ملخص المحتوى في الصفحة رقم 1
RHR-HEX, RHR2-HEX, RHR 1/2 HEX
Island Hot Food Case
P/n IGHt -RHR-HeX, RHR2HeX2, RHR 1/2 HeX, RHR sQUaRe-0608
INSTALLATION & OPERATION GUIDE
/CHINO
Installation
& operation
RHR-HEX, RHR-HEX2, RHR 1/2, RHR-SQ Manual
Island Hot Food Case
Rev. 0608
ملخص المحتوى في الصفحة رقم 2
IGHt -RHR, RHR2-HeX-0608 General Instructions t able of Contents this Booklet Contains Information on: General Instructions.....................................................2 The RHR-HEX is a self-service Hot Food Hexagon-shaped Cut and Plan views ......................................................3 Island Stand, available in 4 and 6 foot sizes. Installation .....................................................................3 The RHR2-HEX is a similar unit, with the addition of a Level
ملخص المحتوى في الصفحة رقم 3
Rev. 0608 Cut and Plan views Food Warmer 3 18 /4" Food Food Light Light Warmer Warmer Warming Warming Griddle Griddle 1 1 1 1 28 /2" (19 /2") 28 /2" (19 /2") Control Control Panel Panel 1 1 1 1 1 1 1 1 43 /4" (25 /8") 10 /2" 10 /2" 10 /2" 10 /2" 43 /4" (25 /8") 1 1 1 3 64 /4" (47 /8") 54 /4" (47 /8") RHR2-HEX 6' & (4') RHR-HEX 6' & (4') Self-Service Hot Self-Service Hot Scale = 1/2" 1 12 /4" ELEC. MECHANICAL STUB UP AREA 4" X 6" 1 1 2'-2 /2" (3'-1 /2") 7 3 4'-6 /16" (6'-5 /8") RHR-HALF-HEX-4' (
ملخص المحتوى في الصفحة رقم 4
IGHt -RHR, RHR2-HeX-0608 Installation (Cont'd) Bumper Installation Instructions Step 2: Use silicone lubricant to help the Step 1: Make sure the aluminum channel and end caps bumper slide into the channel. are installed. Step 3: Starting on one end: while inserting the bumper, Step 4: As you insert the bumper into the channel with push it up against the end cap to prevent one hand, pull the bumper toward you with the bumper from shrinking after installation the other to
ملخص المحتوى في الصفحة رقم 5
Rev. 0608 Installation (Cont'd) Boston series 2000 NOTE: Flexible top: Over cut vinyl 1/8" for every 4' section for the flexible top to ensure a proper fit. note: Rigid t op: do not over cut. 1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pre-slotted holes in both the end cap and the base. Insert screws through the two holes of end cap and tighten. 2a. Flexible t op: Butt end of the vinyl top against end/corner cap. While applying p
ملخص المحتوى في الصفحة رقم 6
IGHt -RHR, RHR2-HeX-0608 Installation (Cont'd) Boston 2000 eco series 1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pre-slotted holes in both the end cap and the base. Insert screws through the two holes of end cap and tighten. 2a. Flexible t op: Butt end of the vinyl top against end/corner cap. While applying pressure, bend back vinyl top so that vinyl legs are positioned within the base grooves. Roll vinyl top over full length of b
ملخص المحتوى في الصفحة رقم 7
Rev. 0608 Installation (Cont'd) Boston 1000 series NOTE: Flexible top: Over cut vinyl 1/8" for every 4' section for the flexible top to ensure a proper fit. note: Rigid t op: do not over cut. Installation 1. Attach the base and end/corner cap to the desired surface by inserting #8 pan head screws through the pre-slotted holes in both the end cap and the base. Insert screws through the two holes of end cap and tighten. 2a. Flexible t op: Butt end of the vinyl top against end/corner cap. Whi
