ملخص المحتوى في الصفحة رقم 1
Radio-Controlled Clock with Barometer and
Projection (Model #: PS-S02/PS-S02U)
User Manual
EN
ملخص المحتوى في الصفحة رقم 2
Warnings ............................................................... 12 TABLE OF CONTENTS Troubleshooting ..................................................... 13 About this guide .................................................... 2 Specifications ........................................................ 14 Product overview ................................................... 3 Additional resources .............................................. 16 Getting started ............................
ملخص المحتوى في الصفحة رقم 3
In this box, you will find: ABOUT THIS GUIDE Congratulations on your selection of the Philippe Starck • Main unit with Oregon Scientific Radio Controlled Clock with • Batteries Barometer and Projection (PS-S02/PS-S02U). This • AC power adapter powerful device bundles time keeping, alarm, barometric trend, weather forecast, and projector features into a single tool you can use from the convenience of your home. Keep this manual handy as you use your new product. It contains practical step-by-ste
ملخص المحتوى في الصفحة رقم 4
DESCRIPTIONS PRODUCT OVERVIEW 1. Snooze/Light button ( 8, 11, 12) TOP AND BOTTOM VIEWS 2. Projection lens ( 11) 3. Reset button ( 6, 12) 4. DC power input jack ( 6) 1 5. Battery compartment ( 6) 2 3 4 5 3 EN
ملخص المحتوى في الصفحة رقم 5
LCD DISPLAY DESCRIPTIONS 1. Low battery icon ( 6) 2. Clock ( 7) 3. Weather forecast ( 11) 4. Calendar ( 9) 5. Radio signal icon ( 7) 6. Barometer ( 9) 7. Alarm ( 8) 4 EN
ملخص المحتوى في الصفحة رقم 6
BACK VIEW BUTTON DESCRIPTIONS 1. Up – increase setting / activate auto-synch ( 7) 2. Down – decrease setting / deactivate auto synch ( 7) 3. Select – switch modes / change settings ( 6) 4. Focus –focus projector ( 12) 5. Alarm –activate / deactivate alarm ( 8) 3 1 4 2 5 5 EN
ملخص المحتوى في الصفحة رقم 7
NOTE If the AC power becomes unavailable, the unit will GETTING STARTED automatically switch to battery power. BATTERIES SWITCH BETWEEN MODES Batteries are supplied with this product. Replace them Press SELECT. The selected mode will flash. The display whenever the low battery signal ( ) displays. Remove the will stop flashing if no key is pressed within 5 seconds. compartment lid on the bottom of the unit. Be sure to match the correct polarity, as shown in the battery compartment. CHANGE SET
ملخص المحتوى في الصفحة رقم 8
CLOCK Strong signal Weak signal No signal This product can automatically synchronize the date and time with official time-keeping organizations in Frankfurt, Germany (PS-S02) or Rugby, England (PS-S02U). When the unit is within 1500 km (932 miles) of a RF signal, the reception icon will blink. NOTE For best results, place the unit away from metal or electrical objects, and near a window with a clear view to RECEPTION the sky. Reception takes 2 – 10 minutes to complete. Once complete, the icon
ملخص المحتوى في الصفحة رقم 9
SET OR CHANGE THE CLOCK SET ALARM 1. Press SELECT several times until the Alarm area 1. Press SELECT to switch to the Clock Mode. The time will flash. flashes. 2. Press and hold SELECT for 2 seconds to enter the 2. Press and hold SELECT for 2 seconds to enter setting mode. the setting mode. 3. Select the hour and minute. Press UP or DOWN 3. Select the 12/24-hour format, hour, and minute. to change the setting. Press SELECT to confirm. Press UP or DOWN to change the setting. Press 4. Press
ملخص المحتوى في الصفحة رقم 10
TO TURN THE ALARM OFF OR ON 3. Select the year, month, date, and language. Press Press any button to stop the alarm. UP or DOWN to change the setting. Press SELECT to confirm. To turn the alarm off completely (deactivate it for the next day), press ALARM. NOTE The language options are (E) English, (F) French, (D) German, (I) Italian, and (S) Spanish. CALENDAR SET DATE BAROMETER Clock auto-synchronization must be deactivated before This product tracks barometric pressure changes over the you ma
ملخص المحتوى في الصفحة رقم 11
