ملخص المحتوى في الصفحة رقم 1
The.Danger.signal.indicates.an.immediately.hazardous.situation.which,.
if.not.avoided,.will result.in.death.or.serious.injury.
The.Warning.signal.alerts.you.to.potential.hazards.or.unsafe.practices.which,.
if.not.avoided,.could result.in.severe.personal.injury.or.death.
The.Caution.signal.alerts.you.to.hazards.of.unsafe.practices.which,.if.not.avoided,.
may.result.in.minor.personal.injury.or.property.damage.
Please.be.certain.that.the.person.who.installs.or.uses.this.appliance.carefully.
reads.a
ملخص المحتوى في الصفحة رقم 2
Table of Contents Warranty...........................................................................................................4 Introduction/Typical Installation . Introduction.......................................................................................4 . Typical.Installation.............................................................................4 Waste Xpress Features...................................................................................5 WX-101A Control Featu
ملخص المحتوى في الصفحة رقم 3
Warranty WASTE XPRESS SYSTEM LIMITED WARRANTY ® ® The.InSinkErator .Waste.Xpress,.disposer.and.control.centers.are.warranted.against.defects.in.material.and. workmanship.for.one.year.from.the.date.of.installation..The.warranty.includes.parts.and.labor,.provided.an.. InSinkErator.Factory.Authorized.Service.Center.performs.the.service..This.warranty.does.not.apply.if.the.failure.. is.due.to:.faulty.or.improper.electrical.installation,.faulty.or.improper.plumbing.installation,.product.abuse.or.. mi
ملخص المحتوى في الصفحة رقم 4
Waste Xpress Features CONSTRUCTION FEATURES Stainless.steel.construction.(for.physical.size.see.. COMPACT.SIZE ® Figure.3). The.Waste.Xpress .is.designed.to.fit.under.a.34".high commercial.kitchen.table. WASTE.MIX The.Waste.Xpress.can.process.non-food.waste.such WASTE.REDUCTION as.paper,.light.and.rigid.plastic.or.food.wrappings.when Reduces.volume.by.85%. mixed.with.a.minimum.of.50%.food.waste. SAFETY.INTERLOCK The.Waste.Xpress.is.equipped.with.safety.interlock.. on.the.discharge.chute.(see.Fig
ملخص المحتوى في الصفحة رقم 5
WX-101A Control Features/Mounting Control Center ® The.WX-101A.Control.Center.is.UL .approved.for.use. with.InSinkErator.Waste.Xpress.food.waste.reduction. systems..The.control.center.operates.the.disposer.and. ELECTRICAL SHOCK Waste.Xpress..Its.main.functions.are: .•.Ensure.that.Waste.Xpress.voltage.and.phase. match.that.of.the.electrical.supply,.control.center.. •.To.start.and.stop.the.disposer/Waste.Xpress.system. &.disposer..Check.nameplate.for.specification. •.To.reverse.the.direction.of.th
ملخص المحتوى في الصفحة رقم 6
Installing Disposer CLEAN.THE.DRAIN.LINE With.a.drain.line.auger,.clear.away.all.hardened.waste material.in.the.horizontal.drainpipe.running.from.the PERSONAL INJURY drain.trap.to.the.main.waste.line. .•.For.safe.operation,.The.minimum.required.distance . from.the.table.top.or.trough.to.the.mounting.flange. is.6.inches.for.standard.body.disposers.. (as.specified.by.UL)..See.Figure.5. 6" min. (152.4 mm min.) .•.Moving.shredder.parts.may.cause.serious.injury.if. a.hopper.or.cone.is.not.properly.in
ملخص المحتوى في الصفحة رقم 7
