DO NOT
DISCARD
Installation
Instructions
Models:
Installation and service of this
appliance should be performed by
GO24MTCH
qualifi ed personnel. Hearth & Home
GO30MTCH
Technologies suggests NFI certifi ed
Listing #1238
or factory-trained professionals,
Grand Oak Match Light
Complies with LARGA2-72
or technicians
Gas Log Sets
supervised by
an NFI certified
professional.
Check with your local building code agency before you begin installation to ensure compliance with local codes, inclu
ملخص المحتوى في الصفحة رقم 2
Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. Congratulations Congratulations on selecting a Hearth & Home Technologies The information contained in this owner’s manual, unless gas log set—an elegant and clean alternative to burning noted otherwise, applies to all models and gas control wood. The Hearth & Home Technologies gas log set you systems. have selected is designed to provide the utmost in safety, Your new gas l
ملخص المحتوى في الصفحة رقم 3
WARNING WARNING Improper installation, adjustment, alteration, service HOT! DO NOT TOUCH. or maintenance can cause injury or property damage. SEVERE BURNS MAY RESULT. Refer to the owner’s information manual provided with CLOTHING IGNITION MAY RESULT. this appliance. For assistance or additional information Glass and other surfaces are hot during consult a qualifi ed installer, service agency or the gas operation and cool down. supplier. • Keep children away. CAUTION • CAREFULLY SUPERVISE
ملخص المحتوى في الصفحة رقم 4
• This appliance must have a screen in place while the appliance is in operation and, unless other provisions for WARNING combustion air are provided, the screen shall have an Fire Risk opening for introduction of combustion air. Explosion Risk • Solid fuels shall not be burned in a fi replace where a Verify inlet pressures. decorative appliance is installed. • High pressure may cause overfire • If glass doors are present, the glass doors must be fully condition. opened while appliance is i
ملخص المحتوى في الصفحة رقم 5
G. Negative Pressure WARNING Negative pressure results from the imbalance of air avail- able for the fi replace to operate properly. Causes for this Asphyxiation Risk imbalance include: This appliance produces carbon monoxide • Exhaust fans (kitchen, bath, etc.). (CO). • Range hoods. • The free opening areas (in square inches) • Combustion air requirements for furnaces, water heaters of the chimney damper as shown in the and other combustion appliances. following tables must be met. • Clothe
ملخص المحتوى في الصفحة رقم 6
H. Inspect the Appliance and Components • Remove the contents from the carton labeled “Burner”. Attached to the burner are tags identifying the manufacturer name, serial number, model number (including gas log size), BTU ratings, gas type, etc. • Review the attached tags before proceeding. Ensure that all minimum fi replace dimension requirements are achieved using Table 3. See Figure 1. Ensure the gas type provided in the fi replace coincide with the gas type marked on the tag. Figure 1 Me
ملخص المحتوى في الصفحة رقم 7
I. For Natural Gas Installation • Pour sand into the burner pans to the point where the burner pipe is covered. See Figure 3. Level the sand from right to left to ensure an even fl ame pattern. At this point the pan should be half full. Figure 5 Placing Rock Wool • Remove the Platinum Bright Embers™ from the package. Figure 3 Sand For optimum performance peel each piece apart in layers and lightly place on top of the vermiculite and rock wool where the fl ame is blue. This will achieve the
ملخص المحتوى في الصفحة رقم 8
J. Damper Stop Installation Instructions Included in the burner assembly box is a damper stop clamp which attaches to the damper as shown (Figure 6). Install the clamp to the damper ensuring that the minimum require- ments (Tables 1 and 2) are achieved. Use a 7/16 in. wrench to secure the clamp to the damper. If the damper clamp pro- vided does not fi t your application, other means of securing the proper opening must be provided by the installer. Damper Stop Clamp Damper Figure 6 Damper Stop
ملخص المحتوى في الصفحة رقم 9
K. 24 in. Grand Oak Series Logs (GO24) • Open the log box and remove the paper packaging and logs. • Inspect each log for breakage that may have occurred during shipping and handling. SRV736 SRV738 SRV737 SRV722 SRV723 SRV728 SRV724 SRV742 SRV729 SRV743 SRV727 Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev C • 12/05 9
ملخص المحتوى في الصفحة رقم 10
L. 24 in. Grand Oak Series (GO24) Log Placement Instructions • Place logs EXACTLY as the following photos depict. WARNING Fire Risk Explosion Risk Personal Injury Risk Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury. Step 1 SRV737 SRV736 SRV738 Step 2 SRV722 SRV723 Step 3 SRV729 SRV728 SRV724 SRV742 SRV743 SRV727 not shown. See page 12, Step 3 for placement o
