ملخص المحتوى في الصفحة رقم 1
INSTALLATION &
OPERATION MANUAL
V SERIES FOOD HOLDING AND
TRANSPORTATION CABINETS
AND BANQUET CARTS
MODELS
VHP3 ML-126343 VBS7 ML-138032
VHP7 ML-126344 VBS15 ML-138033
VHP8 ML-126345
VHDP5 ML-138035
VHP15 ML-126346
VDW3 ML-138036
VHP20 ML-126347 VB90 ML-126548
VBP5I ML-138030 VB96 ML-126550
VBP7I ML-126358 VB150 ML-126552
VBP13I ML-126359
VB200 ML-138034
VBP15I ML-126360
VBP77I ML-126361
For additional information on Vulcan-Hart or to locate an authorized parts
and service provider in your area,
ملخص المحتوى في الصفحة رقم 2
V SERIES IMPORTANT FOR YOUR SAFETY THIS MANUAL HAS BEEN PREPARED FOR PERSONNEL QUALIFIED TO INSTALL ELECTRICAL EQUIPMENT, WHO SHOULD PERFORM THE INITIAL FIELD START-UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL. FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE. WARNING IMPROPER INSTALLATION, ADJUSTMENT, ALTER- ATION, SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE, INJU
ملخص المحتوى في الصفحة رقم 3
200 80 60 190 180 170 V SERIES INSTALLATION, OPERATION AND CARE V SERIES FOOD HOLDING AND TRANSPORTATION CABINETS AND BANQUET CARTS SAVE THESE INSTRUCTIONS FOR Model VBP77I cabinets have individual FUTURE USE controls (Fig. 1) for each of the two compartments. The operator is able to hold Vulcan-Hart Holding and Transport Cabinets two different products at two different and Banquet Carts are produced with quality temperatures in separate sections of the same workmanship and material. Proper cabi
ملخص المحتوى في الصفحة رقم 4
200 80 60 190 180 170 70 5060 80 90 40 20 ® 10 15 00 20 0 °C °F 5 6 3 4 7 8 1 2 9 10 NSF POWER/HEAT OFF V SERIES INSTALLATION Before installing, verify the electrical service 4. On food holding and transport cabinets, agrees with the specifications on the rating remove cardboard element cover plate located on the lower rear of the cart. If protector from cabinet bottom. the electrical service does not agree with the Remove adjustable tray slides from box. rating plate, do not proceed with instal
ملخص المحتوى في الصفحة رقم 5
V SERIES INSTALLATION CODES AND ELECTRICAL CONNECTIONS STANDARDS Electrical and grounding The APPLIANCE must be installed in connections must comply with the accordance with: applicable portions ofthe National In the United States of America: Electrical code and/or other local electrical codes. 1. State and local codes. The cord and plug supplied, is a suitable 2. National Electrical Code, ANSI/NFPA-70 durable cord with molded plug and is provided (latest edition). Copies may be obtained with a
ملخص المحتوى في الصفحة رقم 6
V SERIES Electrical Connection Electrical and grounding Disconnect connections must comply with the electrical power to the applicable portions of the National machine and follow Lockout/ Electrical Code and/or other Local Tagout procedures before Electrical Codes. cleaning. MODEL VOLTAGE AMP PHASE HZ NEMA PLUG VBP5I, VBP7I, VBP13I, 110/120 10 1 60 5-15 VBP15I, VBS7, VBS15, 208/240 5.4 6-15 VHDP5, VDW3 VBP77I 110/120 20 1 60 5-20 208/240 10.9 6-20 VHP3, VHP7, VHP8 110/120 5 1 60 5-15 208/240
ملخص المحتوى في الصفحة رقم 7
200 80 60 190 180 170 V SERIES OPERATION The cabinet and its parts BEFORE FIRST USE are hot, be very careful when operating, Disconnect cleaning or servicing the cabinet. electrical power to the machine and follow Lockout/ Tagout procedures before CONTROLS cleaning. POWER FULL RANGE INDICATOR THERMOSTAT LIGHT 5 6 4 7 3 8 2 70 80 60 9 50 90 1 40 10 100 20 NSF® 105 0 POWER/HEAT °C 20 °F OFF HEAT THERMOMETER INDICATOR LIGHT Fig. 4 HOLDING COMPARTMENTS POWER INDICATOR LIGHT Lit when power is supplie
