tea into an awaiting dispenser or reservoir. It is only for indoor use on a sturdy counter or shelf. The ITB uses recipe settings to brew tea. It has an LCD for digital readout and programming. The user is able to select regular or quick brew for tea programming. Other features include Pre-Infusion and Pulse Brew, quick and standard brew, Energy Savings mode, BUNNLink compatible, Freshness Timer, Sanitation Alert, and brew counters. Available in low
ملخص المحتوى في الصفحة رقم 4
PROGRAMMING THE BREWER ICB PROGRAMMING FUNCTIONS - FLOW CHART BREW LOCKOUT? NO DONE YES PROGRAMMING FUNCTIONS - LEVEL I PROGRAMMING FUNCTIONS - LEVEL 2 SET LANGUAGE? UNITS REVIEW RECIPES ASSIGN RECIPE NO YES METRIC DONE ENG NO YES NO YES SET NEW RECIPE? SET TEMP 200° READY DEGREE 5° ENABLE ADS? NO YES (-) DONE (+) (-) DONE (+) NO DONE YES ENABLE SANITATION ENABL ENER
ملخص المحتوى في الصفحة رقم 5
PROGRAMMING THE BREWER (cont.) ICB TWIN PROGRAMMING FUNCTIONS - FLOW CHART BREW LOCKOUT? NO DONE YES PROGRAMMING FUNCTIONS - LEVEL I PROGRAMMING FUNCTIONS - LEVEL 2 SET LANGUAGE? UNITS REVIEW RECIPES ASSIGN RECIPE NO YES METRIC DONE ENG NO YES NO YES SET NEW RECIPE? SET TEMP 200° READY DEGREE 5° ENABLE ADS? NO YES (-) DONE (+) (-) DONE (+) NO DONE YES ENABLE SANITATI
ملخص المحتوى في الصفحة رقم 6
ITB PROGRAMMING FUNCTIONS - FLOW CHART BREW LOCKOUT? NO DONE YES PROGRAMMING FUNCTIONS - LEVEL I PROGRAMMING FUNCTIONS - LEVEL 2 SET LANGUAGE? UNITS REVIEW RECIPES ASSIGN RECIPE NO YES METRIC DONE ENG NO YES NO YES MASTER TEMP 205° READY DEGREE 5° ENABLE ADS? ENABLE SANITATION (-) DONE (+) (-) DONE (+) NO DONE YES NO DONE YES ENABL ENERGYSAVR ENABLE FRESH TIMER XX REFILL
ملخص المحتوى في الصفحة رقم 7
ITCB PROGRAMMING FUNCTIONS - FLOW CHART BREW LOCKOUT? NO DONE YES PROGRAMMING FUNCTIONS - LEVEL I PROGRAMMING FUNCTIONS - LEVEL 2 SET LANGUAGE? UNITS REVIEW RECIPES ASSIGN RECIPE NO YES METRIC DONE ENG NO YES NO YES SET NEW RECIPE? MASTER TEMP 205° READY DEGREE 5° ENABLE ADS? NO YES (-) DONE (+) (-) DONE (+) NO DONE YES ENABLE SANITATION ENABL ENERGYSAVR ENABLE FRESH
ملخص المحتوى في الصفحة رقم 8
FACTORY DEFAULTS ICB ICB Twin ITCB ITB Brew Lockout Enabled Enabled Disabled Disabled Set Language English English English English Units English English English English Review Recipes √ √ √ √ Assign Recipes √ √ √ √ Set New Recipe √ √ √ X Set (Master) Temp 200° 200° 205° 205° Ready Degree 5° 5° 5° 5° Enable Ads Disabled Disabled Disabled D
ملخص المحتوى في الصفحة رقم 9
PROGRAMMING WITH RECIPE CARD NOT AVAILABLE ON ITB Using a RECIPE CARD to load recipes: The RECIPE CARD includes all the information needed READY TO BREW to set up that particular coffee/tea name. The informa- WATER TEMP XXX° tion from the RECIPE CARD is loaded into the brewer’s memory by holding the chip area up to the brewer’s POSITION CARD UNDER SENSOR COIL SENSING COIL. This information can include all the recipe settings for that particular name. These can all be loaded in seconds.