ملخص المحتوى في الصفحة رقم 11
M. 30 in. Grand Oak Series Logs (GO30) • Open the log box and remove the paper packaging and logs. • Inspect each log for breakage that may have occurred during shipping and handling. SRV720 SRV726 SRV721B SRV721A SRV722 SRV723 SRV728 SRV724 SRV742 SRV740 SRV743 SRV727 Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev C • 12/05 11
ملخص المحتوى في الصفحة رقم 12
N. 30 in. Grand Oak Series (GO30) Log Placement Instructions • Place logs EXACTLY as the following photos depict. Step 1 SRV721A SRV721B SRV726 SRV720 Step 2 SR SRV722 V722 SRV723 SRV724 Step 3 SRV740 SRV728 SRV743 SRV742 SRV727 12 Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev C • 12/05
ملخص المحتوى في الصفحة رقم 13
O. Inspect the Venting System The fi replace venting system is designed and constructed to develop a positive fl ow adequate to remove fl ue gases to the outside atmosphere. See fi replace installation instructions. A spillage test must be made before the installed appliance is left with the consumer. • Close all doors and windows in the home. • Light the log set (see Lighting Instructions). • After three minutes, test with a smoke match, smoke candle, stick incense or cigarette 1 in. below the
ملخص المحتوى في الصفحة رقم 14
P. Lighting Instructions- Match Light WARNING Asphyxiation Risk Gas-burning appliances produce smoke and carbon monoxide gas during operation. • The damper must be open • The chimney must draw properly These fumes can be harmful if not vented properly. FOR YOUR SAFETY READ BEFORE LIGHTING FOR YOUR SAFETY READ BEFORE LIGHTING WARNING! IF THESE INSTRUCTIONS ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE. A. This appliance has a
ملخص المحتوى في الصفحة رقم 15
Q. Cleaning and Maintenance Instructions Always remember: • Do not place any combustible material near the appliance. • Do not place any paper, trash or other material on the log set or in the heater. • Do not touch any part of the appliance when it is in operation. • Do not operate this appliance without the fi replace screen closed. CAUTION Before cleaning the appliance, be sure it is turned completely off. The appliance must be completely cooled. Your appliance is designed to be virtuall
ملخص المحتوى في الصفحة رقم 16
R. Fequently Asked Questions Can I close the glass doors on my fi replace when using my gas logs? No. The gas log sets are designed for use in fi replaces with all fi replace doors fully opened. Operating your log set with the doors closed will cause overheating, premature failure of valve systems, and will void the warranty of your log set. What sort of maintenance do gas logs require? Vented gas logs do not require regular maintenance. However, it is a good idea to have valves, pilots and gas co
ملخص المحتوى في الصفحة رقم 17
S. Replacement Parts Grand Oak Gas Logs Service Parts Exploded Parts Diagram Beginning Manufacturing Date: N/A MTCH GO Gas Logs Ending Manufacturing Date: Active 4 3 2 1 5 Hearth & Home Technologies • Grand Oak Match Light Gas Log Sets • 4004-300 Rev C • 12/05 17
ملخص المحتوى في الصفحة رقم 18
Grand Oak Gas Logs Service Parts Service Parts List Beginning Manufacturing Date: N/A MTCH GO Gas Logs Ending Manufacturing Date: Active # Description of Part 24 in. 30 in. Qty. 1 Grate Assembly GR-300-24 GR-300-30 1 2 Burner Pan Assembly BPA-300-24 BPA-300-30 1 3 Connector FT-1-24 FT-1-30 1 4 Bottom Burner Orifi ce NG BPO-2-40 BPO-2-38 1 5 Top Burner Orifi ce NG BPO-2-26 BPO-2-26 1 Sand (NG only) 4004-108 4004-108 2 Vermiculite 4004-109 4004-109 2 Lava Rock 4004-110 4004-110 2 Rock Wool 4004-
ملخص المحتوى في الصفحة رقم 19
T. Warranty DECORATIVE GAS LOG LIMITED WARRANTY Hearth & Home Technologies Inc. (HHT) extends the following warranty for decorative gas log sets as described herein, while it is in its loca- tion or original installation. Dealers and employees of HHT have no authority to make any warranty or authorize any remedies in addition to or inconsistent with the terms of this Program. This warranty gives you specifi c legal rights. You may also have other rights which vary from state to state. LIMITE
ملخص المحتوى في الصفحة رقم 20
DO NOT DISCARD U Contact Information Please contact your Hearth & Home Technologies dealer with any questions or concerns. For the number of your nearest Hearth & Home Technologies dealer, please call 1-800-927-6841 or 1-888-427-3973. - NOTES - CAUTION DO NOT DISCARD THIS MANUAL • Read, understand • Leave this manual with • Important operating and follow these party responsible for and maintenance instructions for safe use and operation. instructions included. installation and operation.