ملخص المحتوى في الصفحة رقم 8
IGHt -RHR, RHR2-HeX-0608 electrical Wiring Color Code Field Wiring and serial Plate amperage Field Wiring must be sized for component amperes printed on the serial plate.Actual ampere draw may be less than specified. Case amperes are listed on the wiring diagram, but due to parts availability they may vary slightly. Always check the serial plate for the actual loads. Ballast location Ballast Ballast (one for each light) Control Panel Electrical Circuit Identification Standard lighting for al
ملخص المحتوى في الصفحة رقم 9
Rev. 0608 User Information Food Handling • Using thermometer, check product before loading These hot tables are for short-term holding and display of in case (150°F-160°F). precooked hot foods. They are not intended to cool or reheat • At start, set lamps to “3”.After loading, recheck food. The temperature of the food should be approximately temperature every 1/2 hour to see that unit is 160°F when first put into the hot table. Any attempt to use operating properly.Adjust the thermostat
ملخص المحتوى في الصفحة رقم 10
IGHt -RHR, RHR2-HeX-0608 User Information (Cont'd) Cleaning Instructions Waxing 1 . Turn temperature control knobs to OFF position. If after removing dirt and grease, the acrylic can be waxed 2. Allow unit to cool completely. with a good grade commercial wax. This will improve 3. Wipe entire unit with clean cloth and mild detergent. the appearance of the surface by filling in most minor scratches. Wax should be applied in a thin even coat, and The EXTERIOR surfaces of these hot tables must
ملخص المحتوى في الصفحة رقم 11
Rev. 0608 Maintenance 1. Turn light switch to OFF before replacing any lighting components. 2. Disconnect light fixture by removing power cord from socket in the right rear interior corner of the merchandiser. 3. Place the shelf on a flat surface to remove the clear plastic protective shield from the fixture. Carefully ALWAYS DISCONNECT ELECTRICAL POWER insert one finger between the fixture socket and AT THE MAIN DISCONNECT WHEN SERVICING the protective shield. Use other hand to “pin
ملخص المحتوى في الصفحة رقم 12
IGHt -RHR, RHR2-HeX-0608 electrical Wiring diagrams RHR-HeX RHR-HEX 4’ W6100012 5’ 6” W6100002 RHR-HEX-2 (w/shelf) OLD► 4’ W6100003 NEW ► 4’ W6100020 6’ W6100015 RHR-Square 4’ W6100005 RHR-1/2-HEX 4’ W6100007 6’ W6100008 12
ملخص المحتوى في الصفحة رقم 13
Rev. 0608 Wiring diagrams 13 Loads, amp 208 V 240 V L1 19.7 22.8 Griddle L2 14.2 16.4 (6) 206W/220VAC Flexible Heater Pad #225-01-6770/-6770T L3 0.0 0.0 Overhead Lighting INCANDESCENT LAMPS Note: Case MUST be grounded GE APPLIANCE BULB PC15206-100A15-CD1-100 WATT- 115V (6) 125-03-1206 100WATT INCANDESCENT LAMP (6) 125-01-0287 LIGHT SOCKET Overhead Heating Element HE-04-68" #125-01-3235 Ledge Lights-optional 2700 W / 240 VAC COOLING Electronic FAN T-Stat MOTOR H1 H2 P1 POWER 1 2 3 4 5 6 7 M
ملخص المحتوى في الصفحة رقم 14
IGHt -RHR, RHR2-HeX-0608 Wiring diagrams (Cont'd) 14 LOADING 208 V 240 V L1 21.1 23.9 GRIDDLE L2 9.8 11.3 HEATING PADS - 451W 1.88A @ 240 VAC - EA. L3 8.2 9.4 OVERHEAD CANOPY INSTALLATION (6) 225-01-6771 INCANDESCENT LAMP 6180W @ 240VAC BULB 60W 115V (6) 125-03-1206 4695W @ 208VAC TUBULAR HEATER 125-01-3247A 2250W 9.4A @ 240 VAC INFINITE SENSOR CONTROL 225-01-3228 125-01-1663 COOLING TEMP. CONTROL H1 H2 FAN MOTOR .18A @ 120VAC P L1 L2 125-01-2012-A (2) 15 AMP FUSE L 125-01-8604 MAIN POWER FUSE
