ملخص المحتوى في الصفحة رقم 1
User Manual
ملخص المحتوى في الصفحة رقم 2
TABLE OF CONTENTS 1. Before You Begin ...................................................................................................... 3 What Is Included ......................................................................................................................... 3 Unpacking Instructions ................................................................................................................ 3 Claims .................................................................
ملخص المحتوى في الصفحة رقم 3
1. BEFORE YOU BEGIN What Is Included Ø 1 x Hurricane™ 1100 Ø 1 x FC-M Wired Manual Remote Ø Power Cord Ø 1 x Warranty Card Ø 1 x Quick Reference Guide Unpacking Instructions Immediately upon receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows
ملخص المحتوى في الصفحة رقم 4
Safety Instructions Please read the following notes carefully because they include important safety information about the installation, usage, and maintenance of this product. · Please keep this User Guide for future consultation. If you sell the unit to another user, be sure that they also receive this instruction booklet. · Always make sure that you are connecting to the proper voltage, and that the line voltage you are connecting to is not higher than that stated on the decal or r
ملخص المحتوى في الصفحة رقم 5
2. INTRODUCTION Product Overview Hanging bracket Fluid container Safety cable eye bolt Tilt Adjustment knob Heater Nozzle Manual Fog Low Fluid button indicator Fluid level indicator Manual Controller Wireless Controller Power input (hardwired) Fuse holder Hurricane™ 1100 User Manual 5 Rev. 7
ملخص المحتوى في الصفحة رقم 6
Product Dimensions 242 mm / 9.5 in 258 mm / 10.2 in Hurricane™ 1100 User Manual 6 Rev. 7 225 mm / 8.9 in
ملخص المحتوى في الصفحة رقم 7
3. SETUP AC Power To determine the power requirements for a particular fixture, see the label affixed to the back plate of the fixture or refer to the fixture’s specifications chart. A fixture’s listed current rating is its average current draw under normal conditions. All fixtures must be powered directly off a switched circuit and cannot be run off a rheostat (variable resistor) or dimmer circuit, even if the rheostat or dimmer channel is used solely for a 0% to 100% switch. Before
ملخص المحتوى في الصفحة رقم 8
Mounting Orientation This fixture should only be mounted/used on a flat surface. This fixture may not be tilted. Rigging It is important never to obstruct the vents’ pathways. Mount the fixture using, a suitable “C” or “O” type clamp. · When selecting installation location, take into consideration the fluid reservoir access and routine maintenance. · Safety cables must always be used, utilizing the provided safety eye bolt. · Never mount in places where the fixture will be exposed t
ملخص المحتوى في الصفحة رقم 9
4. OPERATING INSTRUCTIONS This mode will allow you to control the fogger manually, set the fog machine to run continuously, or to set the fog machine to run off bursts with adjustable interval and duration settings. Manual Remote Operation (FC-M) (Standard) 1. Plug in the fog machine to power. 2. Plug in the M remote to the Manual Controller socket on the rear of the fog machine. 3. Press the single button located on the remote to trigger the fog output. The button is momentary, which
ملخص المحتوى في الصفحة رقم 10
Wireless Controller (FC-W) (Optional) This mode will allow you to control the fogger using the optional wireless controller. This consists of the transmitter and the receiver. You may control up to 4 independent fog machines, or many more if you run them simultaneously. See the below instructions on setting up your fogger to operate with the FC-W. 1. Plug the wires receiver into the fog machine 5-pin port labeled “Wireless Controller”. 2. There are 4 buttons on the wireless remote transm
ملخص المحتوى في الصفحة رقم 11
General Troubleshooting Symptom Solution(s) No Power Check mains power. Check external fuse. Check internal fuse. No fog output Check fluid level. Check remote. If using wireless, check batteries. If using wireless, check dipswitches on receiver. Breaker/Fuse keeps blowing Possible electrical short. Contact Chauvet or a Chauvet Dealer/distributor for further instruction. Low fog output Run a cleaning solution through the fog machine. Check that the fog machine is plugged into the
ملخص المحتوى في الصفحة رقم 12
5. TECHNICAL INFORMATION General Maintenance Do not allow the haze machine to become contaminated. After every 40 hours of continuous operation, use Chauvet® Fog Cleaner Quart (or a solution of 80% distilled water and 20% distilled vinegar) through the system to prevent the accumulation of particulate matter in the heating element is recommended. The recommended cleaning regimen is as follows: 1. Empty all haze liquid from the machine. 2. Add cleaning solution to tank. 3. Plug unit i
ملخص المحتوى في الصفحة رقم 13
Return Procedure Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. Package must be clearly labeled with a Return Merchandise Authorization Number (RMA #). Products returned without a RMA # will be refused. Call CHAUVET and request a RMA # prior to shipping the fixture. Be prepared to provide the model number, serial number and a brief description of the cause for the return. Be sure to properly pack fixture, any shipping damage resulting
ملخص المحتوى في الصفحة رقم 14
TECHNICAL SPECIFICATIONS WEIGHT & DIMENSIONS Length ...................................................................................................10.2 in (258 mm) Width ..................................................................................................... 9.5 in (242 mm) Height .................................................................................................... 8.9 in (225 mm) Weight ....................................................................