ملخص المحتوى في الصفحة رقم 1
DO NOT
DISCARD
Owner ’ s Manual
Installation and Operation
Model:
XLR-PLUS-N-AU
XLR-PLUS-PB-AU
SAI Global
Ref No GSCS20194
AS4553:2008
NOTICE
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow
• Leave this manual with
and maintenance these instructions for safe
party responsible for use
instructions included. installation and operation. and operation.
W ARNING
W ARNING: I f t h e i n f o r m a t i o n i n t h e s e
HOT SURFACES!
i n s t r u c t i o n s
ملخص المحتوى في الصفحة رقم 2
PLEASE READ THIS MANUAL BEFORE INSTALLING AND USING THIS APPLIANCE. MODELS: XLR-PLUS-N-AU, follow these instructions carefully during installation to ensure maximum benefit and XLR-PLUS-PB-AU safety. Failure to follow them will void your A R E S A I G L O B A L A P P R O V E D F O R warranty and may present a fire hazard. N A T U R A L G A S , P R O P A N E O R B U T A N E The Heat & Glo, a brand of Hearth & Home AS A BALANCED FLUE HEA TER. Technolog
ملخص المحتوى في الصفحة رقم 3
SAMPLE Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. This owner’s manual should be retained for future A. Congratulations reference. We suggest that you keep it with your other Congratulations on selecting a Heat & Glo gas fireplace, an important documents and product manuals. elegant and clean alternative to wood burning fireplaces. The information contained in this owner’s manual, unless The Heat & Glo gas firepla
ملخص المحتوى في الصفحة رقم 4
Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Used to address practices not related to personal injury. T able of Contents A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . .
ملخص المحتوى في الصفحة رقم 5
F. Blower . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 G. Control Module Operation . . . . . . . . . . . . . . . . . . . . . . . . 46 13 Finishing A. Framing and Finishing Instructions . . . . . . . . . . . . . . . . . 53 B. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 56 C. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 D. Decorative Fronts . . . . . . . . . . . . . . . . . . . . . . . . .
ملخص المحتوى في الصفحة رقم 6
B. Limited Lifetime W arranty AUSTRALIAN W ARRANTY INFORMA TION Warranty information in the attached manual is for international markets, not Australia. For Australian warranty information, please see below. Hearth & Home T echnologies Inc (HHT) 7571 215th Street W est, Lakeville, MN 55044 001 1-1-651-345-1777 www .heatnglo.com HHT extends the following manufacturer’s warranty for HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorised dealer. H
ملخص المحتوى في الصفحة رقم 7
Warranty Period Heat & Glo Manufactured Appliances and Venting Components Covered EPA Parts Labor Gas Wood Pellet Coal Electric Venting Wood 5 years 1 years X X Castings & baffl es Manifold tubs HEAT & GLO 7 years 3 years X X X chimney and termination 10 years 1 year X Burners, logs and refractory Limited 3 year X X X X X Firebox and heat exchanger Lifetime All Replacement Parts 90 Days X X X X X X X beyond warranty period OTHER RIGHTS The HHT manufacturer ’ s warranty is in addition to other
ملخص المحتوى في الصفحة رقم 8
• Non Heat & Glo venting components, hearth components or other accessories used in conjunction with the appliance. • Any part of a pre-existing fi replace system in which an insert or a decorative gas appliance is installed. • Removal, installation, reinstallation, set up or any other costs associated with a claim including travel and shipping charges for parts • HHT’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Informa- tion is provi
ملخص المحتوى في الصفحة رقم 9
L i s t i n g a n d C o d e A p p r o v a l s 1 A. Appliance Certification C. High Altitude Installations NOTICE: If the heating value of the gas has been reduced, MODELS: XLR-PLUS-N-AU, XLR-PLUS-PB-AU these rules do not apply. Check with your local gas utility or authorities having jurisdiction. LABORATORY: SAI Global TYPE: Gas Space Heating Appliance When installing above 2000 ft. (610 m) elevation: STANDARD: AS4553:2008 Reduce input rate 4% for each 1000 ft. (305 m) above 2000 ft
ملخص المحتوى في الصفحة رقم 10
User Guide O p er a t i n g I n s t r u c t i o n s 2 • Install a physical barrier such as: A. Gas Fireplace Safety - A decorative firescreen. W ARNING - Adjustable safety gate. • Install a switch lock or a wall/remote control with child HOT SURFACES! protection lockout feature. Glass and other surfaces are hot during operation AND cool down. • Keep remote controls out of reach of children. Hot glass will cause burns. • Never leave children alone near a hot fireplace, whether • DO NOT
ملخص المحتوى في الصفحة رقم 11
