Model No. 0340 -- OWNER’S MANUAL
HIGH WEARABILITY TYPE V
USER ASSISTED INFLATABLE BELT
PERSONAL FLOTATION DEVICE
ADULT UNIVERSAL – FOR PERSONS OVER 80 POUNDS
Deflated Inflated
I. APPROVAL CONDITIONS and CARRIAGE REQUIREMENTS
This inflatable belt is approved by the U S Coast Guard as a Type
V User Assisted Personal Flotation Device (PFD). It is APPROVED
ONLY WHEN WORN for use as a Flotation Aid, Type III PFD for
recreational use on calm inland waters. It is not approv
ملخص المحتوى في الصفحة رقم 2
SPECIFICATIONS Chest size: 30-52 inches Weight range: over 80 pounds Age Range: 16 years and older Buoyancy (minimum): 15.5 pounds after CO inflation 22.5 2 pounds after full inflation. (See Donning and Inflation instructions pages 7 & 8.) Inflation System: Manual Inflation Mechanism (located on front of chamber) Oral Tube (located on front of chamber) CO Cylinder: 16 Gram, 3/8” thread. 2 ** USE REPLACEMENT KIT NO. 0925 ** GENERAL ARRANGEMENT Revised: 2006-05-08 2
ملخص المحتوى في الصفحة رقم 3
II. CONDITIONS FOR TYPE V APPROVAL Conditional approvals are granted by the Coast Guard for PFDs that: 1. Do not meet all the requirements for approval under the Type I through IV categories, but offer other significant safety features, or 2. Have features or uses not found in Types I through IV PFDs that require special user knowledge. The conditions let the user overcome design traits that would otherwise prevent approval. Wearing a PFD is one of the most important things you can do to help yo
ملخص المحتوى في الصفحة رقم 4
MANDATORY CARRIAGE REQUIREMENTS Federal Regulations in 33 CFR 175-1993 require you to carry Coast Guard approved personal flotation devices (PFDs) legibly marked with the Coast Guard approval number, which are in good and serviceable condition, and are the correct size for each person on board. To be considered serviceable, this PFD shall not exhibit deterioration that could diminish its performance such as broken or deformed hardware, detached webbing, rotted structural components, air leaks or
ملخص المحتوى في الصفحة رقم 5
2. Examine the inflation mechanism status indicators. The indicator will tell you if the inflation mechanism is properly ARMED/REARMED and ready for activation. If the indicator shows RED, the mechanism is not ready to fire, and you must rearm the mechanism to set the indicator to GREEN. Refer to rearming instructions on Pages 11 and 12, and on the PFD chamber. 3. Examine Your CO Cylinder 2 The CO cylinder contains the gas charge that will inflate your 2 PFD when the inflation mechanism is fire
ملخص المحتوى في الصفحة رقم 6
OTHER USE GUIDE LINES - STUDY this manual and practice using your belt to become thoroughly familiar with its features and operation. Your inflatable PFD will not provide buoyancy until you inflate it. See Pages 17 and 18 for testing your PFD. ALWAYS re-arm the CO inflation system after each discharge. 2 The CO cylinder is good for only one inflation and then must be 2 replaced. Use ONLY genuine Stearns replacement kits for rearming your PFD. See Pages 11 and 12 for rearming instructions. NEVER
ملخص المحتوى في الصفحة رقم 7
DONNING and INFLATION INSTRUCTIONS After completing the pre-donning check, follow these instructions to don, inflate and adjust the PFD for maximum performance. 1. Buckle the deflated belt around your waist and adjust to snug fit by pulling on the free end of the belt. Secure the excess strap by tucking it under the belt. Always position the belt with the center window in front. The Velcro® opening should be on the bottom. The “Jerk to Inflate” lanyard should be hanging downward. 2. Pull do
ملخص المحتوى في الصفحة رقم 8
DONNING INSTRUCTIONS CONTINUED - 4. Adjust the length of the neck strap for desired comfort and head support. Pull down on the adjustment strap to tighten, or lift up the plastic slide to loosen. 5. After CO inflation, the 2 performance of the PFD may be satisfactory without further action. However, higher buoyancy is easily available through second stage inflation. Using the oral inflation tube, you may top off buoyancy to the desired level. 8
ملخص المحتوى في الصفحة رقم 9
MAXIMIZING PERFORMANCE Why should someone do this? It is important to learn how to use this PFD in the water. Try your PFD in the water before attempting to use it in deep water or in an emergency to find out what position and adjustments provide the best support for you. It is important, especially in cold water and wave conditions, to get your head out of the water as much as possible. Doing this will reduce the amount of heat loss through your head, (see "Hypothermia", Pages 19 and 20), im
ملخص المحتوى في الصفحة رقم 10
DEFLATION INSTRUCTIONS Deflating may be accomplished by inserting the deflation tool located on the dust cap into the end of the oral inflation tube while gently squeezing the inflation chamber. Reposition the dust cap over the end of the inflation tube after deflating to help protect the valve inside. DO NOT TWIST OR WRING INFLATABLE CHAMBER TO DEFLATE. If for any reason the oral valve remains open, depress it several times. If it does not release, discontinue use of this PFD and return to Stea
