                        installation & Operating Manual
P61A Pellet Stove Owners Manual
“Ce manuel est disponible en Français sur demande”
R17
SAFetY nOtice
PleASe ReAd thiS entiRe MAnuAl beFORe YOu inSt All And uSe YOuR new ROOM heA teR.  F AiluRe 
t O FOllOw inStRuctiOnS MAY ReSult in PROPeRtY dAMAge, bOdil Y injuRY , OR even deA th.
FOR uSe in the u.S. And cAnAdA.  Suit Able FOR inSt AllA tiOn in MObile hOMeS.
iF thiS hARMAn St Ove iS nOt PROPeRl Y inSt Alled, A hOuSe FiRe MAY ReSult .  FOR YOuR SAFetY, FOl-
lOw inS
                    
                    ملخص المحتوى في الصفحة رقم 2 
                    
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                            
                    
                    ملخص المحتوى في الصفحة رقم 3 
                    
                        8cm min 3"min 3 P61A Pellet Stove The Label Pictured Is For Reference Only. For specific infor- mation regarding testing and clearances, consult the actual  label on the rear of the stove. Harman P61A Pellet Stove Label measures: 4-3/8" high X 10-3/4"wide Black Background with bare metal for print-adhesive backed, metal plate. MODEL / MODÈLE:    "P61A" Ser# - 008 Appareil de chauffage à granulés de bois Utilisable dans des mobile homes. Cet  Tested and    Portland  Room Heater Pellet Fuel Burnin
                    
                    ملخص المحتوى في الصفحة رقم 4 
                    
                        t able of contents Safety Information       5 Installation     6 Venting     8 ESP Control                15 Automatic Operation   16 Manual Operation    19 Low Draft Voltage Adjustment  21 Maintenance     22 Troubleshooting    27 Fuel Specifications    28 Mixing Corn with Pellets   29 Power Failure / Back-up   30 Options     31 Wiring Diagram    32 Specifications    32 Warranty     33 Service Parts     35 Listed by: OMni-Test Laboratories, Inc.  Report #: 135-S-22-4 Meets requirements of :  AST
                    
                    ملخص المحتوى في الصفحة رقم 5 
                    
                               iMPORt Ant nOteS wARning dO nOt inSt All A Flue dAMPeR in the  M O b i l e / M A n u FA c t u R e d h O M e  eXhAuSt venting SYSteM OF thiS  S t A n d A R d S d O n O t A l l O w  unit . inSt AllA tiOn in ROOMS deSignA ted  FOR SleePing. dO nOt cOnnect thiS unit t O A  chiMneY Flue SeR ving AnOtheR  cAutiOn  APPliAnce. the StRuctuRAl integRitY OF the  MObile hOMe FlOOR, w All, And  ceiling/ROOF MuSt be MAint Ained. SPeciAl nOte:  due t O Fl Y ASh builduP , it iS StROngl Y  MObile hOMe inS
                    
                    ملخص المحتوى في الصفحة رقم 6 
                    
                               Assembly and installation unpacking The P61A is bolted (1/4 x 1" hex head bolts) to the  skid to prevent movement during shipping.  To free the stove from the skid you must remove the  hold-down bolts in the rear of the pedestal base. Removing rear cover panels The rear cover panels are secured to the stove  with three bolts each. Two of the bolts need only be  loosened, not removed, to remove the panels. It is  recommended that the rear covers are installed after  the unit is in place an
                    
                    ملخص المحتوى في الصفحة رقم 7 
                    
                        installation installing  Place the stove on a noncombustible floor or on a floor  protector that extends a minimum of 6 inches to the front,  9" or 13" (measured from the glass) 6 inches to the sides and 1 inch  to the rear of the hopper. It is also recommended that floor  protection be installed under any horizontal venting and ex- tending 2 inches beyond the vent measurement. Material used  for floor protection must be a minimum 3/8" of material rated  9" or 13" at 0.84k per inch. Another meth
                    
                    ملخص المحتوى في الصفحة رقم 8 
                    
                        venting Requirements for t erminating the venting I. The clearance to service regulator vent outlet must  WARNING: Venting terminals must not be recessed  1 be a minimum of 6 feet. into a wall or siding. J. The clearance to a non-mechanical air supply inlet  NOTE: Only approved pellet vent pipe, wall pass- to the building or the combustion air inlet to any other  throughs, and fire stops should be used when venting  1 appliance must be a minimum of 48”. through combustible materials. K. The clea
                    
                    ملخص المحتوى في الصفحة رقم 9 
                    
                        venting vent Pipe iMPORt Ant nOtice      Pellet venting pipe (known as PL vent) is constructed  Approved Pellet Vent Pipe- Widely Known As   of two layers with air space between the layers.  "PL Vent",  Must be used. This air space acts as an insulator and reduces the  outside surface temperature to allow a clearance to  combustibles of 1 to 3 inches. The sections of pipe  lock together to form an air tight seal in most cases.  However, in some cases a perfect seal is not achieved.  For this rea
                    
                    ملخص المحتوى في الصفحة رقم 10 
                    
                        venting Per national building codes, consideration must be  given to combustion air supply to all combustion appli- ances. Failure to supply adequate combustion air for all  Outside air flex pipe  appliance demands, may lead to back-drafting of those  goes here. and other appliances.  When the appliance is side-wall vented: The air in- take is best located on the same exterior wall as the  exhaust vent outlet and located lower on the wall than  the exhaust vent outlet. When the appliance is roof
                    
                    ملخص المحتوى في الصفحة رقم 11 
                    
                        venting #1 Preferred method  This method provides excellent venting for  normal operation and allows the stove to be in- stalled closest to the wall. Two inches from the wall  is safe; however, four inches allows better access  to remove the rear panel. The vertical portion of the  vent should be three to five feet high. This vertical  section will help provide natural draft in the event of  a power failure. note: do not place joints within  3 ft. wall pass-throughs. to combustibles Fig. 8 3 ft.
                    
                    ملخص المحتوى في الصفحة رقم 12 
                    
                        venting #4 installing into an existing  chimney        This method provides excellent venting for  normal operation. This method also provides  natural draft in the event of a power failure. If the  chimney condition is questionable* you may want  to install a liner as in method #7.  In some places in the US and Canada it is  required that the vent pipe extend all the way to the  top of the chimney. *The chimney should be inspected and cleaned  before installing your stove. If you discover that 
                    
                    ملخص المحتوى في الصفحة رقم 13 
                    
                        venting #6 installing into an existing fireplace  chimney  This method provides excellent venting for  normal operation. This method also provides natural  draft in the event of a power failure.  In some places in the US and Canada it is re- quired that the vent pipe extend all the way to the top  of the chimney. The pipe or liner inside the chimney  should be 4" diameter. In this method a cap should also be installed  on the chimney to keep out rain. Be sure to use ap- proved  pellet vent pipe 
                    
                    ملخص المحتوى في الصفحة رقم 14 
                    
                        venting Storm collar Flashing 3" min. 3" min. 3" min. PL vent manufacturer's  firestop spacer and  Minimum flue vent  No insulation or  support other combustible  configuration m a t e r i a l s a r e  It is recommended that outside  a l l o w e d w i t h i n  3" of the pellet  air be installed with this venting  vent pipe. Unless  configuration to reduce smoke  specified by the  and creosote smell in the room  pipe manufacturer in the event of power failure. (See Page 7 for  corner installation
                    
                    ملخص المحتوى في الصفحة رقم 15 
                    
                        Aut OMAtic ignitiOn  eSP  cOntROl Feed adjuster Power Light Sets the maximum  Indicates power to the  feed rate. control.       Test Runs all motors at full  speed for one minute  Status Light to check operation.  Will be lit in either stove  Afterward the control  or room temp mode  w i l l s i m u l a t e a  when pointer is not  minimum burn and the  within off position band  combustion blower will  except after normal shut  remain on low, with the  down. Blinks to indicate  distribution blowe
                    
                    ملخص المحتوى في الصفحة رقم 16 
                    
                         Aut OMAtic  ignitiOn/OPeRA tiOn The P61A is a fully automatic stove that features two  Room t emperature Mode operating modes; Stove t emperature Mode and Room  t emperature Mode. In Stove Temperature Mode, you  select a burn rate and the stove will remain at the same  burn rate regardless of the room temperature.  In the Room Temperature Mode the stove constantly  monitors the temperature in the room and adjusts the  size of the fire and the heat output of the stove so that the  room is kept a
                    
                    ملخص المحتوى في الصفحة رقم 17 
                    
                         Aut OMAtic  ignitiOn/OPeRA tiOn Stove t emperature Mode Shut down Procedure In the Stove Temperature Mode and with the igniter  The best way to shut down the stove is to simply let it  toggle switch in the Auto position, the stove will light  run out of pellets. The stove will shut down automatically.   automatically and can be adjusted to the desired setting  Alternatively, you can turn the Mode Selector to “off”.   using the same temperature control dial as is used in  This will cause the fir
                    
                    ملخص المحتوى في الصفحة رقم 18 
                    
                        Aut OMAtic  St ARt  uP Starting First Fire igniter Switch to "Aut O" (up position) Make sure the unit is plugged into a 120 VAC, 60  HZ electrical source. The power light should be the  only light lit. See Hint #7. Fig. 17 Flame Guide nOtice: be sure there is no unburned fuel  1" or other combustibles in the ash pan prior  to lighting. 1. t urn Mode Selector to "OFF". 1 2. Fill hopper with pellets. 5 3. clean burn pot with scraper, if necessary. 4. if starting after an empty hopper, turn Feed  2
                    
                    ملخص المحتوى في الصفحة رقم 19 
                    
                        MAnuAl  ignitiOn/OPeRA tiOn The P61A Pellet Stove is capable of manual operation. This also allows the operator  to manually control operation during an emergency (i.e. igniter failure, when using a  502H battery backup, as opposed to the 512H, or when using certain generators.) The unit can be switched between "AUTO" and "MANUAL" at any time during op- eration. nOte: when starting the unit in the "Aut O"  mode and switching to "MAnu Al ", the ignition  Room Temperature Mode: This  cycle must be
                    
                    ملخص المحتوى في الصفحة رقم 20 
                    
                        MAnuAl  St ARt  uP Starting First Fire igniter Switch to "MAnuAl"  Fig. 20 (down position)  Make sure the unit is plugged into a 120  VAC, 60 HZ electrical source. The power light  should be the only light lit. Fig. 19 nOtice: be sure there is no unburned fuel  See Hint #7. or other combustibles in the ash pan prior  1" to lighting. 1. t urn Feed AdjuSteR to desired feed rate.  4 No. 4 is good for most pellets. 2. t urn the MOde Select OR to “OFF” and  then to the desired mode.  This will reset