ملخص المحتوى في الصفحة رقم 18
TROUBLESHOOTING (cont.) BREWING CIRCUIT (cont.) PROBLEM PROBABLE CAUSE REMEDY Brew cycle will not start (cont.) 8. Control board or dispense valve If the switch panel is operating prop- erly, proceed as follows. Attach a voltmeter to the terminals of the dispense solenoid. Connect the brewer to the power source. Turn on the brewer and press the BREW switch. Voltage should be present at the solenoid terminals. If voltage is not present, refer to the wiring diagrams and check the wiring har- ness
ملخص المحتوى في الصفحة رقم 19
TROUBLESHOOTING (cont.) BREWING CIRCUIT (cont.) PROBLEM PROBABLE CAUSE REMEDY Dripping from sprayhead 1. Lime build up Inspect the tank assembly for ex- cessive lime deposits. Delime as required. 2. Dispense valve Remove the dispense valve and clear any obstructions. Rebuild or re- place the valve if necessary. (See page 24) Weak beverage 1. Sprayhead A six-hole stainless steel sprayhead must be used for proper extraction. 2. Water temperature Place an empty brew funnel on an empty decanter bene
ملخص المحتوى في الصفحة رقم 20
TROUBLESHOOTING (cont.) BREWING CIRCUIT (cont.) PROBLEM PROBABLE CAUSE REMEDY Dry coffee grounds remain in the 1. Sprayhead Make sure sprayhead is present and funnel holes are clear and unobstructed. There should be six separate streams of water coming out of the sprayhead. ® 2. Funnel loading The BUNN paper filter must be centered in the funnel and the bed of grounds leveled by shaking gen- tly. Low beverage serving temperature 1. Warmer Disconnect the brewer from the power source. Remove the w
ملخص المحتوى في الصفحة رقم 1
CDBC-MV, CDBCF-MV
CDBC-MV, CDBCF APS-MV
CDBC-DV, CDBCF-DV
CDBC APS-DV CDBCF APS-DV
(DV Models prior to
Serial #CDBC024477)
DISCONTINUED VERSION
The information in this manual
is no longer current.
OPERATING & SERVICE MANUAL
BUNN-O-MATIC CORPORATION
POST OFFICE BOX 3227
SPRINGFIELD, ILLINOIS 62708-3227
PHONE: (217) 529-6601 FAX: (217) 529-6644
29707.0000H 10/03 ©1999 Bunn-O-Matic Corporation www.bunnomatic.com
BUNN
CAUTION :
ملخص المحتوى في الصفحة رقم 2
INTRODUCTION This equipment will brew a half-gallon batch of coffee into an awaiting dispenser. It can be easily configured for 120V 15 amp, 120V 20 amp (MV models only), 120/208V 20 amp or 120/240V 20 amp. The brewer may have a hot water faucet for allied beverage use. It is only for indoor use on a sturdy counter or shelf. BUNN-O-MATIC COMMERCIAL PRODUCT WARRANTY Bunn-O-Matic Corp. (“BUNN”) warrants equipment manufactured by it as follows: 1) All equipment other than as specified below: 2 year
ملخص المحتوى في الصفحة رقم 3
USER NOTICES Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should be kept in good condition. Replace any unreadable or damaged labels. Optional Field Wiring 120 V, 17.0 A, 2050 W 1PH, 2-Wire, 60HZ or 120/208-240 V, 13.6-15.3 A, 2640-3430 W 1PH, 3-Wire, 60HZ #29710.0002 (MV models only) TWO WARMER BREWERS Optional Field Wiring #00658.0000 120 V, 18.0 A, 2150 W 1PH, 2-Wire, 60HZ or 120/208-240 V, 14.4-16.2 A, 2740-3530 W 1PH,
ملخص المحتوى في الصفحة رقم 4
USER NOTICES (CONT.) Optional Field Wiring Optional Field Wiring 120/208-240 V, 15.6-17.5 A, 2980-3850 W 120 V, 15.0 A, 1800 W 1PH, 2-Wire, 60HZ 1PH, 3-Wire, 60HZ #29710.0005 (DV models only) #29710.0007 (DV models only) CDBCF-DV BREWERS NO WARMER BREWERS Optional Field Wiring Optional Field Wiring 120 V, 16.2 A, 1950 W 1PH, 2-Wire, 60HZ 120/208-240 V, 13.0-15.0 A, 2680-3550 W or 1PH, 3-Wire, 60HZ 120/208-240 V, 12.7-14.5 A, 2540-3330 W 1PH, 3-Wire, 60HZ #29710.0001 (MV model