ملخص المحتوى في الصفحة رقم 8
200 80 60 190 180 170 V SERIES OPERATING APPLIANCE 1. Connect electric power supply. Power indicator light is lit. 70 80 60 90 50 40 100 20 NSF ® 105 0 PO °C 20 °F Fig. 8 4. Once desired temperature is reached, heating elements will cycle on and off. Heat light(s) will cycle on and off with the heating elements. 5. Temperature in heated appliance will fluctuate as the heating elements cycle Fig. 6 on and off. 2. Turn thermostat knob to desired setting. 6. Monitor the food product to ensure p
ملخص المحتوى في الصفحة رقم 9
V SERIES Shutdown CLEANING Turn full range thermostat counterclockwise Disconnect to OFF. electrical power to the machine and follow Lockout/ Tagout procedures before cleaning. 5 6 4 7 3 8 2 9 Clean appliance interior with mild soap and 1 10 water whenever a food spill occurs. Never use harsh chemicals or abrasive pads to clean EAT appliance. OFF Daily 1. Allow appliance to cool before cleaning. Fig. 9 2. Remove tray slides or plate racks and clean in a sink as you would any utensil. Unplug elec
ملخص المحتوى في الصفحة رقم 10
V SERIES TROUBLESHOOTING SYMPTOMS POSSIBLE CAUSES REMEDY Temperature incorrect No main power source Check the power source or circuit breaker. Power switch in off position Press power switch to the on position. Door open Close door. Door leaks Damaged door gasket Check door gasket for damage. If adjustment is needed, contact your Authorized Vulcan-Hart Servicer. Compartment does Defective heating coil Contact your authorized service provider. not heat properly Defective thermostat or Contact you
ملخص المحتوى في الصفحة رقم 11
V SERIES WIRING DIAGRAMS POWER POWER THERMOSTAT A A R BLACK POWER CONNECTION 120V, 1PH, 60 Hz 208/240V, 1PH, 60 Hz RED BLACK WHITE WHITE GREEN HEATING HEATING ELEMENT ELEMENT VB48, VB72, VB90, VB96, VB150, VBP5I, VBP7I, VBP13I, VBP15I, VHP15, VHP20 Wiring Diagram — 11 —
ملخص المحتوى في الصفحة رقم 12
V SERIES POWER POWER BLACK POWER BLACK CONNECTION R A WHITE 120V, 1PH, 60 Hz 208/240V, 1PH, 60 Hz GREEN THERMOSTAT HEATING ELEMENT POWER POWER BLACK R A THERMOSTAT HEATING ELEMENT VBP77I Wiring Diagram — 12 —
ملخص المحتوى في الصفحة رقم 13
V SERIES POWER THERMOSTAT A A RED BLACK POWER CONNECTION WHITE WHITE 120V, 1PH, 60 Hz GREEN 208/240V, 1PH, 60 Hz HEATING ELEMENT VHP3, VHP7, VHP8 Wiring Diagram — 13 —
ملخص المحتوى في الصفحة رقم 14
V SERIES VULCAN REPLACEMENT PARTS LIST BOLT, RETAINING RACK (PACK OF 4) WP-305 851800-26 CAP, CHROME INSPECTION WP-174 851800-23 CLIP, ELEMENT WP-182 851800-14 CORD, POWER 12/3 120V. 15 AMP WP-015-1 851800-99 CORD, POWER 12/3 120V. 20 AMP WP-247 851800-148 CORD, POWER 12/3 208/240V. 15 AMP WP-015-2 851800-213 CORD, POWER 16/3 120V. WP-052 851800-6 ELEMENT, 120V – 1000W WP-105-1 851800-151 ELEMENT, 120V – 600W (1220/1826) WP-104-1 851800-11 ELEMENT, 208/240V – 600W (1220/1826) WP-104-2 851800-13
ملخص المحتوى في الصفحة رقم 15
V SERIES NOTES (9-07) PRINTED IN U.S.A. — 15 —
ملخص المحتوى في الصفحة رقم 16
V SERIES SERVICE AND PARTS INFORMATION To obtain service and parts information concerning this model, contact the Vulcan-Hart Service Agency in your area (refer to our website, www.vulcanhart.com for a complete listing of Authorized Service and Parts depots). When calling for service, the following information must be available: model number, serial number, manufacture date (MD) and voltage. — 16 —