ملخص المحتوى في الصفحة رقم 1
Y1-03-0229D
ملخص المحتوى في الصفحة رقم 2
About Cobham Life Support, ACR Products Cobham Life Support, ACR Products, www.acrelectronics.com, designs and manufactures a complete line of safety and survival products including EPIRBs, PLBs, AIS, SARTs, Strobe Lights, Life Jacket Lights, Search Lights and safety accessories. The quality systems of this facility have been registered by UL to the ISO 9001:2000 Series Standards. Recognized as the world leader in safety and survival technologies, ACR has provided safety equipment
ملخص المحتوى في الصفحة رقم 3
Table of Contents SECTION1 - PRODUCT DESCRIPTION _________________________ 3 SECTION 2- SEARCHLIGHT MOUNTING _______________________ 4 SECTION 3 - REMOTE CONTROL SYSTEM _____________________ 5 SECTION 4 - URP-102 POINT PAD™ __________________________ 5 SECTION 5 - URC-300 MASTER CONTROLLER __________________ 7 SECTION 6 - POINT PAD™ OPERATION _______________________ 9 APPENDIX A - SPECIFICATIONS ____________________________ 11 APPENDIX B - KIT COMPONENTS __________________________
ملخص المحتوى في الصفحة رقم 4
SECTION1 - PRODUCT DESCRIPTION Introduction The RCL-300A was specially designed for mariners who require a high intensity remote controlled searchlight that can stand up to the tough marine environment. The sleek design and modern construction of the searchlight body makes it attractive for recreational and commercial vessels. The searchlight is totally enclosed and is made of rugged aluminum alloy. It is gasketed and finished to be resistant to the weather. The RCL-300A searchlig
ملخص المحتوى في الصفحة رقم 5
Figure 1- RCL-300A Components SECTION 2- SEARCHLIGHT MOUNTING Make sure the area is clean and dry. The searchlight can be mounted where desired, using appropriate length 5/16” diameter stainless steel fasteners. One set is provided in the mounting kit and four (4) nylon shoulder washers. The nylon washers prevent a galvanic reaction between the mounting hardware and the base of the searchlight. Be sure these washers have been inserted in the base mounting holes and that the mo
ملخص المحتوى في الصفحة رقم 6
Self Park Feature The RCL-300A has a Self-Park feature. The Self Park function will automatically return the light to a specific position when turned off. When mounting the light, determine in advance the direction that the light should face when it is turned off. Align the red marker on the base 180° opposite of the final facing direction. To activate the Self-Park feature, press the “Speed” button on the UPR- 102 Point Pad™ for more than five (5) seconds. Figure 2- URC-300 Maste
ملخص المحتوى في الصفحة رقم 7
Mounting Both the surface mount and the flush mount options require access to the backside of the mounting location. Verify that there are not any obstructions behind the area where the switch is to be located, e.g., bulkheads, wires, plumbing or hardware. Check that the coax cable from the Master Controller can be routed to this location. Generally, the Point Pad™ should be mounted in a protected area. Surface Mount Install the surface mount Point Pad™ by drilling three (3) holes in
ملخص المحتوى في الصفحة رقم 8
SECTION 5 - URC-300 MASTER CONTROLLER Mounting The Master Controller can be mounted in any position near the searchlight that is protected from the weather. Check in advance that the coax cable from the Point Pad and the wiring harness from the searchlight can be routed to this location. Mount the Master Controller with the wires and coax facing down. Use an appropriate fastener for your mounting location. Use a sealant in fastener holes to prevent moisture intrusion. General wiring s
ملخص المحتوى في الصفحة رقم 9
Wiring to the searchlight The RCL-300A searchlight is supplied with a 15-foot integral wire harness. If you must lengthen the wire harness, use heavy duty wire to minimize the voltage drop. This is especially important for the WHITE 12 AWG lamp power, BLACK 12 AWG lamp ground, ORANGE power wire and BLUE ground wires. Following the wiring scheme above and Appendix C. use the supplied butt connectors to connect the Master Controller to the searchlight. Wiring the Point Pad™ The RG-5
ملخص المحتوى في الصفحة رقم 10
The URC-300 Master Controller has a searchlight motor time-out feature. If a Point Pad™ rotation switch (right or left) is continually engaged for more than 50 seconds, the Master Controller will interrupt the operation until the Point Pad switch is disengaged. This feature will save the searchlight motor from burnout due to accidental activation. The elevation motor has similar features which will timeout in approximately 20 seconds. XRCiZ™ feature The URC-300 Master Controller has t
ملخص المحتوى في الصفحة رقم 11
Press the Up or Down arrows to raise or lower the searchlight beam. To activate the XRCiZ™ feature, press and hold the ON/OFF button for more than 5 seconds. The green LED ind9cates that the XRCiZ™ feature is enabled. To deactivate the XRCiZ™ feature, press and hold the ON/OFF button for more than 5 seconds. The red LED ind9cates that the XRCiZ™ feature is disabled. An LED blinking red/green indicates that then XRCiZ™ feature is now “exercising” the searchlight. To activate
ملخص المحتوى في الصفحة رقم 12
APPENDIX A - SPECIFICATIONS Characteristics Specification Size 12 X 13 X 9.3 in (31 X 33 X 23.5 cm) Weight 31 lb (14.06 kg) Material Cast aluminum, tempered glass Input voltage* 12V- 24V Amp draw Startup 25A @ 12V, Running 8A @ 12V Color White Operation Remote controlled Point Pad™ Beam spread 6° Elevation angle 12° up, 38° down Rotation 360° continuous Rotation speed Fast 30° per second, Slow 12° per second 7° per second Elevation speed - Twin 35W metal halide lamps Lamp -
ملخص المحتوى في الصفحة رقم 13
APPENDIX B - KIT COMPONENTS Product No. 1930.3 - RCL-100D 12 V Searchlight Installation Kit includes: Description Quantity ACR Part Number Searchlight, RCL-300A 1 A3-06-2558 Point Pad™, URP-102 with surface mount 1 A3-06-2230 case URC-300 Master Controller unit 1 A3-06-2231-1 A1-18-1875-2 Case, flush mount 1 Gasket, surface mount 1 A1-25-0140-1 Gasket, flush mount 1 A1-25-0140-2 U Clamp 2 A1-17-1366 Nuts, nylon- lock 2 A1-05-0776 Washers 2 A1-05-0777 Cable, coaxial 30ft A2-07-
ملخص المحتوى في الصفحة رقم 14
APPENDIX C - WIRING DIAGRAM Y1-03-0232D 13
ملخص المحتوى في الصفحة رقم 15
APPENDIX D - WARRANTY, USEFUL LIFE POLICY, NOTICES Limited Warranty This product is warranted against factory defects in material and workmanship for a period of 1 (one) year* from date of purchase or receipt as a gift. During the warranty period ACR Electronics, Inc. will repair or, at its option, replace the unit at no cost to you for labor, materials and return transportation from ACR. For further assistance, please contact our Technical Service Department at ACR Electronics, Inc., 5
ملخص المحتوى في الصفحة رقم 16
EC DECLARATION OF CONFORMITY ACR Electronics, Inc. hereby declares that the following product is in conformity with Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on Electromagnetic Compatibility (EMC Directive). In accordance with the Directive, the product will be marked with the CE conformity marking as follows: Product: Searchlight Model: RCL-300A Regulations and EN 60945: 2002: Emissions: Standards: CISPR 16-1:1999 (Conduc