ملخص المحتوى في الصفحة رقم 1
l
l
l
l
l
l
l
l
l
l
l
l
l
MO1002-EA
Operation Guide 3134 3205
Battery charges in the light. Battery discharges in the dark.
Getting Acquainted
Bright light
Solar cell
Congratulations upon your selection of this CASIO watch. To get the most out
Electrical
(Converts light to
of your purchase, be sure to read this manual carefully.
energy
electrical power.)
• This watch does not have a time zone that corresponds to the UTC
offset of –3.5 hours. Because of this, the radio-controlled ti
ملخص المحتوى في الصفحة رقم 2
l l l l l l l l Operation Guide 3134 3205 Radio-controlled Atomic Timekeeping Important! This watch receives a time calibration signal and updates its time setting • When getting ready to receive the time calibration signal, position the watch accordingly. as shown in the nearby illustration, with its 12 o’clock side facing towards a • This watch is designed to pick up the time calibration signals transmitted in window. This watch is designed to receive a time calibration signal late at Germany
ملخص المحتوى في الصفحة رقم 3
l l l l l l l l l l l l l l l l l l l l l l l l Operation Guide 3134 3205 About Auto Receive To perform manual receive The watch receives the time calibration signal automatically up to six times a 1. Enter the Receive Mode. Receiving day. When any auto receive is successful, the remaining auto receive 2. Place the watch on a stable surface so its 12 operations are not performed. The reception schedule (calibration times) o’clock side is facing towards a window. depends on your currently select
ملخص المحتوى في الصفحة رقم 4
SE ESE E ENE NE NNE N NNW Operation Guide 3134 3205 Problem Probable Cause What you should do Note Auto receive is •Even if receive is successful, the •Check to make sure the • Note that taking a measurement turned on, but settings updated indicator ( ) watch is in a location while the watch is not horizontal the settings disappears from the display where it can receive the (in relation to the horizon) can updated each day when the first auto signal. result in large measurement error. indicator
ملخص المحتوى في الصفحة رقم 5
l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Operation Guide 3134 3205 Important! 3. Place the watch on a level surface, and position it so that its 12 o’clock position points north (as measured with another compass). • If you want to perform both bidirectional and northerly calibration, be sure 4. Press C to start the calibration operation. to perform bidirectional calibration first, and then perform northerly calibration. This is necessary because bidirectional calibration can
ملخص المحتوى في الصفحة رقم 6
Operation Guide 3134 3205 • If you find it difficult to perform the above step while keeping everything Note that if there are sudden changes in barometric aligned, first move into the correct position (12 o’clock position of the pressure or temperature, the graph line of past watch pointed at the objective) without worrying about the orientation of measurements may run off the top or bottom of the display. the map. Next, perform step 1 again to set the map. The entire graph will become visible
ملخص المحتوى في الصفحة رقم 7
l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Operation Guide 3134 3205 When you measure altitude using a reference altitude specified by you Specifying a Reference Altitude After you specify a reference altitude, the watch uses that value to convert the After you specify a reference altitude, the watch adjusts its air-pressure-to- current measured barometric pressure value to altitude. altitude conversion calculation accordingly. The altitude measurements • When mountain climbing,
ملخص المحتوى في الصفحة رقم 8
l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Operation Guide 3134 3205 Tide/Moon Data Hour 2. While the Moon information (Moon age and In the Tide/Moon Data Mode, you can see the current tide and the current phase) and tide information (current tide level date’s Moon phase for your Home City. You can specify a date and view tide and tide range) are displayed, hold down E and Moon da
ملخص المحتوى في الصفحة رقم 9
l l l l l l l l l l l l l l l l l Operation Guide 3134 3205 Stopwatch Countdown End Beeper Hours The stopwatch lets you measure elapsed time, The watch beeps each second of the final 10 seconds before a countdown split times, and two finishes. 1/100 second reaches zero, and at zero. The first five beeps (seconds 10 through 6) are • The display range of the stopwatch is 23 hours, higher pitched than the final five beeps (seconds 5 through 1). The watch 59 minutes, 59.99 seconds. emits a longer be
ملخص المحتوى في الصفحة رقم 10
l l l l l l Operation Guide 3134 3205 Alarms • The auto light switch is always disabled, regardless of its on/off setting, You can set five independent daily alarms. When Alarm number when any one of the following conditions exists. an alarm is turned on, the alarm tone sounds While an alarm is sounding when the alarm time is reached. During sensor measurement You also can turn on an Hourly Time Signal, While a bearing sensor calibration operation is being performed in the which will cause the w
ملخص المحتوى في الصفحة رقم 11
l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Operation Guide 3134 3205 Battery Power Indicators 14000 ft 19.03 inHg 16.2°F The battery power indicator on the display shows you the current status of the 12000 ft About 0.15 inHg per 200 ft 10000 ft rechargeable battery’s power. 22.23 inHg 30.5°F 8000 ft About 0.17 inHg per 200 ft About 3.6°F per 1000 ft 6000 ft About 0.192 inHg per 200 ft 25.84 inHg 44.7°F Level Battery Power Function Status 4000 ft 2000 ft Indicator
ملخص المحتوى في الصفحة رقم 12
l l l l l l l l l l l l l l l l Operation Guide 3134 3205 Recovery Times Screen To do this: Do this: The table below shows the amount exposure that is required to take the 00 Reset the seconds to Press A . battery from one level to the next. Approximate Exposure Time Exposure Level Change the hour or minute Use A (+) and C (–). (Brightness) Level 5 Level 4 Level 3 Level 2 Level 1 Change the year Outdoor Sunlight 1 hour 12 hours 4 hours (50,000 lux) Change the month or day Sunlight Thro
ملخص المحتوى في الصفحة رقم 13
l l l l l l l Operation Guide 3134 3205 Moon Phase Indicator Auto Return Features The Moon phase indicator of this watch indicates • The watch returns to the Timekeeping Mode automatically if you do not Moon Phase indicator perform any button operation for two or three minutes in the Tide/Moon the current phase of the Moon as shown below. It Data, Alarm, Data Recall, Receive, Digital Compass, or Barometer/ is based on the view of the left side of the moon Thermometer Mode. at meridian transit fr
ملخص المحتوى في الصفحة رقم 14
l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l l Operation Guide 3134 3205 To recover from the sleep state Illumination Precautions Perform any one of the following operations. • The electro-luminescent panel that provides illumination loses power after • Move the watch to a well-lit area. It can take up to two seconds for the very long use. • Illumination may be hard to see when viewed under direct sunlight. display to turn on. • Illumination turns off automatically whenever an ala
ملخص المحتوى في الصفحة رقم 15
l l l l l l l Operation Guide 3134 3205 3. Use A (+) and C (–) to set the calibration value in the units shown below. Pressure Sensor Precision: Temperature 0.1°C (0.2°F) Conditions Altimeter Barometer Barometric Pressure 1 hPa (0.05 inHg) (Altitude) • “OFF” is displayed while the reference temperature value and barometric Fixed 0 to 6000 m ± (altitude differential × 3% ± (pressure differential × 3% tempera- 0 to 19680 ft. + 30 m) m + 3 hPa) hPa pressure value are zero (0). ture ± (altitude diff