InSinkErator Mounting Assemblies 4..From.the.bottom,.insert.two.screws.through.opposite STANDARD MOUNTING ASSEMBLY . sides.of.the.flat.gasket.(3).and.mounting.flange,.into 1..Place.mounting.flange.(1).over.the.existing.collar . the.threaded.fasteners.in.the.existing.flange..The . adaptor.connection.lip.or.sink.bowl.flange.(this.may . flat.gasket.is.used.only.in.the.#6.mounting.assembly. . require.some.force). . The.screws.should.protrude.about.1/4".below.the 2..Push.the.mounting.flange.up.out.of
ملخص المحتوى في الصفحة رقم 8
Installing the Waste Xpress 45˚ bend shown (max of 4 can be used) 1-1/2" 3" (38.1 mm) (76.2 mm) Figure 11. Top View Syphon Breaker Sink Bowl Cold Water Solenoid Hot Water Solenoid Waste Xpress 1-1/2" min 1" min (38.1 mm (25.4 mm min) min) Disposer Flow Control Valve Shut Off Valve (supplied by others) WX-101A Controller 10 max (3.1 m max) Figure 12. Typical Installation Diagram 9
ملخص المحتوى في الصفحة رقم 9
Installing the Waste Xpress 7....Connect.wire.bundle.between.WX-101A.and.. WASTE XPRESS LOCATION Waste.Xpress.unit.as.detailed.in.wiring.diagram.. NOTE: Prior to installing the Waste Xpress the Door.interlock.connections.are.#3.and.#95..Replace. disposer and control center should be installed as terminal.cover. specified within this manual. 8....Wire.per.local.electrical.codes.and.install.. •.Position.Waste.Xpress.within.10.feet.of.the.disposer using.NEMA.4.watertight.electrical.connectors.. out
ملخص المحتوى في الصفحة رقم 10
Plumbing Connections PROPERTY DAMAGE Water.connections.must.comply.with.all.local. plumbing.codes. WASTE INLET LINE Connect.the.disposer.outlet.flange.as.close.as.. possible.and.with.as.few.as.possible.90°.elbows.to.. the.Waste.Xpress.inlet. NOTE: The maximum allowable distance between the Figure 15. disposer outlet flange and the Waste Xpress inlet is 10 feet with a maximum of four (4) 90° elbows. 1..Connect.the.disposer.outlet.to.the.Waste.Xpress.. . inlet.using.2".NPT.plumbing..3.HP.will.re
ملخص المحتوى في الصفحة رقم 11
Plumbing Connections WASTE OUTLET LINE WATER SUPPLY CONNECTIONS Connect.a.2".drain.line.to.the.Waste.Xpress.waste.. When.connecting.the.incoming.water.supply.to.the outlet.as.specified.per.local.codes.(see.Figure.18.. disposer,.sink.bowl.and.Waste.Xpress,.use.as.few for.water.outlet.location). elbows.and.tees.as.possible. InSinkErator.recommends.that.the.water.outlet.. All.cold.water.line.fittings.are.1/2".NPT.except.the empties.into.a.floor.drain. sink.bowl.nozzles.which.are.1/2".compression...
ملخص المحتوى في الصفحة رقم 12
Electrical Connections ELECTRICAL SHOCK PROPERTY DAMAGE .•.Turn.off.all.electrical.supply.to.the.disposer.before. .•.Ensure.that.control.center.voltage.and.phase attempting.any.work.on.it..Use.a.voltmeter.or.. . match.the.disposer.motor.and.electrical.supply... circuit.tester.to.ensure.that.power.is.off. . Check.nameplates.on.disposer.and.control.. . center.for.voltage.and.phase.specifications. .•.All.Installation.work.must.conform.to.local.. plumbing.and.electrical.codes. .•.Refer.to.the.contro
ملخص المحتوى في الصفحة رقم 13
Operating Instructions PRE-OPERATION TEST Before.operating.the.Waste.Xpress.complete.. the.following.steps.to.ensure.the.unit.has.been.. PERSONAL INJURY properly.installed. If.system.does.not.shut.down.when.front.. cover/discharge.chute.is.removed,.interlock.may. 1....Ensure.plumbing.and.electrical.connections.. not.be.wired.correctly..See.Troubleshooting.section. are.secure. for.corrective.action. 2....Turn.on.incoming.cold.water.supply.to.disposer.. and.hot.water.supply.to.the.Waste.Xpress. 3.
