ملخص المحتوى في الصفحة رقم 1
CHARNWOOD
DX20i MkII
Multifuel Roomheater
Operating
and
Installation Instructions
Bishops Way, Newport, Isle Of Wight, PO3O 5WS, U.K.
Tel: (01983) 537799 Fax: (01983) 537788
ملخص المحتوى في الصفحة رقم 2
OPERATING INSTRUCTIONS FOR THE CHARNWOOD DX20i MKII GENERAL POINTS whether you are in a smoke control will also result in considerably area, then please check with your reduced outputs. The wood should be Before lighting the fire check with Local Authority. cut and split and then left to season the installer that the work and checks in a well ventilated dry place for at described in the installation least one year but preferably two Smokeless Fuels instructions have been carried out years before
ملخص المحتوى في الصفحة رقم 3
Open the main doors Open the ashpit (marked on the handle of the tool) door Close the ashpit door Close the until the tool is vertical. The grate is main doors put into the solid fuel position by moving the tool in the direction of the arrow "C" until the tool is MULTIFUEL GRATE horizontal. Airwash Control Your Charnwood is fitted with a Closed Open multifuel grate which enables solid If a mixture of wood and solid fuel, fuel, wood and peat to be burned or peat and solid fuel, is to be burnt equ
ملخص المحتوى في الصفحة رقم 4
For safety reasons, if the fire is to be using solid fuel do not go beyond the REFUELLING left unattended with the doors open 45° position as this can cause the then use a spark guard which grate to jam. complies with BS 3248. Keep the firebox well filled (the fuel If jamming does occur then the fire may be sloped up from the front should be allowed to burn for firebars), but do not allow fuel to ASH CLEARANCE approximately half an hour before spill over the top of the front fire The ashpan must
ملخص المحتوى في الصفحة رقم 5
THROAT PLATE AND CLEANING AND CHIMNEY SWEEPING FLUEWAY CLEANING MAINTENANCE The chimney should be swept at least It is important that the throat plate The appliance is finished in vitreous twice a year. In most installations it and all the appliance flueways are enamel. To clean the surfaces simply will be possible to sweep the chimney kept clean. When burning smokeless wipe over with a dry cloth. Abrasive through the appliance. fuels they should be cleaned monthly. pads and scouring cleaners mu
ملخص المحتوى في الصفحة رقم 6
emission is flueway or chimney should cause the chimney fire to go Fire Blazing Out Of blockage. For your own safety these out in which case the control should Control. must be kept clean. be kept at the minimum setting until the fire in the appliance has gone out. Check that: The chimney and flueways should Door Glass Blacks Up a) the doors are tightly closed, then be cleaned. If the chimney fire b) the thermostat knob is turned Keeping the glass clean requires a does not go out when the above
ملخص المحتوى في الصفحة رقم 7
CHARNWOOD DX20i INSTALLATION INSTRUCTIONS HEALTH AND SAFETY Sunbrite Doubles at a rate of 1.0 be fitted in accordance with the PRECAUTIONS kg/hr with the doors closed over a 4 manufacturers instructions and hourly re-fuelling interval. Building Regulations. WARNING Please take care when installing the appliance that the There is an optional add-in domestic Single wall flue pipe is suitable for requirements of the Health and Safety hot water boiler available with an connecting the appliance to th
ملخص المحتوى في الصفحة رقم 8
appliance. In some situations it may storage cylinder to BS:1566 part 1 be necessary to shield the beam or should be used in most situations, mantelpiece to protect it. unless the appliance is to be fitted in a soft water area in which case a direct hot water cylinder may be used PREPARATION OF provided that the boiler is glass lined. FIREPLACE ThisDimension IsThe All pipework in the primary circuit Minimum Level Area Required To Enable The Before fitting the appliance into an must be 28mm diame
ملخص المحتوى في الصفحة رقم 9
same side as the boiler tappings. One that the legs of the elbow are recommended mix is six volumes of of the original side firebricks is fitted different lengths to enable some vermiculite granules to one volume of on the other side, and the rear situations to be catered for by turning portland cement thoroughly mixed firebrick is discarded. The firebricks the elbow around. together. Enough water should be must be fire cemented into position, added so that no more than one or wetting the firebo
ملخص المحتوى في الصفحة رقم 10
The free inset method of installation PRE LIGHTING may be used instead of infilling. Flap Just Closed With CHECK Details are available on request. Knob Set To Minimum Before initial lighting check the THERMOSTAT following points: Before lighting the fire check the cold setting distance of the 1. The bottom grate bars must all be thermostat. fitted and should move freely and easily when the riddling mechanism With the control knob at the is operated. minimum setting the flap should be just closed
ملخص المحتوى في الصفحة رقم 11
400 150 i/d 84 260 Optional Boiler May BeFitted WithThe1" B.S.P. MaleTappings OnTheLeft Or TheRight. 620 150º 604 547 506 405 265 200 260 120 CharnwoodDX20i MkII Overall Dimensions (Dimensionsare in mm) Page 11 HV 7/96