ملخص المحتوى في الصفحة رقم 1
Instruction
ESPAÑOL: PÁGINA 29
FRANÇAIS: PAGE 57
manual
Model
Generator
H1000IS
IMPORTANT
Please make certain that the person who is
To learn more about Porter-Cable
visit our website at: to use this equipment carefully reads and
understands these instructions before
http://www.porter-cable.com
starting operations.
The Model and Serial No. plate is located on the frame.
Record these numbers in the spaces below and retain for
future reference.
Model No.
Type
Serial No.
Copyright © 2003 Porter-
ملخص المحتوى في الصفحة رقم 2
SAFETY GUIDELINES / DEFINITIONS This manual contains information that is important for you to know and understand. This infor- mation relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these sections. indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. indicates a potentially hazardous situation which, if not avoid
ملخص المحتوى في الصفحة رقم 3
RISK OF ELECTROCUTION AND FIRE (Continued) HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN Attempting to connect to the in- To connect to a structure's electri- Attempting to coming utility service could result cal system in a safe manner, connect generator in electrocution. always have a Double-Throw directly to the Restoration of electrical service Transfer Switch installed by a electrical system while the generator is connected qualified electrician and in compli- of any building to the incoming uti
ملخص المحتوى في الصفحة رقم 4
RISK OF ELECTROCUTION AND FIRE (Continued) HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN Operation of unit Do not operate generator with Attempting to use the unit when damaged, mechanical or electrical when it has been damaged, or or with guards or problem. Have unit repaired by when it is not functioning panels removed. an Authorized Service Center. normally could result in fire or electrocution. Removal of guarding could Do not operate generator with expose electrically charged protective guarding
ملخص المحتوى في الصفحة رقم 5
RISK OF FIRE (Continued) HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN Overfilling the fuel Use care in filling the tank to Spilled fuel and its vapors can tank – fuel avoid spilling fuel. Make sure become ignited from hot spillage. fuel cap is secured tightly and surfaces or sparks. check engine for fuel leaks before starting engine. Move generator away from refueling area or any spillage before starting engine. Allow for fuel expansion. Keep maximum fuel level ¼ inch below the tip of the fuel ta
ملخص المحتوى في الصفحة رقم 6
RISK OF UNSAFE OPERATION HAZARD WHAT CAN HAPPEN HOW TO PREVENT IT All sources of energy include the Operation of Review and understand all of potential for injury. Unsafe generator in the operating instructions and operation or maintenance of your careless manner warnings in this manual. generator could lead to serious Become familiar with the oper- injury or death to you or others. ation and controls of the generator. Know how to shut it off quickly. Equip area of operation with a fire e
ملخص المحتوى في الصفحة رقم 7
RISK OF HOT SURFACES HAZARD WHAT CAN HAPPEN HOW TO PREVENT IT Contact with hot surfaces, such Contact with hot During operation, touch only the as engines exhaust components, engine and control surfaces of the could result in serious burns. generator generator. Keep children away components. from the generator at all times. They may not be able to recog- nize the hazards of this product. RISK OF MOVING PARTS HAZARD HOW TO PREVENT IT WHAT CAN HAPPEN Contact with The generator contains parts Neve
ملخص المحتوى في الصفحة رقم 8
CONSUMER GENERAL AND SERVICE INFORMATION Please read and follow these instructions for proper use and maintenance. If you experience any problems and need assistance, please call us at our toll free number 1-888-559-8550, Monday through Saturday. If repair or service part purchase is required, our many Authorized Warranty Service Centers are conveniently located and equipped to handle all in- warranty and out-of-warranty service. For the location of the nearest Authorized Warranty Servic
ملخص المحتوى في الصفحة رقم 9
ASSEMBLY Read this manual. Do not attempt to operate equipment until you have read this Manual for Safety, Operation, and Maintenance Instructions. NOTE: This manual is a general manual. Information in this manual may or may not pertain to your model. Please read carefully. NOTE: Left and right describes the location of a part with the operator facing the outlet panel. UNPACKING 1. Locate the parts carton and set aside for later use. Protective 2. Cut wire ties holding generator to Wrapping p
ملخص المحتوى في الصفحة رقم 10
1. Lift the gas tank end of generator and slide 2x4 between generator Gas Tank and pallet as shown. The generator is too heavy to be lifted by one person. Obtain assistance from others before lifting. 2x4 2. Place handle grips on handle assemblies. Handle Grip Handle End Cap 3. Place one 5/8” washer into the bottom of Assembly each end cap. Push end caps onto the end of the handle assemblies. 5/8” Washer 4. Attach handle assemblies to frame using four screws and flange nuts. NOTE: Screw on outsi
ملخص المحتوى في الصفحة رقم 11
