ملخص المحتوى في الصفحة رقم 1
ODSHR Series
Outdoor Woodburning Fireplace
Homeowner's Installation
and Operating Manual
Model:
ODSHR42
1384
SHR cover
5/27/99 djt
Underwriter's Laboratories
Report No. MH20546
DO NOT DISCARD THIS MANUAL: Retain for future use.
20002264 10/06 Rev. 17
ملخص المحتوى في الصفحة رقم 2
ODSHR Outdoor Woodburning Fireplace Table of Contents PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING FIREPLACE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions may result in a possible fire hazard and will void the warranty. Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 Specifications and Framing Dimensions . . . . . . . . . . . . . . . . . . .
ملخص المحتوى في الصفحة رقم 3
ODSHR Outdoor Woodburning Fireplace Safety Information NOTE: This unit is intended for outdoor use in the United States using CF11 or SK chimney systems. The unit may be installed indoors, in the U.S. only, using CF11 chimney system only. This unit is intended for outdoor use in Canada using the SK chimney system only. Do not obstruct or modify air inlets/outlets in any Description manner. Do not install combustible materials on any of the The ODSHR Series (Super Hearth) fireplace is a clea
ملخص المحتوى في الصفحة رقم 4
ODSHR Outdoor Woodburning Fireplace ODSHR42 Series Woodburning Fireplace Minimum ��" Rough (889 mm) ���" Opening Depth 13���" Dia. 62 ���" (1578 mm) ����� " (340 mm) 264 mm) ����� " (280 mm) 11" Dia. ���" ���" (279 mm) Minimum Rough Opening Minimum Width 53���" (1365 mm) Rough Opening Height ���" 12���" (318 mm) 48���" (1226 mm) 15 ���" (397 mm) 44" Outside �� " Gas Line 42" (1118 mm) Air (610 mm) Access (1067 mm) 13���" �����" (349 mm) (189 mm) 14���" 7���" 52 ���" Gas Line Access (368
ملخص المحتوى في الصفحة رقم 5
ODSHR Outdoor Woodburning Fireplace Chase Installation Exterior Chase Installation Insulation methods shown are optional for cold climate, not a requirement for unit operation or exterior installation . Termination Cap Interior Chase Storm Collar Termination Cap Installation Pan Flashing Storm Collar Pan Flashing Batt Insulation (cut out around Exterior firestop) Siding Draftstop Exterior Siding Firestop Ceiling Level Interior sides of chase Ledge should be Bracket weather proof Surrou
ملخص المحتوى في الصفحة رقم 6
ODSHR Outdoor Woodburning Fireplace Chimney Requirements - Offset Installations OFFSET CHIMNEY FLUE EXIT RISE CHIMNEY IWF282 SECTION 30˚ Elbow Offsets 30˚ ELBOW IWF282 RETURN ELBOW MBUF B 1' Offset 1 ¹⁄₂' 3' 4' Rise G A 5/26/96 0 0 0 0 0 3" 11" G 30˚ 1 0 0 0 0 8 ¹⁄₄" 20" OFFSET 0 1 0 0 0 11 ¹⁄₄" 25 ¹⁄₄" D ELBOW E 2 0 0 0 0 13 ¹⁄₂" 29 ¹⁄₄" RISE 6 FT. 1 1 0 0 0 16 ¹⁄₂" 34 ¹⁄₄" 11CS 30˚ C 0 0 1 0 0 20 ¹⁄₄" 40 ³⁄₄" SUPPORT RETURN H ELBOW 2 1 0 0 0
ملخص المحتوى في الصفحة رقم 7
ODSHR Outdoor Woodburning Fireplace Planning Information Preplanning an installation is very important to ensure The Ten Foot Rule safety and to save time and money. An installer must predetermine where a fireplace will be set and how the Major U.S. building codes specify a minimum chimney chimney system will be run. height above the roof top. The “Ten Foot Rule” is a fire safety rule and not a draft rule. To ensure proper draft, Mounting the Fireplace it is recommended that you always mee
ملخص المحتوى في الصفحة رقم 8
ODSHR Outdoor Woodburning Fireplace Chimney Supports Installation The chimney system is supported by the fireplace for vertical chimney heights less than 30' (9 m) above the Insulating Fireplace Enclosure hearth. Chimney supports are required if the vertical for Cold Climates height exceeds 30' (9 m) with 11CF chimneys. Locate chimney supports at ceiling holes or other structural If you live in a cold climate, it is not required but framing at 30 foot heights. Spacing between chimney hig
ملخص المحتوى في الصفحة رقم 9
ODSHR Outdoor Woodburning Fireplace Locate center point of the chimney on ceiling as though Framing a straight up chimney arrangement is to be used. Mea- Framing can be constructed before or after the fireplace sure your offset dimension from straight up chimney is set in place, however, most installers build the frame center point on ceiling. before setting the fireplace. Ceiling Chimney Hole/ Possible Obstructions Frame fireplace with 2 x 4 lumber or heavier materials. The size of the ho
ملخص المحتوى في الصفحة رقم 10
ODSHR Outdoor Woodburning Fireplace Cutting the Hole 17 ¹⁄₂" Existing (445 mm) Cover fireplace collar opening and cut proper sized 17 ¹⁄₂" Ceiling (445 mm) Joists chimney hole in chimney. Chimney Framing the Ceiling Hole Hole Frame the ceiling chimney hole as shown in Figure 13. It is good practice to use framing lumber that is the same size as the ceiling joists; this is a requirement at attic level. The following table gives firestop spacer model num- bers: New Framing Members Chimney Ho
ملخص المحتوى في الصفحة رقم 11
