ملخص المحتوى في الصفحة رقم 1
R
Room Air Conditioner
INSTALLATION AND OPERATING INSTRUCTIONS
Model: CW-XC80HU
Please read these operating instructions thoroughly
before using your air conditioner and keep for future reference.
For U.S customers :
For assistance, please call : 1-800-211-PANA(7262) or
Register your product at : http://www.panasonic.com/register
CW382820391J
F
hr
F FA AN N
S SP PE EE ED D
ECONOMY FAN COOL
DRY
TIMER MODE OFF/ON
T TE EM MP P OPERATION
ملخص المحتوى في الصفحة رقم 2
Safety Precautions Safety Precautions .............3 FOR YOUR RECORDS Staple your receipt to this page in case you need it later. Write down the model and serial numbers here: Model # Serial # You can find them on a label on the side of each unit. Dealer's Name Date Purchased About the Controls on the Air Conditioner Controls..............................5 READ THIS MANUAL Remote Controller ..............6 Ventilation ..........................7 Inside you will find many helpful hints on how to
ملخص المحتوى في الصفحة رقم 3
Safety Precautions Safety Precautions To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instruction will cause harm or damage. The seriousness is classified by the following indications. WARNING : This symbol indicates the possibility of death or serious injury. This symbol indicates the possibility of injury or damage to CAUTION : property only. Meanings of symbols used in this manual are a
ملخص المحتوى في الصفحة رقم 4
When the air filter is to be Do not clean the air Ventilate well when used conditioner with water. removed, do not touch the together with a stove, etc. metal parts of the unit. • It may cause an injury. • An oxygen shortage may occur. • Water may enter the unit and degrade the insulation. It may cause an electric shock. When the unit is to be Do not put a pet or house Do not use for special cleaned, switch off, and turn plant where it will be exposed purposes. off the breaker. to direct air flo
ملخص المحتوى في الصفحة رقم 5
About the Controls on the Air Conditioner About the Controls on the Air Conditioner Controls Model : CW-XC80HU F 6 hr FA FAN N 4 SPEED SPEED ECONOMY FAN COOL DRY TIMER MODE OFF/ON 1 TEMP TEMP OPERATION 3 2 5 FAN SPEED OPERATION • Every time you push this button it is set as • To turn the air conditioner ON, push the follows. {High(F3) Low(F1) Med(F2) OFF/ON button. High(F3)...}. To turn the air conditioner OFF, push the button again. TEMPERATURE SETTING • This button takes priority over an
ملخص المحتوى في الصفحة رقم 6
Remote controller Precaution: The Remote Controller will not function properly if strong light strikes the sensor window of the air conditioner or if there are obstacles between the Remote Controller and the air conditioner. Model: CW-XC80HU OPERATION 1 TEMP 5 TIMER 3 MODE FAN SPEED 2 4 OPERATION - STARTING OPERATION • Every time you push this button, when the air • To turn the air conditioner ON, push the button. conditioner is not operating, timer is set as follows. To turn the air conditione
ملخص المحتوى في الصفحة رقم 7
About the Controls on the Air Conditioner F hr TIMER OPERATION TEMP/TIMER SET OFF/ON CA SE NT C/EL COOL FAN MODE AIR SWING ECONOMY H M IG EH D FAN SPEED LOW W Remir oe tel C e os ns trol Additional controls and important information. Ventilation The ventilation lever must be in the CLOSE position in order to maintain the best cooling conditions. When fresh air is necessary in the room, set the ventilation lever to the OPEN position. The damper is opened and room air is drawn out. CLOSE VENT OPE
ملخص المحتوى في الصفحة رقم 8
Care and Maintenance TURN THE AIR CONDITIONER OFF AND REMOVE THE PLUG FROM THE POWER OUTLET. Air Filter Cleaning The air filter behind the front grille should be checked and cleaned at least once every 2 weeks or more often if necessary. TO REMOVE: 1. Open the inlet grille upward by pulling out the bottom of the inlet grille or downward by pulling out the top of the inlet grille. 2. Using the tab, pull up slightly on the filter to release it and pull it down or up. 3. Clean the filter with warm
ملخص المحتوى في الصفحة رقم 9
Features and Installation F hr F FA AN N S SP PE EE ED D ECONOMY FAN COOL DRY TIMER MODE OFF/ON T TE EM MP P OPERATION Features Learning parts name prior to installation will help you understand the installation procedure. Features VERTICAL AIR DEFLECTOR (HORIZONTAL LOUVER) HORIZONTAL AIR DEFLECTOR (VERTICAL LOUVER) AIR DISCHARGE CABINET FRONT GRILLE AIR FILTER AIR INTAKE (INLET GRILLE) BRACE COMPRESSOR CONDENSER EVAPORATOR BASE PAN CONTROL BOARD REMOTE CONTROLLER POWER CORD 9 F hr S SP PF F E E
ملخص المحتوى في الصفحة رقم 10
INSTALLATION How to Install the Unit 1. To prevent vibration and noise, make sure the unit is installed securely and firmly Fence 2. Install the unit where the sunlight does not Awning shine directly on the unit. Cooled air Heat 3. The outside of the cabinet must extend radiation outward for at least 28cm (11") and there should be no obstacles, such as a fence or wall, within 50.8cm (20") from the back of the cabinet because it will prevent heat 1 About 12.7mm ( /2") 76.2cm (30")~ radiation of
