ملخص المحتوى في الصفحة رقم 1
MD1250
tactical inflatable SiDe Pouch lP
ملخص المحتوى في الصفحة رقم 2
Do not ReMo Ve PRioR to S ale Warning: This document is for the use of licensed users only. No part of this document may be reproduced, transmitted, or transcribed in any form or by any means without the express permission of Mustang Survival Corp. While every effort possible has been made to ensure technical accuracy, information within this document is subject to change without notice. i Tactical Inflatable Side Pouch LP Owners Manual
ملخص المحتوى في الصفحة رقم 3
content S Introduction ...................................................................................................1 Product Familiarization and Readiness .......................................................2 Readiness Checklist .........................................................................3 Wearing the LP ..............................................................................................3 Using an LE Belt ..........................................................
ملخص المحتوى في الصفحة رقم 4
intRoDuction This manual provides instructions and guidelines for safely using and maintaining Mustang Survival MD1250 Tactical Inflatable Side Pouch Life Preservers (LPs). The MD1250 LP provides flotation capability with minimum bulk or interference using separate, independently operated left and right LPs. The MD1250 LP has been designed specifically for easy integration with law enforcement (LE) belts, and body armor and tactical vests, including integrated Pouch Attachment Ladder System
ملخص المحتوى في الصفحة رقم 5
PRoDuct f aMiliaRization anD ReaDine SS The MD1250 Tactical Inflatable Side Pouch LPs are used in right/left pairs, and can be attached to an LE belt, or integrated PALS webbing and MOLLE vest. Right-hand LPs have the letter R on the attachment webbing straps (Figure 2); left-hand LPs have the letter L. Figure 1 shows the front of a right-hand LP, locating the upper zipper (1), the elastic storage pocket (2), the automatic/manual conversion cap Figure 1 Figure 2 and lanyard (3) stowed in t
ملخص المحتوى في الصفحة رقم 6
Readiness checklist if the inflator expiry date has passed, Mustang Survival recommends water testing the MD1250 lP to become familiar with its in-water functionality. When all boxes are checked, the LP is ready for use: F Status indicator is green. F Inflator expiry date has not passed. F Fabric, straps, and hardware are free from defects. F The beaded manual inflation handle is fastened. F No rips, tears, or holes, and all seams are securely sewn. F All zippers, Velcro® tabs, and buckles are
ملخص المحتوى في الصفحة رقم 7
2. Release the attachment webbing straps on the back of the LP by pulling up on each strap just below the bottom edge of the pull-the-dot snap. 3. Feed the attachment webbing straps on the back of the LP through the PALS webbing. 4. Reattach the pull-the-dot snaps by pushing down on the top edge of the snap opposite the dot. inflating the lP WaRning: When using the MD1250 lP in temperatures below freezing, fully discharging the co cylinder may not provide adequate inflation. to 2 compensate
ملخص المحتوى في الصفحة رقم 8
4. Release the mouthpiece, and turn the locking ring counterclockwise to close the inflator valve and lock the mouthpiece in place. Donning the inflateD lP Figure 6 Once the LPs have been inflated through manual, automatic, or oral inflation, tuck the inflated cells underneath each arm (Figure 6). Attach the left and right cells together using the Velcro® straps located at the front of each lobe. conVeR ting the lP note: a fully armed MD1250 lP with an Ma7219 auto/manual conversion cap is r
ملخص المحتوى في الصفحة رقم 9
4. Release the mouthpiece, and turn the locking ring counterclockwise to close the inflator valve and lock the mouthpiece in place. 5. Complete repacking of the LP – see Repacking the LP. Re-aRMing the lP caution: t he MD 1250 lP must be deflated before being re-armed. 1. Open the zippers completely, wipe off any water, and place the LP on a smooth, flat surface with the hydrostatic inflator facing the user. 2. Hold the CO cylinder through the fabric 2 and insert the metal key between the b
ملخص المحتوى في الصفحة رقم 10
12. Ensure that the status indicator on the replacement inflator cap is green, the lanyard for the beaded manual inflation handle is present, and the locking ring is locked. 13. To test for leakage, inflate the LP using the oral inflator tube – see Inflating the LP. To avoid damage to the LP do not exceed 2 psi. After two hours there should be no noticeable drop in pressure in the LP. RePacking the lP note: a fter each field-use inflation, the MD1250 lPs must be rearmed, leak tested, and fu
ملخص المحتوى في الصفحة رقم 11
Figure 14 Figure 15 Figure 16 INFLATED DEFLATED VACUUMED 10. Ensure the bladder fabric is wrapped tightly around the CO cylinder 2 and the hydrostatic inflator (Figures 14–16). 11. Remove the vacuum fitting from the oral inflation tube. 12. Detach the automatic/manual conversion cap (MA7219) from the hydrostatic inflator. The pressure within the bladder should increase as some gas enters through the water inlet valve. If the volume of gas contained within the bladder does not noticeably inc
ملخص المحتوى في الصفحة رقم 12
final Packing 1. Ensure the opening in the cover fabric is secured around the hydrostatic inflator. The water inlet valve should be easily accessible. 2. Secure the beaded handle to the LP cover using the snaps at the base of the unit. Maintaining the lP Before each use, review the Readiness Checklist – see Product Familiarization and Readiness. note: a fter each inflation, re-arm the MD1250 lP as soon as possible. After each use, deflate, re-arm, and repack the LP – see: • Deflating the LP
ملخص المحتوى في الصفحة رقم 13
• Visually inspect the expiry date on the hydrostatic Figure 20 inflator. If the expiry date has passed, replace the inflator – see Re-arming the LP. testing for l eaks Perform this test every 180 days, or more frequently if the LP is exposed to extreme conditions. 1. Orally inflate the LP until it is firm to the touch, and let it stand for two hours – see Inflating the LP. A leaking LP will not maintain its firmness. 2. If the LP is leaking, take it to a Mustang Survival dealer for evalu
ملخص المحتوى في الصفحة رقم 14
testing the a utomatic inflator note: a left/right pair of fully armed MD1250 lPs and two Ma7214-10 re-arm kits are required for this test. 1. Attach the LPs to the left and right sides (see Wearing the LP). 2. Enter water of an appropriate depth to keep the head above the surface. 3. When submerged in water, the hydrostatic manual/automatic inflator releases CO into the inflation cell, inflating the LP. 2 4. Don the inflated LP (see Donning the LP). 5. Ensure the LPs float the user just slig
ملخص المحتوى في الصفحة رقم 15
a cce SSoRie S MA7214-10 Re-Arm Kit: 33 gram CO replacement cylinder and inflator 2 cap (two kits required for each pair of MD1250 LPs) MA7219 Auto/Manual Conversion Cap gloSS a Ry Term Definition LP Life preserver MOLLE Modular Lightweight Load-carrying Equipment PALS Pouch Attachment Ladder System psi Pounds per square inch 12 Tactical Inflatable Side Pouch LP Owners Manual
ملخص المحتوى في الصفحة رقم 16
Do not ReMo Ve PRioR to S ale For 40 years Mustang Survival has been committed to providing life support solutions. Through constant innovation and the application of new technologies, Mustang is the leading supplier of quality flotation and hypothermia protection products to the most demanding users – from fishermen, sailors and power boaters to the Coast Guard, fighter pilots and even NASA astronauts. www.mustangsurvival.com E-MAIL custserv@mustangsurvival.com TOLL FREE 1.800.526.0532