ملخص المحتوى في الصفحة رقم 5
Models CDBC-DV, CDBC-APS DV & CDBCF LPTC-DV ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. Brewers with an attached cord set require 2-wire, grounded service rated 120 volts ac, 15 amp, single phase, 60 Hz. Requirements for brewers without an attached cord set are as follows: 1425W VERSION 3180W VERSION Requires 2-wire, Requires 3-wire, grounded service grounded service rated 120 volts ac, rated 120/240 volts 15 amp, sin
ملخص المحتوى في الصفحة رقم 6
Models CDBC-MV & CDBC-APS MV ELECTRICAL REQUIREMENTS CAUTION - The brewer must be disconnected from the power source until specified in Initial Set-Up. TANK HEATER TERMINAL BLOCK WIRING DIAGRAM (CDBC-MV MODELS) 2390W @ 120/208V or 1800W @ 120V 1425W @ 120V 3180W @ 120/240V 1800W 1800W 1800W 1425W 1425W 1425W B B W B B W B B W L L L L L L H H H K U K U K U T T T BLK WHI RED BLK WHI RED BLK RED WHI L2 RED L2 RED L2 RED 120V A.C. WHITE WHITE WHITE 208 or 240V A.C. NEUTRAL NEUTRAL NEUTRAL 120V A.C.
ملخص المحتوى في الصفحة رقم 7
PLUMBING REQUIREMENTS These brewers must be connected to a cold water system with operating pressure between 20 and 90 psi (138 1 and 620 kPa) from a ⁄2" or larger supply line. A shut-off valve should be installed in the line before the brewer. Install a regulator in the line when pressure is greater than 90 psi (620 kPa) to reduce it to 50 psi (345 kPa). The water 1 inlet fitting is ⁄4" flare. 1 3 NOTE - Bunn-O-Matic recommends ⁄4" copper tubing for installations of less than 25 feet and ⁄8"
ملخص المحتوى في الصفحة رقم 8
OPERATING CONTROLS ON/OFF SWITCH Pressing the "ON/OFF" switch (indicator glowing) supplies power to the brew station warmer, enables the brew circuit, and energizes the tank refill circuit. Pressing the switch again (indicator not glowing) stops tank refilling and brewing and de-energizes the brew station warmer. Stopping a brew cycle after it has been started will not stop the flow of water into the decanter until the funnel is empty. P1626 NOTE – Hot water will be available at the faucet in a
ملخص المحتوى في الصفحة رقم 9
ADJUSTMENTS & OPTIONAL SETTINGS HIDDEN SWITCH P1866 Setting Brew Temperature The brewer is factory set to brew at 200°F (95°C). To change this setting, press and hold the "HIDDEN" switch beneath the "®". The word "TEMP" above the "ON/OFF" switch will glow to correspond with the temporary function change of this switch. Repeatedly press and release the "ON/OFF" switch until one of the bank of temperature indicators shows the approximate desired temperature. When two indicators are glowing, the te
ملخص المحتوى في الصفحة رقم 10
ADJUSTMENTS & OPTIONAL SETTINGS (CONT.) 3. Press and hold the brew start button until you hear the brew solenoid click on-and-off three times (approximately 5 seconds). Release the button. 4. Allow the cycle to continue until the desired amount of water is dispensed and then turn "OFF" the brewer. The brewer is now set to dispense this amount of water for each subsequent brew cycle. To increase the amount of water for each brew cycle place an empty funnel in the funnel rails and an empty decante
ملخص المحتوى في الصفحة رقم 11
TROUBLESHOOTING A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic Technical Service Department. • Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel. • All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of terminals or the appl
ملخص المحتوى في الصفحة رقم 12
TROUBLESHOOTING (cont.) REFILL CIRCUIT PROBLEM PROBABLE CAUSE REMEDY Will not fill or refill 1. Power off to brewer Press warmer switches on control panel to determine if power is ON. 2. Water shut off Make sure water is ON. 3. Display flashing Brewer has shut down due to mal- function (See Diagnostic Chart in manual, Page 20, or under top lid of brewer). Make sure ON/OFF Switch is "ON" 4. ON/OFF Switch and indicator is lit. Remove the Level Probe and check 5. Lime build up on Probe for lime dep
ملخص المحتوى في الصفحة رقم 13
TROUBLESHOOTING (cont.) REFILL CIRCUIT (cont.) PROBLEM PROBABLE CAUSE REMEDY Fill or refill does not shut "OFF" (ON/ 1. Lime build up on probe Remove Level Probe and check for OFF Switch "ON") lime deposits on tip. Clean and rein- stall. 2. Water Level Probe Sensing Sys- Disconnect the brewer from the tem power source. Disconnect the J3 connector from the control board. Check for continuity from the nut on top of the level probe to pin 1 of the plug, continuity should be present. Pull the temper
ملخص المحتوى في الصفحة رقم 14
TROUBLESHOOTING (cont.) HEATING CIRCUIT PROBLEM PROBABLE CAUSE REMEDY Water does not heat to proper tem- 1. Display flashing Brewer has shut down due to mal- perature function (See Diagnostic Chart in manual, Page 20, or under top lid). IMPORTANT: Make sure no tem- perature tests are taken before the Remove temperature probe and 2. Water not touching temperature ready light is "ON". Tank tempera- grommet. Look into hole on tank probe ture must be stabilized before read- lid. Water must be within
ملخص المحتوى في الصفحة رقم 15
TROUBLESHOOTING (cont.) HEATING CIRCUIT (cont.) PROBLEM PROBABLE CAUSE REMEDY Water does not heat to proper tem- 6. Tank Heater Disconnect the brewer from the perature (cont.) power source. Check for continuity between the white terminal of the IMPORTANT: Make sure no tem- terminal block (or red terminal on perature tests are taken before the 208/240volt models) and the black ready light is "ON". Tank tempera- wire on the relay on the control ture must be stabilized before read- board (Toggle Sw
ملخص المحتوى في الصفحة رقم 16
TROUBLESHOOTING (cont.) HEATING CIRCUIT (cont.) PROBLEM PROBABLE CAUSE REMEDY Spitting or excessive steaming 1. Lime build up on temperature Inspect probe and tank assembly (cont.) probe, tank or tank heater for excessive lime deposits. Delime as required. 2. Temperature Probe Remove the probe from the grom- met and submerge in a water bath of approximately 70°F(21°C). Con- nect an ohmmeter to pins 3 and 4 of the J3 connector. At 60°F(16°C) the reading should be 15.3k ± 2k OHMS, at 70°F(21°C) th
ملخص المحتوى في الصفحة رقم 17
TROUBLESHOOTING (cont.) BREWING CIRCUIT PROBLEM PROBABLE CAUSE REMEDY Brew cycle will not start 1. Display flashing Brewer has shut down due to mal- function (See Diagnostic Chart in manual, Page 20, or under top lid of brewer). Water lines and valves to the brewer 2. No water must be open. Check for voltage across the termi- 3. No power or incorrect voltage to nals at the terminal block. the brewer The indicator lamp must be lit 4. ON/OFF switch not in the "ON" position Allow brewer to heat un