ملخص المحتوى في الصفحة رقم 14
Operating Instructions TO.START 1..Check.to.ensure.disposer.is.free.of.foreign.objects. 2..Ensure.power.is.on. 3..Push.start.button..Disposer.and.Waste.Xpress.will. run.and.water.will.flow.into.disposer TO.STOP 1..Push.stop.button..System.will.stop. 2..Water.may.continue.to.flow.into.disposer.for.up.to.. 10.minutes,.per.the.time.set.on.the.water.shutoff. delay.timer..This.post-flush.clears.the.drain.lines.. of.food.waste. WATER.SHUTOFF.DELAY.ADJUSTMENT This.water.shutoff.delay.is.adjustable.from
ملخص المحتوى في الصفحة رقم 15
Operating Instructions OPERATING WASTE XPRESS SYSTEM 1..Make.sure.there.are.no.foreign.objects.in.disposer. grind.chamber..Do.not.pre-load.disposer.with.food. waste.prior.to.starting. 2..Place.10.gallon.waste.bin.under.discharge.chute. 3..Push.start.button.on.control.center..Waste.Xpress. and.disposer.will.run.and.water.will.flow.into.disposer. 4..Feed.food.waste.into.disposer.in.a.steady,.. continuous.flow..Waste.will.exit.discharge.chute.. and.drop.into.waste.bin. NOTE: Once all waste has been
ملخص المحتوى في الصفحة رقم 16
Cleaning Instructions PERSONAL INJURY Discharge Chute Wait.until.auger.paddles.stop.before.cleaning. Waste.Xpress. 1....Press.stop.button.on.control.center.to.stop.system. (disposer.&.Waste.Xpress). 2....Holding.both.handles.remove.discharge.chute.by.. tilting.it.upward.(see.Figure.25). 3....Remove.auger-bearing.bracket.by.sliding.the.two. captive.fasteners.inward.and.then.pull.bracket.. Figure 25. upward.(see.Figure.26.and.27). 4....Lift.auger.and.screen.up.and.then.out.. (see.Figure.26). 5....
ملخص المحتوى في الصفحة رقم 17
Troubleshooting ELECTRICAL SHOCK PERSONAL INJURY •.Disconnect.power.before.servicing. Wait.until.auger.paddles.stop.before.servicing. Waste.Xpress. •.Do.not.bypass.interlock.switch. Troubleshooting.for.problems.other.than.what.is.listed.below.should.be.performed.by.a.qualified.service.person.. Troubleshooting.performed.by.untrained.personnel.could.result.in.electrical.shock.or.damage.to.the.Waste.Xpress,. disposer.and/or.Control.Center. SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION The.
ملخص المحتوى في الصفحة رقم 18
Troubleshooting SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Water.backs.up.into.disposer.. •. The.auger.and.screen.plugged. •. Remove.plug. (does.not.drain). •. Auger.not.turning.. •. Ensure.that.auger.is.seated.properly.and.. . that.auger.belt.in.place..Check.motor. •. Plumbing.line.between.disposer.and.. •. Remove.clog. . Waste.Xpress.clogged. Waste.Xpress,.disposer.and.water. •. Insufficient.time.allowed.after.Line.. •. Allow.15-20.seconds.prior.to.attempting.. will.start.when."sta
ملخص المحتوى في الصفحة رقم 19
Troubleshooting SYSTEM TROUBLESHOOTING PROBLEM POSSIBLE CAUSE SOLUTION No.water.spraying.onto.. •. Solenoid.valve.clogged. •. Remove.clog. auger.screen. •. Water.turned.off. •. Turn.on.water. •. Solenoid.valve.defective. •. Call.for.service. •. Spray.nozzles.clogged. •. Replace.nozzles. •. Timer.defective. •. Call.for.service. •. Timer.not.set.properly. •. Call.for.service. •. Solenoid.valve.installed.incorrectly. •. Reinstall.solenoid.valve.so.arrow.is.pointing. . in.correct.direction. Water.fl
ملخص المحتوى في الصفحة رقم 20
Troubleshooting DISPOSER TROUBLESHOOTING PROBLEM CAUSE SOLUTION Disposer.motor.will.not.start.and. •. No.incoming.line.power. •. Turn.line.power.on. water.does.not.flow. •. Line.disconnect.switch.is.not.on.. •. Turn.line.disconnect.to."on".position..Wait.. . . 15-20.seconds.before.attempting.to.start.. . system.to.allow.control.to.perform."self.test." •. Line.disconnect.switch.has.been.. •. Wait.30.seconds.and.try.starting.again.. . reactivated.and.30-second.delay.. . . has.not.yet.expired. •. L