ملخص المحتوى في الصفحة رقم 1
MODEL 384
MAY BE INSTALLED IN A SOLID FUEL BURNING FIREPLACE, AS A
FREESTANDING FIREPLACE, AS A ZERO CLEARANCE FIREPLACE OR
WITH AN OPTIONAL WOODEN SURROUND
VENT-FREE
WARNING: If the information in this manual is not followed exactly, a fire or
explosion may result causing property damage, personal injury or loss of life.
− Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
• Do
ملخص المحتوى في الصفحة رقم 2
ملخص المحتوى في الصفحة رقم 3
TABLE OF CONTENTS SECTION I: Safety Information ........................................................................................ 1 SECTION II: Fireplace Preparation ................................................................................... 4 Fireplace Clearances ........................................................................................................... 5 Gas Connection .........................................................................................
ملخص المحتوى في الصفحة رقم 4
ملخص المحتوى في الصفحة رقم 5
SECTION I SAFETY INFORMATION WARNINGS IMPORTANT: READ THIS OWNER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING TO ASSEMBLE, OPERATE, OR SERVICE THE APPLIANCE. IMPROPER USE OF THESE LOGS CAN CAUSE SERIOUS INJURY OR DEATH FROM BURNS, FIRE, EXPLOSION, AND CARBON MONOXIDE POISONING. Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, and/or nausea. If you have these signs, the heater may not be working properly. Get f
ملخص المحتوى في الصفحة رقم 6
5. If this heater is used with propane gas, do not place propane supply tank (s) inside any structure. 6. What To Do IF You Smell Gas: Shut off gas supply. - Do not try to light any appliance. - Do not touch any electrical switch; do not use any phone in your building. - Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. - If you cannot reach your gas supplier, call the fire department. 7
ملخص المحتوى في الصفحة رقم 7
20. All heater screens must be kept closed when operating the gas logs. 21. “WARNING: Failure to keep the primary air opening(s) of the burner(s) clean may result in sooting and property damage.” 22. Do not use this heater for burning trash or cooking. Never place matches, paper, garbage, or any other material on top of logs or into the flames. 23. Do not install or operate this heater in areas where impurities in the air exist (such as tobacco smoke or heavy cooking grease). Pa
ملخص المحتوى في الصفحة رقم 8
SECTION II FIREPLACE PREPARATION The fireplace needs to be prepared before installing the heater. A. Turn off the gas supply to the fireplace. WARNING: BEFORE INSTALLING IN A SOLID-FUEL BURNING FIREPLACE, THE CHIMNEY FLUE AND FIREBOX MUST BE CLEANED OF SOOT, CREOSOTE, ASHES, AND LOOSE PAINT BY A QUALIFIED CHIMNEY CLEANER. “WARNING: DO NOT ALLOW FANS TO BLOW DIRECTLY INTO THE FIREPLACE. AVOID DRAFTS THAT ALTER BURNER FLAME PATTERNS.” “WARNING: DO NOT USE A BLOWER I
ملخص المحتوى في الصفحة رقم 9
INSTALLATION AND CLEARANCES To ensure a safe installation into a masonry or factory built fireplace, the following instructions must be carefully followed: (1) Sidewall Clearances: Clearance from the side of the fireplace opening to any adjacent combustible wall should not be less than: right side 7", left side 7". (2) Ceiling Clearances: The ceiling height should not be less than 26" from the top of the fireplace opening. (3) Mantel Clearances: Clearances from top of heat
ملخص المحتوى في الصفحة رقم 10
CR3329 CERAMIC LOG SET PLACEMENT FOR MODEL 384 (3) (4) (2) (1-R) (1-L) WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. WA
ملخص المحتوى في الصفحة رقم 11
EMBER STOVE LOG SET PLACEMENT FOR MODEL 384 4 3 1 2 6 5 7 “MILLIVOLT ONLY” WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury. WARNING: POSITIONING OF LOGS IS VERY CRI
ملخص المحتوى في الصفحة رقم 12
GAS PRESSURE CHECK Check the inlet pressure to the burner to ensure that it is as shown in the table below. NOTE: The pressure check point is located on the right side of the valve facing burner, for SIT Millivolt, and the left side for SIT Modulating. The appliance and its appliance main gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5kPa). The appliance must be isolated from the g
ملخص المحتوى في الصفحة رقم 13
LIGHTING INSTRUCTION MODULATING OR MANUAL VALVE (SIT) FOR YOUR SAFETY READ BEFORE LIGHTING WARNING IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.” A. This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly. B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor becaus
ملخص المحتوى في الصفحة رقم 14
LIGHTING INSTRUCTION 1. STOP! Read the safety information on preceding page 9. 2. Make sure manual shutoff valve is fully closed. 3. Turn off all electrical power to the appliance. 4. Open access panel door located at bottom front of the appliance. 5. Turn control knob clockwise to the full “OFF” position. 6. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow
ملخص المحتوى في الصفحة رقم 15
11. Turn gas control knob counterclockwise to “ON” position. Continue to turn the gas control knob counterclockwise to your desired setting. 12. Close access panel door. 13. Turn on all electrical power to the appliance. CAUTION DO NOT TRY TO ADJUST HEATING LEVELS BY USING THE MANUAL SHUTOFF VALVE. TO TURN OFF GAS TO APPLIANCE SHUTTING OFF UNIT 1. Open access cover door. 2. Turn gas control knob clockwise
ملخص المحتوى في الصفحة رقم 16
THERMOSTAT CONTROL OPERATION 1. The thermostat control on this heater differs from standard thermostats. Standard thermostats simply turn the burner on and off. The thermostat used on this heater senses the room temperature and adjusts the amount of gas flow to the burner. This will increase or decrease the flame height. At times, the room may exceed the set temperature, which will cause the burner to shut off. When room temperature drops below the thermostat setting, the burner wil
ملخص المحتوى في الصفحة رقم 17
OPERATING INSTRUCTIONS Before operating this appliance, proceed through the following checklist. 1. Read and understand these instructions before operating this appliance. 2. Check that there are no gas leaks. If you smell gas do not attempt to light this appliance. 3. Verify that log placement is correct. LIGHTING INSTRUCTIONS SIT-MILLIVOLT VALVE FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion ma
ملخص المحتوى في الصفحة رقم 18
LIGHTING INSTRUCTIONS 1. STOP! Read the safety information on the reverse side of this label (page 13). 2. Make sure manual shutoff valve is fully closed. If equipped with thermostat, set to the low- est setting. 3. Turn off all electrical power to the appliance. 4. Open access door located at bottom of front of the appliance. 5. Push in gas control knob slightly and turn clockwise to the full “OFF” position. REMOTE CONTROL OR WALL THER
ملخص المحتوى في الصفحة رقم 19
* If the pilot will not stay lit after several tries, turn the gas control knob to “OFF” and call your service technician or gas supplier. 11. Turn control knob counterclockwise to “ON”. 12. If using unit without wall thermostat place Auto/Off/Manual switch into the manual position. If using wall thermostat place Auto/Off/Manual Switch into the auto position and place thermostat to a setting higher than the room temperature. 13. Close access cover door. 14. “Turn on a
ملخص المحتوى في الصفحة رقم 20
MANUAL LIGHTING PROCEDURE 1. If the pilot cannot be lit with the piezo, it can be manually lit with the use of a paper match and a lighter rod. 2. Open access panel door located at bottom front of the appliance. 3. Place the match in the holder and light. With the left hand, turn the control knob counterclockwise to “PILOT”position. Press in gas control knob for fifteen (15) seconds. 4. Use rod to light match and ignite pilot. The pilot is located in front of the re