5. Lift generator and remove 2x4. 6. Lift other end of generator and place two 2x4s between generator and pallet as shown. 2x4 7. On the muffler side of the engine, remove cap screws Cap Muffler and flange nuts holding the heat shield to the frame. Screw Reassemble cap screws, heat shield, wheel bracket, and flange nuts and as shown. Tighten securely. Heat Shield Wheel Bracket Flange Nuts 8. On other side, assemble wheel Cap screws bracket using cap screws and flange nuts supplied. Tighten secu
ملخص المحتوى في الصفحة رقم 12
ASSEMBLE SKYHOOK Tools needed: 1 - 1/2” socket or open end wrench 1 - 3/8" socket 1 - Torque wrench Parts bag contains: 1 - Skyhook 2 - Upper brackets 4 - Bolts, 5/16-18 x 7/8” 4 - Lockwashers, 5/16” 4 - Nuts, Whizlock 5/16” 1. Close fuel shut-off valve on tank by turning clockwise until it stops. 2. Remove four screws, and washers securing fuel tank to frame. Save screws and washers for reassembly. 3. Carefully place fuel tank inside frame rails as shown. 4. Place skyhook under frame as
ملخص المحتوى في الصفحة رقم 13
5. Place skyhook on the fuel tank side of the frame and install upper bracket as shown. 6. Wrap upper bracket around frame. 7. Slide lockwashers onto bolts, insert through brackets, and secure with whizlock nuts. NOTE: DO NOT tighten bolts at this time. 8. Repeat steps 5-7 on other side. 9 Position skyhook between arrows on label. NOTE: Bracket should not overlap onto weld (a). Failure to properly position skyhook a can cause property damage, serious injury or death, and void the manufacturer’
ملخص المحتوى في الصفحة رقم 14
BATTERY INSTALLATION The generator is equipped with a maintenance free battery. 1. For packaging purposes the black Wire Tie negative battery cable and battery were secured with wire ties. Cut Negative Battery Cable these wire ties. 2. Connect black negative cable to negative (-) battery post. Tighten securely. NOTE: Make sure rubber boot is covering positive (+) battery terminal. NOTE: If battery needs to be charged, follow these instructions. Wire Tie When charging the battery, do not smoke.
ملخص المحتوى في الصفحة رقم 15
OBTAINING ELECTRICITY FROM THE GENERATOR There are basically 2 ways to obtain electricity from a generator: 1. Use of extension cords directly from the generator to the appliance, lights, tools, etc. 2. Use of a double-throw transfer switch installed directly to the main electrical supply outside of house. EXTENSION CORDS When using an appliance or tool at a Extension Cord Wire Gauge Chart considerable distance from the generator, Cord Wire Amperage a 3-wire extension cord that has a 3- Length
ملخص المحتوى في الصفحة رقم 16
OTHER LOOSE PARTS 1. Oil is supplied, see engine operator’s manual for correct procedure to add oil and fuel to engine. 2. The locking plugs maybe used when needed or required. The locking plugs are to be installed and/or used in accordance with appropriate local electrical code regulations. Refer to instructions enclosed with each plug for proper installation. 3. 12V DC cables to be used with the 12V DC outlets. See Operation section. IMPORTANT: Before any attempt to start your generator be
ملخص المحتوى في الصفحة رقم 17
IDLE CONTROL Choose the correct application. 1. For normal application such as power tools, small electric appliances, light bulbs, and radios: Place the idle control switch in the ON position. The generator will idle down when there is no load. This lowers the engine noise, saves on fuel consumption, and engine life. 2. Idling down IS NOT recommend on large motors (refrigerators, freezers, etc) or voltage sensitive electronic equipment (computers, televisions, etc). For these applications: Pl
ملخص المحتوى في الصفحة رقم 18
Never fill fuel tank indoors. Never fill fuel tank when engine is running or hot. Do not smoke when filling fuel tank. Never run engine indoors or in enclosed, poor ventilated areas, engine exhaust contains carbon monoxide, an odorless and deadly gas. 3. Make sure generator is grounded in accordance with local requirements. 4. All electrical loads MUST be disconnected. 5. Idle control switch must be in the OFF position. 6. Make sure skyhook bolts are tightened and torqued to 11-12 ft.-lbs. (132-
ملخص المحتوى في الصفحة رقم 19
4. Voltage sensitive equipment should be the last equipment connected to the generator. Plug voltage sensitive appliances such at TV's, VCR's, micro- waves, ovens, computers, and cordless telephones into a UL listed voltage surge protector, then connect the UL listed voltage surge protector to the generator. Failure to connect and operate equipment in this sequence can cause damage to equipment and will void the warranty on your generator. Follow the wattage calculation table in the Wattage Calc
ملخص المحتوى في الصفحة رقم 20
MAINTENANCE CUSTOMER RESPONSIBILITIES TABLE Before Every 25 Every 50 Every 100 each Hours of Hours of Hours of use Every Every Every MAINTENANCE TASK Season Season Season Check oil level See Note 2 X See Note 1 Change oil Clean Air Filter Assembly X X Check Spark Plug X Prepare unit for storage if it is to remain Prepare Unit for Storage idle for more than 30 days. Note 1: Change oil after first two (2) operating hours and every 50 operating hours thereafter, more often if operated in extreme du