8382
for
3 Gallon
and
5 Gallon
Plastic Bottles
Includes:
Installation
Operation
Use & Care
Servicing Instructions
Model 8382 Brewer
PRINTED IN UNITED STATES OF AMERICA
p/n 75611 Rev. E ECN-12597 M682 040914 cps
ملخص المحتوى في الصفحة رقم 2
WARRANTY STATEMENT All electrical equipment manufactured by BLOOMFIELD The prices charged by Bloomfield Industries for its products INDUSTRIES is warranted against defects in material and are based upon the limitations in this warranty. Seller’s obli- workmanship for a period of one year from original purchase gation under this warranty is limited to repair of defects with- or eighteen months from the date of shipment from our out charge by a Bloomfield Industries Authorize
ملخص المحتوى في الصفحة رقم 3
TABLE OF CONTENTS Thank You for purchasing this Bloomfield Industries appliance. WARRANTY STATEMENT xi SPECIFICATIONS 1 Proper installation, professional FEATURES & OPERATING CONTROLS 2 operation and consistent PRECAUTIONS & GENERAL INFORMATION 3 maintenance of this appliance will AGENCY APPROVAL INFORMATION 3 ensure that it gives you the very best performance and a long,
ملخص المحتوى في الصفحة رقم 4
FEATURES AND OPERATING CONTROLS Fig. 1 Features & Operating Controls 2
ملخص المحتوى في الصفحة رقم 5
PRECAUTIONS AND GENERAL INFORMATION WARNING: Electric Shock Hazard All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: Injury Hazard All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes. Failure could result in pr
ملخص المحتوى في الصفحة رقم 6
INSTALLATION INSTRUCTIONS READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION IMPORTANT: Unpack the unit. Inspect all components for completeness and To enable the installer to make condition. Ensure that all packing materials have been removed a quality installation and to from the unit. minimize installation time, the Verify that the Spray Head Gasket (#33) and Spray Disk (#34) following suggestions and tests are properly installed. should be done before the actual
ملخص المحتوى في الصفحة رقم 7
OPERATION START-UP WARNING: Personal Injury For initial start-up, or if the brewer has not been used for an extended period of time: 5 Gallon water bottle can weigh up to 50 pounds. Install bottle ♦ Be sure spray disk and brew gasket are properly installed carefully. Injury can result from in the brew head. improper lifting technique or ♦ Install a fresh bottle of water in the bottle ring. from attempting to lift a full bottle ♦ All
ملخص المحتوى في الصفحة رقم 8
OPERATION (continued) HI-LIMIT WATER HEATER THERMOSTAT Water temperature is sensed by a thermobulb inserted into the water tank. This temperature signal is fed to the thermostat, THERMOBULB which controls line power to the heating element. The setpoint temperature is adjustable at the HEATER ELEMENT thermostat. THERMOSTAT The element is protected from over- temperature by a hi-limit thermostat. Fig. 3 Heat Control Diagram WATER FLOW AUTOMATIC OPERATION
ملخص المحتوى في الصفحة رقم 9
BREWING COFFEE PREPARATION CAUTION: Burn Hazard Place one (1) genuine Bloomfield paper filter in the brew chamber. Add a pre-measured amount of fresh coffee grounds. Exposed surfaces of the Gently shake the brew chamber to level the bed of grounds. Slide brewer and brew chamber the brew chamber into place under the brew head. may be HOT to the touch, and can cause serious burns. CAUTION: Burn Hazard To avoid splashing or over- f
ملخص المحتوى في الصفحة رقم 10
CLEANING INSTRUCTIONS CAUTION: PROCEDURE: Clean Coffee Brewer Burn Hazard PRECAUTIONS: Disconnect brewer from electric power. Brewing and serving Allow brewer to cool. temperatures of coffee are extremely hot. FREQUENCY: Daily Hot coffee will cause TOOLS: Mild Detergent, Clean Soft Cloth or Sponge serious skin burns. Bristle Brush. CAUTION: 1. Disconnect brewer from electri
ملخص المحتوى في الصفحة رقم 11