ملخص المحتوى في الصفحة رقم 11
Features and Installation Installation Kit Contents NO. NAME OF PARTS Q'TY 2 3 4 1 1 FRAME CURTAIN 2 2 SILL SUPPORT 2 3 BOLT 2 4 NUT 2 5 SCREW(TYPE A) (10mm (25/64")) 16 8 11 9 5 6 7 D5.1mm(3/16")/16mm(5/8") 6 SCREW(TYPE B) 3 D4.1mm(5/32")/16mm(5/8") 7 SCREW(TYPE C) 5 8 FOAM-STRIP 1 10 9 FOAM-PE (466mm x 10mm x 2mm) 1 10 WINDOW LOCKING BRACKET 1 11 FOAM-PE (920mm x 30mm x 2mm) 1 12 DRAIN PIPE 1 12 Top retainer bar is in the product package. Suggested Tool Requirements SCREWDRIVER(+, -), RULER,
ملخص المحتوى في الصفحة رقم 12
Cabinet Installation 1. Open the window. Mark a line on center of the window sill (or desired air conditioner location). Carefully place the cabinet on the Upper Guide window sill and align the center mark Window sill on the bottom front with the center Front Angle Fig. 1 line marked in the window sill. (See Fig.1) Window Sash Upper guide 2. Pull the bottom window sash down Foam-pe 11 behind the upper guide until it meets.(See Fig.2) Cabinet 1 Frame Curtain 9 NOTE: Foam-pe Fig. 2 • Do not pull t
ملخص المحتوى في الصفحة رقم 13
Features and Installation 9. Attach each Frame curtain to the window sash using screws (Type C). (See Fig. 6) Type C 7 CAUTION: DO NOT DRILL A HOLE IN THE BOTTOM PAN. The unit is designed to operate 1 Fig. 6 with approximately 12.7mm ( /2") of water in bottom pan. 10. Slide the unit into the cabinet. (See Fig. 7) CAUTION: For security purposes, reinstall screws at cabinet's sides. Power cord Screw Fig. 7 Screw 8 Foam-Strip 11. Cut the foam-strip to the proper length and insert between the upper
ملخص المحتوى في الصفحة رقم 14
Electrical Data Line Cord Plug Use Wall Receptacle Power Supply Do not under any circumstances cut Use 15 AMP, time or remove the grounding prong delay fuse or circuit from the plug. breaker. Power supply cord with Standard 125V, 3-wire grounding 3-prong grounding plug receptacle rated 15A, 125V AC USE OF EXTENSION CORDS Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish to use an extension cord, use a CSA certified/UL-listed 3-wir
ملخص المحتوى في الصفحة رقم 15
Features and Installation Electrical Safety Because of potential safety hazards, we strongly IMPORTANT discourage the use of an adapter plug. However, if (PLEASE READ CAREFULLY) you wish to use an adapter, a TEMPORARY CONNECTION may be made. Use UL-listed adapter, available from most local hardware stores FOR THE USER'S PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED (Fig. 13). The large slot in the adapter must be aligned with the large slot in the receptacle to assure a proper polari
ملخص المحتوى في الصفحة رقم 16
Before you call for service... Troubleshooting Tips save time and money! Review the chart below first and you may not need to call for service. Normal Operation • You may hear a pinging noise caused by water being picked up and thrown against the condenser on rainy days or when the humidity is high. This design feature helps remove moisture and improve efficiency. • You may hear the relay click when the compressor cycles on and off. • Water will collect in the base pan during high humidity or on
ملخص المحتوى في الصفحة رقم 17
MEMO 17
ملخص المحتوى في الصفحة رقم 18
Precauciones Importantes de PARA SU INFORMACION Seguridad Precauciones Importantes Escriba aquí los números de serie y modelo de las de seguridad ....................19 unidades exterior e interior: Nº de Modelo Nº Serie Los números figuran en una etiqueta en el lateral de cada unidad. Distribuidor Fecha de compra Instrucciones de Funcionamiento LEA ESTE MANUAL Controles...........................21 Control remoto...................22 • Aquí encontrará numerosas sugerencias sobre cómo Ventilac
ملخص المحتوى في الصفحة رقم 19
Precauciones Importantes de seguridad Precauciones Importantes de Seguridad Para prevenir tanto lesiones al usuario u otras personas como daños materiales, es preciso seguir estas instrucciones. El manejo incorrecto debido a la inobservancia de estas instrucciones puede causar lesiones o daños cuya gravedad está clasificada en las siguientes indicaciones. ADVERTENCIA Este símbolo indica la posibilidad de lesiones mortales o graves. Este símbolo indica la posibilidad de lesiones o daños PRECAUC
ملخص المحتوى في الصفحة رقم 20
PRECAUCION Cuando se vaya a quitar el No limpie el acondicionador Ventile bien cuando utilice el filtro de aire no toque las de aire con agua. acondicionador junto con partes metálicas de la unidad una estufa, etc. interior. • Esto podría causar heridas. • El agua podría entrar en la • En este caso tal vez se produzca unidad y degradar el aislamiento. una falta de oxígeno. También podría causar una sacudida eléctrica. Cuando limpie la unidad, NO ponga un animal doméstico No lo utilice para propó