ملخص المحتوى في الصفحة رقم 1
CHARNWOOD
COUNTRY 4
Operating
and
Installation Instructions
Bishops Way, Newport, Isle Of Wight, PO3O 5WS, U.K.
Tel: (01983) 527552 Fax: (01983) 821267
Internet: www.charnwood.com Email: charnwood@ajwells.co.uk
ملخص المحتوى في الصفحة رقم 2
CHARNWOOD COUNTRY 4 OPERATING INSTRUCTIONS Before lighting the stove check with Smokeless Fuel FITTING THE the installer that the work and checks OPTIONAL COAL KIT A wide variety of smokeless fuels are described in the Installation available, many of which are suitable Instructions have been carried out Before burning coal or smokeless fuel for use on your Country 4. Some of correctly and that the chimney has the coal kit must be fitted. This these are listed below: been swept, is sound and free
ملخص المحتوى في الصفحة رقم 3
When relighting the stove, leave the deposits than other fuels, especially if ash on the base if burning wood or the fire is run at low levels for long peat, unless it is becoming too deep, periods. It is therefore vital to clean in which case some of it may be the throat plate regularly, weekly removed. If burning solid fuel clear cleaning is recommended. the grate and empty the ashpan Never fully close the Airwash control before relighting. when burning coal. CONTROLLING THE RUNNING THE FIRE F
ملخص المحتوى في الصفحة رقم 4
to the desired setting. CHIMNEY SWEEPING Door Glass Blacks Up The chimney should be swept at least Differences in chimney draughts CLEANING AND twice a year. Where the top outlet or mean that the best settings of the air MAINTENANCE vertical rear flue connector is used it controls will vary for different will generally be possible to sweep installations. A certain amount of The stove is finished with a high the chimney through the appliance. experimentation may be required, temperature paint whi
ملخص المحتوى في الصفحة رقم 5
The most common cause of fume should cause the chimney fire to go Fume Emission. emission is flueway or chimney out in which case the controls should blockage. For your own safety these be kept closed until the stove has Warning Note: must be kept clean. gone out. The chimney and flueways Properly installed and operated this should then be cleaned. If the appliance will not emit fumes. chimney fire does not go out when Occasional fume from de-ashing Fire blazing out of the above action is taken
ملخص المحتوى في الصفحة رقم 6
CHARNWOOD COUNTRY 4 INSTALLATION INSTRUCTIONS The internal dimensions of the a gap behind the stove of at least HEALTH AND SAFETY chimney should preferably be 175 75mm for access and to allow air to PRECAUTIONS mm (7 inches) or 200mm (8 inches) enter the airwash inlets. The either square or round and MUST positioning of the stove and the size Please take care when installing the NOT BE LESS THAN 125 mm (5 of the hearth are governed by stove that the requirements of the INCHES). building regulati
ملخص المحتوى في الصفحة رقم 7
Also check all joints and seals. On kept to a minimum and should not be completion of the installation and more than 125mm (5 inches) long. commissioning please leave the The sealing face of the flue collar operating instructions with the must be coated with fire cement customer and advise them on the use before fixing to the body of the stove of the appliance. using the two screws provided. The blanking plate must be removed, sealed with fire cement and refitted, care being taken to ensure that
ملخص المحتوى في الصفحة رقم 8
Overall Dimensions (All dimensions are in mm) Page 8 Country 4 7/98 b