CLEANING INSTRUCTIONS (continued) CAUTION: PROCEDURE: Clean and Sanitize Basin Pan Electric Shock Hazard PRECAUTIONS: Disconnect brewer from electric power. Allow brewer to cool. Removing the top panel will expose uninsulated circuits. FREQUENCY: Monthly Unplug the brewer before removing the top panel. TOOLS: #2 Phillips Head Screwdriver This procedure to be performed Mild D
ملخص المحتوى في الصفحة رقم 12
TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won’t heat Brewer unplugged or circuit Check power supply cord breaker tripped Check / reset circuit breaker Thermostat set too low Set for desired temperature Hi-Limit thermostat tripped Allow to cool Reset hi-limit (8786, 8788) Damaged internal component or Examine wiring & connectors, wiring thermostat and heating element Repair/replace as needed Coffee level low Water bottle
ملخص المحتوى في الصفحة رقم 13
SERVICING INSTRUCTIONS ACCESS PANELS CAUTION Electric Shock Top panel is held by four screws at the corners. Hazard Front panel is held by two screws at the bottom and a retaining lip at the top. Opening access panels on this brew may expose uninsulated electrical components. Disconnect brewer from electrical power before removing any panel Fig. 8 Access Panels NOTE: TEMPERATURE ADJUSTMENT
ملخص المحتوى في الصفحة رقم 14
SERVICING INSTRUCTIONS (continued) IMPORTANT: Adjust timer with TIMER ADJUSTMENT a full water bottle installed in the The amount of water dispensed automatically during a brew cycle bottle ring. is controlled by the timer. Place empty airpot under brew chamber. Press BREW button. Brewer should dispense one airpot of water. To adjust amount: Remove brew chamber and button plug. Adjust knob on timer; clockwise increases time. Run several cycles to check amount of
ملخص المحتوى في الصفحة رقم 15
SERVICING INSTRUCTIONS (continued) REPLACE HEATING ELEMENT IMPORTANT: When replacing heating element, also replace Remove tank lid assembly per above. seal gaskets. Remove two hex nuts holding element to cover. Pull element from mounting holes. Reassemble in reverse order. REPLACE SOLENOID Symptom: brewer will not flow water; or, brewer drips continuously from brew head.) Unplug power cord or turn circuit breaker OFF. Turn OFF and disconnect water sup
ملخص المحتوى في الصفحة رقم 16
SERVICING INSTRUCTIONS (continued) CAUTION - PROCEDURE: Delime the Water Tank CHEMICAL BURN PRECAUTIONS: Disconnect brewer from electric power. HAZARD Allow brewer to cool. Deliming chemicals are caustic. Wear appropriate protective FREQUENCY: As required (Brewer slow to heat) gloves and goggles during this procedure. TOOLS: Deliming Solution Never siphon deliming Protective Gloves,
ملخص المحتوى في الصفحة رقم 17
SERVICING INSTRUCTIONS (continued) 7. Set the tank back into the brewer. Reassemble the tank lid to NOTE: Normally, silicone the water tank. Make sure the gasket is properly in place, hoses do not need to be then reinstall the hold-down strap. delimed. Should deliming hoses become necessary, 8. Reinstall wiring to heating element and thermostat. Reinstall Bloomfield recommends the hi-limit thermostat . Verify that all internal components replacin
ملخص المحتوى في الصفحة رقم 18
EXPLODED VIEW & PARTS LIST 8382 PLUMBING COMPONENTS ITEM PART# DESCRIPTION QTY 8 83538 TUBE, FAUCET SUPPLY 10” SILICONE 1 13 8043-5 STRAP, TANK LID HOLD DOWN 1 25 8043-13 ELBOW, BREW NOZZLE SILICONE 1 29 8783-1 FAUCET 1 30 8
ملخص المحتوى في الصفحة رقم 19
EXPLODED VIEW & PARTS LIST (continued) ITEM PART# DESCRIPTION QTY 31 8707-55 SWITCH, BREW MOMENTARY 120V 1 32 8718-31 INDICATOR LIGHT, GREEN 120V 1 35 8812-61 TIMER, 8 MIN 1 36 6407-15 POWER CORD, NEMA 5-15P 1 36t 8552-18 TERMINAL BLOCK, 4P 1 37
ملخص المحتوى في الصفحة رقم 20
EXPLODED VIEW & PARTS LIST (continued) ITEM PART# DESCRIPTION QTY 33 8543-42 GASKET, SPRAY DISK 1 34 84132 SPRAY DISK 1 34a 8543-45 BREW HEAD (must be drilled & riveted to install 1 70 8706-75 BUTTON PLUG, 2” DI