BAROMETRIC TREND VIEW THE LAST 24 HOURS The barometric trend arrow for the last 30 minutes is Press SELECT 2 times until the Barometer Area flashes. always displayed. Then, press UP or DOWN to view the last 24 hours history. Trend Description Pressure change SET UNIT AND ALTITUDE (mb/hPa) You can set the unit of measurement (mb/hPa or inHg) and altitude. Setting the altitude allows the product to take 1 hr 6 hrs more accurate barometric measurements. Rising +1 +3 1. Press SELECT 2 times until
ملخص المحتوى في الصفحة رقم 12
WEATHER FORECAST PROJECTOR This product forecasts the next 12 to 24 hours of weather This product has a built-in projector for viewing time and within a 30 to 50 km (19 - 31 mile) radius with 70 to 75 alarm status at night. percent accuracy. The weather forecast is always displayed. NOTE The maximum projection range is 2 meters (6 feet). The image gets larger the farther you display it. Partly Clear Cloudy Rainy Cloudy PROJECT TIME / ALARM STATUS In a darkened room, press SNOOZE/LIGHT to disp
ملخص المحتوى في الصفحة رقم 13
FOCUS IMAGE pen) whenever you change the batteries, or whenever The FOCUS switch is located on the back of the unit. performance is not behaving as expected (e.g., unable to Rotate to adjust. establish radio frequency link with automatic clock, etc.) This will return all settings to default value (barometric CONTINUOUS PROJECTION pressure history, alarm setting, etc.) The AC power adapter must be plugged in to use this feature ( 6). SAFETY AND CARE Wash the unit with a slightly damp cloth and mi
ملخص المحتوى في الصفحة رقم 14
• Never immerse the unit in water. This can cause TROUBLESHOOTING electrical shock and damage the unit. Check here before contacting our customer service • Do not subject the main unit to extreme force, department. shock, or fluctuations in temperature or humidity. • Do not tamper with the internal components. Problem Symptom Remedy • Do not mix new and old batteries or batteries of Calendar Strange date Change language different types. / month ( 9) • Do not use rechargeable batteries with this
ملخص المحتوى في الصفحة رقم 15
Problem Symptom Remedy Problem Symptom Remedy Projector No Plug in AC power Clock Cannot return to default. continous adapter ( 6, 12) 3. Replace batteries. projection 4. Place clock near Baro Strange Set altitude / unit window / away reading ( 10) from electrical devices, and wait 10 – 20 minutes. SPECIFICATIONS If it still fails, you may be too far from Dimensions: a signal. L x W x H 75 x 36 x 78.3 mm (3 x 1.42 x 3.08 in) Weight 212 grams with battery Cannot Disable auto- change synchronizat
ملخص المحتوى في الصفحة رقم 16
Barometer Calendar DD/MMM; weekday selection in 5 Unit mb/hPa or inHg languages (E, D, F, I, S) Range 500 to 1050 mb/hPa Alarm 2 minute crescendo (14.77 to 31.01 inHg) Snooze 8 minutes Resolution 1 mb (0.03 inHg) Altitude -100 to 2500 meters Projector (-328 to 8202 feet) Display Current time / alarm status Display Rainy, cloudy, partly cloudy, sunny Rotation image flip Memory 24 hour Focusing Manual Trend 1mb change in 1 hour or 3mb Projection 5-second or continuous change in 6 hours Power 3 x U
ملخص المحتوى في الصفحة رقم 17
ADDITIONAL RESOURCES Visit our website (www.oregonscientific.com) to learn more about your new product and other Oregon Scientific products such as digital cameras, hand-held organizers, health and fitness gear, and weather stations. The website also includes contact information for our customer service department, in case you need to reach us. 16 EN
ملخص المحتوى في الصفحة رقم 18
EC-DECLARATION OF CONFORMITY Additional information: This product complies with the essential requirements of The product is therefore conform with the Low Voltage Article 3 of the R&TTE 1999/5/EC Directives, if used for Directive 73/23/EC, the EMC Directive 89/336/EC and its intended use and that the following standard(s) has/ R&TTE Directive 1999/5/EC (appendix II) and carries the have been applied: respective CE marking. Efficient use of radio frequency spectrum VS-Villingen / Germany Augus