BREW CENTER, COFFEE BREWING EQUIPMENT
TWIN: BC2, BC302 SINGLE: BC1, BC301, BC120, BC240
BC-2E BC-1E
BREWERS SHOWN WITH OPTIONAL STAINLESS STEEL FUNNEL
MANUAL
* Specifications * Start up procedure * Adjustments * Parts Identification
* Installation * Operating Instructions * Care Maintenance * Wiring Diagram
Cecilware sells value... Worldwide
43 -05 20th Avenue, Long Island City, NY 11105 TEL: 7
ملخص المحتوى في الصفحة رقم 2
SPECIFICATIONS ELECTRICAL SPECIFICATIONS MODEL NO. BC1 BC301 BC120 BC240 BC2 BC302 Volts 120/240 120/240 120 240 120/240 120/240 Watts 4100 4100 1800 3120 6200 6280 Amps 18 18 15 13 27 27 Wall Outlet (Receptacle) 6-20R 6-20R 5-15R 6-15R 6-30R 6-30R Power Cord CE202 – 30A optional All Brew Centers are single phase with 3 wires plus a ground with cord and plug, except Eport 220V, 1 PH, (UROPEAN). MECHANICAL SPECIFICATIONS MODEL NO. BC1 BC301 BC120 BC240 BC2 BC302 Tank Capacity (US g
ملخص المحتوى في الصفحة رقم 3
INSTALLATION AND OPERATING INSTRUCTIONS Warranty is void if the Brewer is connected to any Voltage other than the Voltage specified on the data label of the Brewer. UNPACKING AND INSPECTION Carefully unpack the Brewer by cutting the straps and lifting the carton off the Brewer. ASSEMBLY AND SET-UP The Brewer is shipped complete with: DESCRIPTION BC1, 301, 120, 240 BC2, 302 Adjustable legs 4 4 Carriers complete with Faucets and Covers 1 2 Funnels with sample Filter pack 1
ملخص المحتوى في الصفحة رقم 4
INITIAL PRIMING – Filling of Tank The BC Brewers are shipped with the Thermostat in the OFF position. Do not turn Thermostat to the ON position until the Brewer has been fully primed. a. Turn water supply on and check for leaks at the water inlet connections. Tighten compression fitting if necessary. b. Turn on power to the Brewer. The Brewer will automatically start filling. After 6 minutes the filling cycle will stop and the thermostat should be turned clockwise to the full ON
ملخص المحتوى في الصفحة رقم 5
ADJUSTMENTS 1. BY-PASS FLOW VALVE ADJUSTMENTS Depending on the model number, the BC Brewers have been factory set to brew 12, 24 and/or 36 cups of coffee, with the BY-PASS adjusted for a 20% BY-PASS flow of brewing water for the 36 cup, brew output only. Since water hardness, the brand of coffee, and the length of brew time are important factors in final drink taste, it may be necessary to adjust the percentage of BY-PASS. In general, the more ground coffee used for each brew, the h
ملخص المحتوى في الصفحة رقم 6
2. TIMER ADJUSTMENT PROCEDURE Remove the top cover to access the brew timer(s). To INCREASE output: turn timer knob a small increment CLOCKWISE. To DECREASE output: turn timer knob a small increment COUNTER-CLOCKWISE. Check output level in carrier. REMOVE JUMPER FOR 240V BCI, BC2 BC120, BC240 BC301, BC302 Single Timer (L264A) Dual Timer (58026) 120 Triple Ti
ملخص المحتوى في الصفحة رقم 7
SPECIAL COMPONENTS TEST 1) CHECK DISPENSE VALVES FOR LIME BUILD-UP (Located inside top cabin) Drain the water tank to just below the level of the Dispense Valves. Remove the Valves and clean. You can take these valves apart by hand as shown. Replace the assembly as needed. Replace the valve into the tank and refill tank. 2) WATER INLET VALVE (SOLENOID) TEST (Located inside bottom cabin) Turn power off. If the water level rises inside the tank, and shoots out
ملخص المحتوى في الصفحة رقم 8
TROUBLESHOOTING GUIDE WARNING: To reduce the risk of electrical shock unplug the dispenser power cord before repairing or replacing any internal components of the unit.. Before any attempt to replace a component be sure to check all electrical connections for proper contact PROBLEM PROBABLE CAUSE REMEDY 1. a) Loose wire connection. a) Check wire connections to Power Switch. No power to the b) Blown fuse. b) Check fuse. machine. c) Tripped Breaker c) Re-set Breaker 2. a) Dispense Swi