ملخص المحتوى في الصفحة رقم 11
REARMING INSTRUCTIONS STEP 1 Unscrew used CO cylinder in a 2 counterclockwise direction and immediately discard. Do not insert new cylinder at this time. To avoid confusion later in the rearming process, we suggest you throw away the old CO cylinder now. 2 STEP 2 Close manual inflator arm within inflator body and carefully insert a new green indicator tab so that it fully covers the red semi-circle on the body. STEP 3 Look into threaded cylinder receiver and view the gasket. If worn, contact Ste
ملخص المحتوى في الصفحة رقم 12
REARMING INSTRUCTIONS (cont.) Step 4 Inspect the face of the new cylinder. Be sure it is smooth and has no holes or scratches. There is a gross weight on the cylinder. If you have any questions about cylinder integrity, weigh the cylinder on a small scale, such as a postage scale. Compare the weight printed on the cylinder to the actual weight. If they do not match, get another cylinder. STEP 5 Screw new cylinder in a clockwise direction firmly into the inflator. Do not over-tighten, but ensure
ملخص المحتوى في الصفحة رقم 13
REPACKING INSTRUCTIONS Always dry out, deflate the PFD and rearm the inflation mechanism. Follow REARMING instructions prior to REPACKAGING. 13
ملخص المحتوى في الصفحة رقم 14
IV. IS YOUR PFD IN GOOD AND SERVICEABLE CONDITION? Check your PFD between outings to be sure that it is properly armed; that it is free of rips, tears or holes; that all seams are securely sewn; and that the fabric, straps and hardware are still strong. Check to be sure your cylinder is screwed in tight. Inspect the inflatable portion of the PFD in accordance with Care and Maintenance Instructions. V. CARE AND MAINTENANCE INSTRUCTIONS GENERAL PRODUCT LIFE EXPECTANCY The relia
ملخص المحتوى في الصفحة رقم 15
2. Oral Inflation Leak Test - This test should be performed every two months and at the start of each season. Inflate buoyancy chamber using the oral inflation valve and leave to rest for 16 hours. When buoyancy chamber remains firm and full of air there is no leakage and chamber is operational. If the chamber deflates during this leak test, it is no longer in operational condition and should not be used. Some types of leaks can be repaired by a certified Stearns Repair Facility, while other
ملخص المحتوى في الصفحة رقم 16
STORAGE • Store in clean, cool, dry area. • Do not store in direct sunlight. REPAIR If you have any question about the condition or integrity of this product call 1-800-STEARNS (1-800-783-2767). A damaged device must be repaired by certified Stearns Repair Facility or discarded. SERVICING Stearns strongly recommends that this device be inspected at least every 24 months by a certified Stearns Repair Facility or STEARNS Inc. Call 1-800-STEARNS (1-800-783-2767) for your nearest certified Stearns
ملخص المحتوى في الصفحة رقم 17
VII. HOW AND WHY TO TEST YOUR PFD? Inflate your PFD and try it out in the water to: • Make sure it floats you: Comfortably (When worn properly) Adequately for expected wave conditions (Body shapes/densities affect performance) • Make sure it works: A flow of bubbles should not appear (See Section V for leak tests) It should inflate quick and easily • Learn how it works by: Activating the CO inflation system 2 Rearming the CO inflation system 2 Using the Oral inflator tube HOW DO YOU TEST YOUR PF
ملخص المحتوى في الصفحة رقم 18
HOW DO YOU TEST YOUR PFD USING THE ORAL INFLATOR? 1. To test your inflatable PFD, you will not need any spare parts. 2. Remove the CO cylinder to prevent inadvertent activation of 2 the manual inflation which could potentially damage the PFD. Inspect the threaded end to confirm it’s un-used. 3. Put on the PFD. 4. Get into shallow water, just deep enough that you can stand with head above the surface. 5. If you are a weak or non-swimmer, inflate the PFD partially so that you are supported well en
ملخص المحتوى في الصفحة رقم 19
VIII. WEAR YOUR PFD In approximately 80 percent of all boating fatalities, the victims were not wearing a PFD. Most fatal accidents happen on calm sunny days. This inflatable PFD is much more comfortable to wear than other PFD types. Get into the habit of wearing this PFD. Non-swimmers and children especially should wear a hybrid or non-inflatable PFD at all times when on or near the water. IX. HYPOTHERMIA Prolonged exposure to cold water causes a condition known as hypothermia — a substantial l
ملخص المحتوى في الصفحة رقم 20
Some Points to Remember About Hypothermia Protection: 1. Always wear your PFD. Even if you become incapacitated due to hypothermia, the PFD will keep you afloat and greatly improve your chances of rescue. 2. Do not attempt to swim unless it is to reach a nearby craft, fellow survivor, or a floating object on which you can lean or climb. Swimming increases the rate of body heat loss. In cold water, drown-proofing methods that require putting your head in the water are not recommended. Keep your h