ODSHR Outdoor Woodburning Fireplace Positioning, Safety Strips, Securing the Fireplace Slide fireplace into position. Metal Safety Strips Lift the fireplace front slightly and slide the metal safety (1, 2 or 3 pieces) strips under front bottom edge about 1 ¹⁄₂" (38 mm), allowing the remainder to extend in front of firebox. Overlap strips at least 1/2" (13 mm) to provide a posi- "Z" Safety Fire- tive joint. (Flat safety strips are packed with fireplace.) Strip place (Fig. 12) (not supplied)
ملخص المحتوى في الصفحة رقم 12
ODSHR Outdoor Woodburning Fireplace Installing the Chimney System Inner Pipe Section Start by attaching the first chimney section to the collar on top of the fireplace. Pipe Rim Hem Install the pipe as pictured in Figure 17. When you get a good lock, you will hear the pipe clearly snap Lance together. Once sections are snap-locked in place, it is Pipe extremely difficult to get them apart. Make sure the Rim pipe is firmly snapped and locked together as each pipe section is mounted. Whe
ملخص المحتوى في الصفحة رقم 13
ODSHR Outdoor Woodburning Fireplace Firestop spacers are not available for, nor are they WARNING: DO NOT PACK REQUIRED AIR SPACES required on, vertical walls. WITH INSULATION OR OTHER MATERIALS. The CFM Corporation chimney components have been Mark an outline of the roof hole around the centerpoint tested and approved with the area where the outer of the nail. NOTE: Hole dimensions given in the chim- pipe slides through the firestop spacer sealed with a ney top installation instructions are h
ملخص المحتوى في الصفحة رقم 14
ODSHR Outdoor Woodburning Fireplace Air Space Clearances Finished Wall Stud Combustible framing material MUST NOT pen- etrate AIR SPACE (shaded areas) Noncombustible Decorative Fac- ing 2 x 4 Header 2" Must be Sealed Ledge Bracket with Noncombustible Standoff Material ³⁄₄" Air Space to Sides Side View Side View Front View Surround FP1166 Firestop Fig. 21 Fireplace surround flush with finished wall. Stud Wall ³⁄₄" Air Space Finished Wall Shield to Back FP1166 surround flush 2 x 4 Finished
ملخص المحتوى في الصفحة رقم 15
ODSHR Outdoor Woodburning Fireplace Mantel Clearance - No Noncombustible Facing Material Combustible Mantel 12" 12" and Trim Combustible Mantel (305mm) (305mm) Finished Wall Finished Wall and Trim Max. Max. Header Header 1 ¹⁄₂" 1 ¹⁄₂" Standoff Standoff 12" 12" Noncombustible (305mm) Noncombustible (305mm) Material Material min. min. Surround Surround Face Face 6" * (159mm) Noncombustible Facing Min. Material Fireplace Opening Fireplace Opening * Minimum width from top of sur- Must be sea
ملخص المحتوى في الصفحة رقم 16
ODSHR Outdoor Woodburning Fireplace 40" Side Wall Protection Min. Adjacent combustible side walls that are within dimen- sions shown in Figure 25 of fireplace opening must be protected with CFM Corporation Wall Shield Model SP40 or a specifically built wall shield described in Figure 26. 40" Min. The special wall shield design described in Figure 26 is an alternate method of adding protection to side walls and can be used in place of the SP40 with the same wall clearances specified for the S
ملخص المحتوى في الصفحة رقم 17
ODSHR Outdoor Woodburning Fireplace Alternate noncombustible materials may be used pro- Seal Cracks Between Fireplace and Hearth Noncombustible viding the (total) thermal resistance (Rt value) of the al- Extension with Non- Decorative Covering ternate material employed is greater than or equal to R combustible Material May be Installed or = 1.09. Thermal resistance (R) or thermal conductivity .018" Minimum (K), may be obtained from manufacturer of the material. Sheet Metal Factors a
ملخص المحتوى في الصفحة رقم 18
ODSHR Outdoor Woodburning Fireplace BTU input of a gas appliance installed in fireplace Wall Covering 2 x 4 Header should be rated less than 100,000 BTU/Hr. - Do Not Notch at Noncombustible Ledge Brackets Decorative Facing Gas pipe installation is intended for connection to a decorative gas appliance only when (1.) incorporating Seal All Cracks Between Fireplace an automatic shutoff device and (2.) complying with the Surround and Wall Standard for Decorative Gas Appliances for Installa-
ملخص المحتوى في الصفحة رقم 19
ODSHR Outdoor Woodburning Fireplace 1 2 3 9a,b 4 8 6 10 7 5 11 13 12 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. ODSHR Outdoor Woodburning Fireplace Ref. Description Part Number 2264pts 1. Damper Blade 3990185 odshr 2. Damper Handle 20001418 3. Screen Rail 20002262 replacement parts 4. Screen Rod 20002222 1/5/00 djt 5. Screen (two per fireplace) 20002223 6. Screen Pull (t
ملخص المحتوى في الصفحة رقم 20
ODSHR Outdoor Woodburning Fireplace Accessories The following accessories for this appliance are available from your local CFM Corporation products distributor. Should you need additional information beyond what your distributor can furnish, contact: CFM Corporation, 2695 Meadowvale Blvd., Mississauga, Ontario, Canada L5N 8A3, Attn: Technical Services. CAUTION: This fireplace and chimney assembly is a highly engineered system, and, as such, must be oper- ated only with CFM Corporation approved