ملخص المحتوى في الصفحة رقم 10
PROGRAMMING WITH AD CARD NOT AVAILABLE ON ITB Using an AD CARD to load ADS: The information is loaded into the brewer’s memory by holding the chip area up to the brewer’s SENSING COIL. NOTE: Instructions to program the brewer are printed on the AD CARD. Procedure to program the AD: 1. Remove the funnel(s) if present. 2. Position the RECIPE CARD vertically, so that the top end of the CHIP is beneath the (Left on Twins) SENSING COIL (located on the underneath side of the front display pane
ملخص المحتوى في الصفحة رقم 11
PROGRAMMING THE BREWER PROGRAMMING FUNCTIONS - LEVEL 1 * BREW LOCKOUT This function allows the operator to prevent or allow brewing if the water temperature is less than the set READY temperature. Procedure for setting Brew Lockout: 1. To access this function screen press and hold the right hidden button. Release when the display reads: BREW LOCKOUT? NO DONE YES Press here Press here Press here for NO for DONE for YES 2. The YES or NO should be flashing. Select YES to prevent brewing if the wa
ملخص المحتوى في الصفحة رقم 12
PROGRAMMING THE BREWER (cont.) PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) * UNITS This function allows the operator to select if numeric settings are displayed in English or Metric units. Procedure for setting the Units: 1. Press and hold the right hidden button until the display reads SET LANGUAGE? Press and release the right hidden button until the display reads UNITS. The METRIC or ENG should be flashing. 2. Select METRIC to have settings displayed in Metric units. Select ENG for English units
ملخص المحتوى في الصفحة رقم 13
PROGRAMMING THE BREWER (cont.) PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) 3. Select SHOW. The screen will scroll through all the brew settings for that particular recipe. When finished, the display will return to the recipe name just viewed. 4. To see the settings again, select SHOW. To change settings, select MODIFY. Then the screen will display BREW OZ and a batch light will be blinking. 5. Using (-) or (+), set the amount of brew water to be dispensed for that batch size. 6. When finished, pr
ملخص المحتوى في الصفحة رقم 14
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) 9. If both batch sizes are correct, press YES. This will Setting Pulse Brew – EASY Pulse Brew advance to the DILUTE OZ (ITCB) or BYPASS % Range: Minimum: will adjust to the minimum time (ICB) required to brew that batch using the set brew volumes 10. Using (-) or (+), set the amount of dilution water for and flow rate for the sprayhead. Maximum – will adjust that particular batch size to be dispensed through depending on settings and will always be
ملخص المحتوى في الصفحة رقم 15
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) 34. When finished, press the other batch size and repeat Setting SWEET METER: Optional on ITCB step # 33. This function allows the operator to adjust the amount of sweetener added to the dilution water. The solenoid 35. When finished setting both batch sizes, press and release DONE. is pulsed on/off for the duration of the dilution cycle. 36. The display should now read LAST ON:. Adjust the Setting #1 will produce the least amount of sweetener LAST
ملخص المحتوى في الصفحة رقم 16
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) ICB ITB/ITCB REVIEW RECIPES REVIEW RECIPES NO YES NO YES NO NAME COFFEE TEA 1 MODIFY SHOW NEXT MODIFY SHOW NEXT BREW OZ: 64 BREW OZ: 76 (-) DONE (+) (-) DONE (+) % BYPASS: 20 DILUTE OZ: 320.0 (-) DONE (+) (-) DONE (+) SET PULSE BREW? DILUTE DELAY 00.0 NO YES (-) DONE (+) SET PULSE BREW? DRIP TIME: 0:30 SELECT METHOD (-) DONE (+) EAS
ملخص المحتوى في الصفحة رقم 17
PROGRAMMING THE BREWER (cont.) PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) * ASSIGN RECIPE to or disable BREW SWITCH(S) This function allows the operator to assign a recipe to ASSIGN RECIPE (or disable) each of the 3 brew switches (A, B, C). Any NO YES saved recipes listed under "REVIEW RECIPES" can be assigned to a brew switch. Only one recipe per brew switch is allowed. Procedure to select switch recipes ADVANCE TO SELECT RECIPE NEXT FUNCTION 1. Press and hold the right hidden switch until t
ملخص المحتوى في الصفحة رقم 18
PROGRAMMING THE BREWER (cont.) NOT AVAILABLE ON ITB PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) switch until the display reads SET LANGUAGE. * SET NEW RECIPE (COFFEE ONLY) Press and release the right hidden switch until the To set a new COFFEE recipe using a Smart Funnel display reads SET NEW RECIPE. and a G9-2T DBC or MHG Grinder: 4. Select YES. The display should read INSERT FUN- This function allows the operator to set BREW VOL- NEL WITH NEW NAME, then QUIT SETUP? These UMES, BYPASS %, PULS
ملخص المحتوى في الصفحة رقم 19
PROGRAMMING THE BREWER (cont.) PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) * SET TEMP - ICB (MASTER TEMP - ITCB) * ENABLE ADS This function allows the operator to adjust the brew This function allows the operator to choose whether water temperature in the tank. This also sets the hot or not to display an advertising message. An ad can be water faucet dispense temperature. saved to the brewer by either writing the ad using the programming commands, or by entering the ad into Procedure for settin
ملخص المحتوى في الصفحة رقم 20
PROGRAMMING THE BREWER (cont.) PROGRAMMING FUNCTIONS - LEVEL 2 (cont.) 12. Select DONE. The display should now read WRITE * ENABLE SANITATION BTM LINE?. This function allows the operator to enable the sanita- 13. To write the bottom line, select YES. tion function and set the time before a cleaning alert 14. To skip the bottom line, select NO. will be displayed. a. If neither a top nor bottom line was written, the display should now read ENABL SANITATION. Procedure for enabling sanitation: