ملخص المحتوى في الصفحة رقم 1
687
OWNERS MANUAL
For
COFFEE BREWERS
MODELS:
9600 SINGLE CUP
INCLUDES:
Installation
Operation
Use & Care
Servicing Instructions
Model: 9600 Single Cup Brewer
PRINTED IN CHINA
p/n 77195 Rev. (-) ECN12792 M687 050207 cps
ملخص المحتوى في الصفحة رقم 2
WARRANTY STATEMENT All electrical equipment manufactured by BLOOMFIELD It also does not apply if the serial nameplate has been INDUSTRIES is warranted against defects in materials and removed or unauthorized service personnel perform service. workmanship for a period of one year from the date of original The prices charged by Bloomfield Industries for its products installation or eighteen (18) months from the date of shipment are based upon the limitations in this warranty. Seller
ملخص المحتوى في الصفحة رقم 3
TABLE OF CONTENTS WARRANTY STATEMENT xi Thank You for purchasing this Bloomfield Industries appliance. SPECIFICATIONS 1 FEATURES & OPERATING CONTROLS 2 Proper installation, professional PRECAUTIONS & GENERAL INFORMATION 3 operation and consistent AGENCY LISTING INFORMATION 3 maintenance of this appliance will ensure that it gives you the very INSTALLATION INSTRUCTIONS
ملخص المحتوى في الصفحة رقم 4
FEATURES AND OPERATING CONTROLS - AUTOMATIC BREWERS Fig. 1 Features & Operating Controls for Single Cup Brewers 2
ملخص المحتوى في الصفحة رقم 5
PRECAUTIONS AND GENERAL INFORMATION WARNING: ELECTRIC SHOCK HAZARD All servicing requiring access to non-insulated components must be performed by qualified service personnel. Do not open any access panels which require the use of tools. Failure to heed this warning can result in electrical shock. WARNING: INJURY HAZARD All installation procedures must be performed by qualified personnel with full knowledge of all applicable electrical and plumbing codes. Failure could
ملخص المحتوى في الصفحة رقم 6
INSTALLATION READ THIS CAREFULLY BEFORE STARTING THE INSTALLATION IMPORTANT: Unpack the unit. Inspect all components for completeness and To enable the installer to make condition. Ensure that all packing materials have been removed a quality installation and to from the unit. minimize installation time, the LEVELING THE UNIT following suggestions and tests should be done before the Verify that an adjustable leg is installed at each of the five actual unit install
ملخص المحتوى في الصفحة رقم 7
INSTALLATION (continued) PLUMBER’S INSTALLATION INSTRUCTIONS CAUTION: ELECTRICAL Brewer should be connected to a POTABLE WATER, COLD DAMAGE WATER line. Flush water line before connecting to Brewer. DO NOT plug in or energize this DO NOT use a saddle valve with a self-piercing tap for the water appliance until all Installation line connection. Such a tap can become restricted by waterline Instructions are read and debris. For systems that must use a saddle tap, sh
ملخص المحتوى في الصفحة رقم 8
INSTALLATION (continued) ELECTRICIAN’S INSTALLATION INSTRUCTIONS WARNING: SHOCK HAZARD REFER TO ELECTRICAL SPECIFICATIONS - Page 1 Check the nameplate to determine correct electrical service Brewer must be properly required for the Brewer to be installed. grounded to prevent possible shock hazard. DO NOT IMPORTANT: Before connecting to electricity, make sure assume a plumbing line will brewer is connected to the water supply. provide such a ground.
ملخص المحتوى في الصفحة رقم 9
OPERATION Fig. 4 Water Flow Diagram IMPORTANT: A. START-UP TANK MUST BE FULL For initial start-up, or if the brewer has not been used for an OF WATER BEFORE extended period of time: CONNECTING BREWER TO ELECTRIC POWER. ♦ Be sure the water supply is properly connected and the water supply valve is turned ON. Heating elements will be damaged if allowed to ♦ Be sure that TANK HEATER SWITCH is OFF before connecting
ملخص المحتوى في الصفحة رقم 10
OPERATION (continued) B. PROGRAM BREW VOLUMES ♦ Each BREW SELECT KEY is individually programmable. ♦ Keys may be programmed for pulse brewing to optimize contact times and extraction rates,. ♦ Up to 10 pulses may be programmed. Each pulse delay is fixed at 4 seconds. ♦ Dilution for each BREW SELECT KEY is individually programmable (usually us
ملخص المحتوى في الصفحة رقم 11
OPERATION - BREWING COFFEE 1. Unlock the pod holder by pulling the LOCKING LEVER fully CAUTION: forward. BURN HAZARD 2. Pull the BREW TRAY fully forward, then lower tray. Exposed surfaces of the brewer may be HOT to the NOTE: Normally, the brewer will automatically discard the last pod. If the brewer has not been used for some time, the used pod may touch, and can cause serious burns. need to be removed by hand. Deposit the used pod in
ملخص المحتوى في الصفحة رقم 12
CLEANING INSTRUCTIONS CAUTION: PROCEDURE: Clean Coffee Brewer BURN HAZARD PRECAUTIONS: Disconnect brewer from electric power. Brewing and serving Allow brewer to cool. temperatures of coffee and tea are extremely hot. FREQUENCY: Daily Hot beverage will cause serious skin burns. TOOLS: Mild Detergent, Clean Soft Cloth or Sponge Bristle Brush, Bottle Brush CAUTION: SHOCK HAZARD 1. D
ملخص المحتوى في الصفحة رقم 13
SANITIZING INSTRUCTIONS CAUTION: PROCEDURE: Sanitize Coffee Brewer BURN HAZARD PRECAUTIONS: None Brewing and serving temperatures of coffee and tea FREQUENCY: Weekly are extremely hot. Hot beverage will cause TOOLS: Pod Sanitizer Packet serious skin burns. Empty Container Sanitizing is necessary to 1. Unlock the pod holder by pulling the LOCKING LEVER fully remove those oils and other f
ملخص المحتوى في الصفحة رقم 14
TROUBLESHOOTING SUGGESTIONS SYMPTOM POSSIBLE CAUSE SUGGESTED REMEDY Water won’t heat Tank heater switch OFF Press switch to ON Brewer unplugged or circuit Check power supply cord breaker tripped Check / reset circuit breaker Temperature setpoint too low Set for desired temperature Hi-Limit safety switch tripped Allow to cool hi-limit will self-reset Damaged internal component or Examine wiring & connectors, wiring controller, water level probe and heating element Repair/replace as ne
ملخص المحتوى في الصفحة رقم 15
SERVICING INSTRUCTIONS ACCESS PANELS CAUTION: SHOCK HAZARD TOP PANEL: Opening access panels on this Remove top panel to access hot water tank, thermostat, heating brew may expose uninsulated elements, brew pump and tubing, brew solenoid, hot water electrical components. dispenser solenoid and piping, pod holders and brew tray, Disconnect brewer from Top panel is held by screws around the edge. electrical power before removing any panel. Remove pod
ملخص المحتوى في الصفحة رقم 16
SERVICING INSTRUCTIONS (continued) TEMPERATURE ADJUSTMENT CAUTION: SHOCK HAZARD Disconnect brewer from electric power. These procedures involve Pull vent tube out of tank lid and insert a thermometer of known exposed electrical circuits. accuracy in hole. Reconnect brewer to electrical power. These procedures are to be Place empty cup on the cup grid. Energize brewer and allow unit performed by qualified to heat. When READY light glows, read the temp
ملخص المحتوى في الصفحة رقم 17
SERVICING INSTRUCTIONS (continued) REMOVE TANK LID ASSEMBLY IMPORTANT: Before setting assembly into tank, make sure tank lid gasket is properly seated on flange of lid. DO NOT OVER-TIGHTEN. Fig. 8 Tank Lid Configuration IMPORTANT: Disconnect brewer from electric power. Turn OFF water supply. When mounting thermostat, be Remove top panel. Pull vent tube, inlet elbow and water level sure to insert sensing bulb to probe out of tank lid. Remove hi-l
ملخص المحتوى في الصفحة رقم 18
SERVICING INSTRUCTIONS (continued) REPLACE SOLENOID Symptom: Brewer will not flow water; or, brewer drips continuously from pod holder or brew nozzle. NOTE: Wrench p/n 86660 is designed to allow easy removal of flare nuts from the water inlet fitting IMPORTANT: Shut-off water to brewer and disconnect brewer from electric power before removing hoses or wiring. Remove water supply flare fitting: a. Slide the 5/8" end of the wrench over the flats on the
ملخص المحتوى في الصفحة رقم 19
SERVICING INSTRUCTIONS (continued) CLEAN UPPER POD HOLDER CAUTION: SHOCK HAZARD Remove drip tray assembly and pod drawer. Slide brew tray fully forward. DO NOT pour, spill or splash NOTE: Upper pod holder can be cleaned in place. It is not water onto, into or over any normally necessary to remove the pod holder from the carriage internal component. for cleaning. IMPORTANT: Remove retaining screw from spray disk. Remove disk from pod DO NOT use steel wool, shar
ملخص المحتوى في الصفحة رقم 20
SERVICING INSTRUCTIONS (continued) REPLACE CONTROLLER Disconnect brewer from electric power. Remove top panel Note location of wire connections. Be sure to mark the two keypad ribbon cables as to orientation. Disconnect wiring from IMPORTANT: controller. The two keypad ribbon cables connectors are not polarized Remove four nuts holding controller to cabinet. and can easily be installed in the wrong position. Be sure to mark the ribbon cable connec