ملخص المحتوى في الصفحة رقم 9
CLEANING AND SANITIZING SANITIZING: All food dispensing units should be sanitized periodically. All parts to be sanitized must be cleaned first. To prepare a sanitizing solution: ADD 2 TSP. OF LIQUID CLOROX BLEACH (5.25% CONCENTRATION) TO 1 GALLON OF WATER AT ROOM TEMPERATURE (70°- 90°F). Note: Always start with a unopened bottle of Clorox Bleach since the solution from an opened bottle has a short life span. • Soak all parts for a minimum of 3 min. in the sanitizing solution. • L
ملخص المحتوى في الصفحة رقم 10
BC302 FRONT OPEN VIEW 1 PARTS IDENTIFICATION [* RECOMMENDED SPARE PARTS] 2 SINGLE UNITS TWIN UNITS 3 BC1, BC301, BC2, BC302 BC120, BC240 4 ITEM P/N QTY P/N QTY DESCRIPTION 1 SF26A 1 SB49A 1 CABINET TOP COVER 5 2 --- -- ---- -- SWITCH PANEL LABELS: N829A 1 --- -- BC120 & BC240 6 N892A 1 N815A 1 BC1 / BC2 N822A 1 N823A 1 BC301 / BC302 7 5* L155A 2 L155A 2 BC2 ON-OFF SWITCH L155A 1 L155A 1 BC120 ON-OFF SWITCH 8 L155A 1 L155A 1 BC240 ON-OFF S
ملخص المحتوى في الصفحة رقم 11
TOP CABIN OPEN VIEW 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 1 9 1 TOP CABIN - PARTS IDENTIFICATION [* RECOMMENDED SPARE PARTS] ITEM SPARE SINGLE UNITS TWIN UNITS DESCRIPTION PARTS P/N QTY P/N QTY 1 * L656A 1 L656A 1 HI-LIMIT 2 * L499A 1 L499A 1 FLOAT SENSOR WITH M532A 1 M523A 1 RUBBER GASKET 3 * G367A 1 G367A 2 HEATER (1.7 KW 120V) OR G369A G369A HEATER (3.0 KW 230V) OR G286A G286A HEATER (4.0 KW 230
ملخص المحتوى في الصفحة رقم 12
BOTTOM CABIN OPEN VIEW 1 5 4 3 2 BOTTOM CABIN - PARTS IDENTIFICATION [* RECOMMENDED SPARE PARTS] SPARE BC2-IT BC301-IT PARTS BC302-IT ITEM P/N QTYP/N QT DESCRIPTION Y 1 * L069A 1 L069A 1 POWER SWITCH 2 B083A 1 B083A 1 TERMINAL BLOCK 3 * CD257 1 CD257 1 WATER INLET VALVE 4 C396A 1 C396A 1 FUSE HOLDER * C395A 1 C395A 1 FUSE 5 * CE202 1 CE202 1 POWER CORD 120/240V or CG99A CG99A POWER CORD 240V 12
ملخص المحتوى في الصفحة رقم 13
CARRIER ASS’Y 1 2 3 4 5 6 7 14 CARRIER ASS’Y 97208 [* RECOMMENDED SPARE PARTS] 13 Item Description Part # 1 * Handle, black 3” 02015 2 * Hold Down Bracket U833A 2 * Thumb Screw M299A 12 3 * Carrier Cover S.S. U811A * Gasket, Cover Carrier M294A 8 4 Label NG47A 11 5 Screw P808A 6 * Faucet Guard U812A 9 7 * Faucet & Shank Ass’y 8” 99461 8 * Faucet Washer 7227 10 9 * Fa
ملخص المحتوى في الصفحة رقم 14
BC-1E 120/240 3 WIRES + GROUND 3100 WATTS 14A 1 PH 60Hz BREW CIRCUIT REFILL CIRCUIT PROBE N L BREW VALVE L1 R B W LOAD FAUCET & SHANK ASS’Y 99461 BLK HI LIMIT RED BLK GND L1 FUSE 6 AMP. N RED L2 BLACK WHITE D C.G. C.G. - D 14
ملخص المحتوى في الصفحة رقم 15
BC120E 2 WIRES+GRD 1800W 15A 1PH BC240E 2 WIRES+GRD 3120W 13A 1PH BREW INDICATOR LIGHT PROBE N L1 LOAD L2 S L1 SW2 SW3 I2 I1 FLOAT SWITCH BLK WARMER HI LIMIT BC-120E DUAL BREWTIME BC-240E DUAL BREWTIME BLK GND L1 FUSE 6 AMP. N RED BLACK WHITE A C.G. C.G. - A 15 12 CUP 24 CUP
ملخص المحتوى في الصفحة رقم 16
BC-301E 120/240 3 WIRES+GND 4140W 18A 1PH 60HZ REFILL CIRCUIT BREW CIRCUIT INLET VALVE PROBE 12 24 36 N L1 LOAD 11 89 10 BLK HI LIMIT RED BLK BC-301E TRIPLE BREW TIME GND BLK L1 FUSE 6 AMP. N RED L2 BLACK WHITE C C.G. C.G. - C 16
ملخص المحتوى في الصفحة رقم 17
BC-2E 120/240 3 WIRE+GRD 6230W 26A 1PH 60HZ PROBE PROBE N L1 LOAD L L W RB W R B BC-2E SINGLE BREW TIME BLK HI LIMIT RED BLK RED GND BLACK L1 WHITE N L2 C.G. C C.G. - C 17
ملخص المحتوى في الصفحة رقم 18
PROBE N L1 11 8 9 10 1181 90 LOAD BLK HI LIMIT RED BLACK RED BLK WHITE GND L1 N L2 D C.G. C.G. - D 18 24 CUP 12 CUP 12 CUP 36 CUP 24 CUP 36 CUP 24 CUP 12 CUP 12 CUP 36 CUP 24 CUP 36 CUP