ملخص المحتوى في الصفحة رقم 15
Rev. 0608 Wiring diagrams (Cont'd) 15 LOADING 208 V 240 V L1 16.0 18.1 L2 13.1 14.6 Griddle L3 (2) sets of 3 pads - 206 W / 220 VAC Shelf Installation Fluorescent Double Biax Lamps (6) F13DBX23T4/SPX35 Overhead (crown) Installation Fluorescent Double Biax Lamps (3) F13DBX23T4/SPX35 Cal-Rod 1200W / ~240V Cal-Rod 980W /~240V Bulb Sensor #225-01-3301A Ballast 4111F2RP NGT 11S11T444 Safety T-Stat ON: 183°F Overhead OFF:210°F Ballast Cooling Temp. Control Electronic T-Stat Infinite M Infinite Con
ملخص المحتوى في الصفحة رقم 16
IGHt -RHR, RHR2-HeX-0608 Wiring diagrams (Cont'd) 16 LOADING 5328W @ 240VAC 208 V 240 V 4118W @ 208VAC L1 19.8 22.2 L2 15.3 17.7 NOTE: CASE MUST GRIDDLE TUBULAR HEATER TUBULAR HEATER BE GROUNDED HEATING PADS - 206W .86A @ 240 VAC - EA. 125-01-0478A 125-01-1006A (6) 225-01-6770 1200W 5A @ 240VAC 1800W 7.5A 240 VAC SHELF INSTALLATION INCANDESCENT LAMP BULB 60W 115V (6) 125-03-1206 OVERHEAD CANOPY INSTALLATION TEMP. CONTROL TEMP. CONTROL INCANDESCENT LAMP BULB 60W 115V (3) 125-03-1206 P1 P1 1 2 3
ملخص المحتوى في الصفحة رقم 17
Rev. 0608 Wiring diagrams (Cont'd) 17 LOADING 208 V 240 V L1 24.5 28.3 L2 18.6 21.4 L3 16.1 18.6 NOTE: CASE MUST BE GROUNDED SHELF INSTALLATION GRIDDLE OVERHEAD CANOPY INSTALLATION (2) SETS OF 3 FLEXIBLE HEATING PADS - 451W / ~240 VAC - EA. INCANDESCENT LAMPS INCANDESCENT LAMPS TUBULAR HEATER TUBULAR HEATER GE APPLIANCE BULB PC15206-100A15-CD1-100 WATT- 115V GE APPLIANCE BULB PC15206-100A15-CD1-100 WATT- 1 125-01-3247A 125-01-1006A (6) 125-03-1206 100WATT INCANDESCENT LAMP 980W / ~240 VAC (6)
ملخص المحتوى في الصفحة رقم 18
IGHt -RHR, RHR2-HeX-0608 Wiring diagrams (Cont'd) 18 LOADING OVERHEAD LIGHTS BALLAST MAGNETEK FLUORESCENT DOUBLE 208 V 240 V 4111F2RP BIAX LAMPS (8) 125-01-3240 L1 20.6 26.5 (8) F13DBX23T4/SPX35 L2 18.1 23.9 L3 ~ ~ NOTE: CASE MUST BE GROUNDED GRIDDLE HEATERS - THERMOFLEX™ (4) 364W @ ~240 VAC 225-01-6790T OVERHEAD HEATER WATLOW™ HE-08 SENSOR (1) 3550W @ ~ 240 VAC 225-01-3228 125-01-3243 BALLAST SAFETY T-STAT TEMP. CONTROL NGT CONTROLS™ 11S11T444 ON: 183°F / OFF: 210°F 225-01-3301A OVERHEAD COOLI
ملخص المحتوى في الصفحة رقم 19
Rev. 0608 Wiring diagrams (Cont'd) 19 LOADING 208 V 240 V L1 9.0 10.2 L2 7.2 8.3 Griddle L3 (3) Heater Pad 206 W / 220 VAC 225-01-6770 / ...-6770T Overhead Installation (3) Compact Double Biax Lamps Cal-Rod Htr 1250 W / 240 VAC HE-07 #125-01-3242 F13DBX23T4/SPX35 Bulb Temp Control #225-01-3301A NGT 11S11T444 Safety Limit B B B Electronic ON: 183°F T-Stat OFF: 210°F P1 Overhead 1 2 3 4 5 6 7 Infinite Ballast Cooling Control H2 H1 Ballast M 4111F2RP L2 L P L1 Pilot L Light DPSTRelay, 25A Pow
ملخص المحتوى في الصفحة رقم 20
IGHt -RHR, RHR2-HeX-0608 Wiring diagrams (Cont'd) 20 LOADING 208 V 240 V L1 14.8 17.1 L2 16.5 18.8 L3 Overhead Lights Fluorescent Double Biax Lamps (6) F13DBX23T4/SPX35 Overhead Heating Element (2) 2500 W / 240 VAC Griddle Heaters Pads (2) sets of 3 pads - 451 W / 220 VAC #225-01-3301A NGT 11S11T444 Bulb Safety Limit Sensor ON:183°F OFF: 210°F Overhead Ballast Cooling Temp. Control Electronic T-Stat M H1 H2 P1 (6) Ballast 4111F2RP 1 2 3 4 5 6 7 P L1 L2 L L s Pilot Light Pilot Light L1 L2 L3 N G