CLEAR SPACE 3 FT. IN FRONT OF FIREPLACE C. Clear Space F . Fixed Glass Assembly WARNING! DO NOT place combustible objects in front See Section 14.E. of the fireplace or block louvers. High temperatures may start a fire. See Figure 2.2. G. Remote Controls, W all Controls and W all Avoid placing candles and other heat-sensitive objects on Switches mantel or hearth. Heat may damage these objects. Follow the instructions supplied with the control installed to operate your fireplace: F
ملخص المحتوى في الصفحة رقم 12
I. Lighting Instructions (IPI) The IPI system may be operated with four C-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer. FOR YOUR S AFETY LIGHTING READ BEFORE LIGHTING INSTRUCTIONS (IPI) W A R N I N G : If you do not follow these instructions exactly, a fire or explosion 1. This appliance is equipped with an ignition may result causing property damage, personal injury or loss of life. device which automaticall
ملخص المحتوى في الصفحة رقم 13
J. Control Module Operation Nine Hour Safety Shutdown Feature 1. The control module has an ON/OFF/REMOTE selector This appliance has a safety feature that automatically switch that must be set. shuts down the fireplace after 9 hours of continuous OFF Position: Appliance will ignore all power inputs and operation without receiving a command from the wall will not respond to any commands from a wall switch or switch or optional remote. optional remote. The unit should be in the OFF posi
ملخص المحتوى في الصفحة رقم 14
K. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • Turn the fireplace off and allow it to completely cool. • Remove fixed glass assembly. See Section 14.E. • Clean fixed glass assembly. See Section 3.A. • Replace the fixed glass assembly and run continuously on high an additional 12 hours. This cures the materials used to manufacture the fire- place. NOTICE! Open windows for air circulation during fire- place break-in
ملخص المحتوى في الصفحة رقم 15
M a i n t e n an c e an d S er v i c e 3 Decorative Doors Any safety screen or guard removed for servicing must be Frequency: Annually replaced prior to operating the fireplace. By: Homeowner When properly maintained, your fireplace will give you T ools needed: Protective gloves, stable work surface many years of trouble-free service. We recommend an- • Refer to the installation instructions which ship with the nual service by a qualified service technician. decorative door. • Asses
ملخص المحتوى في الصفحة رقم 16
B. Maintenance T asks-Qualified Service Burner Ignition and Operation T echnician Frequency: Annually The following tasks must be performed by a qualified ser- By: Qualified Service Technician vice technician. T ools needed: Protective gloves, vacuum cleaner, whisk Gasket Seal and Glass Assembly Inspection broom, flashlight, voltmeter, indexed drill bit set, and a manometer. Frequency: Annually • Verify burner is properly secured and aligned with pilot By: Qualified Service Technici
ملخص المحتوى في الصفحة رقم 17
Installer Guide G e t t i n g S t a r t ed 4 A. T ypical Appliance System NOTICE: Illustrations and photos reflect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual N o t e : Dual venting configurations HORIZONTAL TERMINATION CAP ARE NOT allowed. Appliance MUST (SECTION 10.K) be vented E I T H E R vertically OR horizontally. WALL PENETRATION VERTICAL TERMINATION CAP FRAMING (SECTION
ملخص المحتوى في الصفحة رقم 18
B. Design and Installation Considerations D. Inspect Appliance and Components Heat & Glo direct vent gas appliances are designed to • Carefully remove the appliance and components from operate with all combustion air siphoned from outside of the packaging. the building and all exhaust gases expelled to the outside. • The vent system components and decorative doors and No additional outside air source is required. fronts may be shipped in separate packages. Before installing, determine th
ملخص المحتوى في الصفحة رقم 19
F r a m i n g a n d C l e a r an c e s 5 NOTICE: Illustrations reflect typical installations and are A. Selecting Appliance Location FOR DESIGN PURPOSES ONLY. Illustrations/diagrams When selecting a location for the appliance it is important to are not drawn to scale. Actual installation may vary due to consider the required clearances to walls (see Figure 5.1). individual design preference. WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service
ملخص المحتوى في الصفحة رقم 20
B. Constructing the Appliance Chase C. Clearances A chase is a vertical box-like structure built to enclose the NOTICE: Install appliance on hard metal or wood surfaces gas appliance and/or its vent system. In cooler climates extending full width and depth. DO NOT install directly the vent should enclosed inside the chase. on carpeting, vinyl, tile or any combustible material other than wood. NOTICE: Treatment of ceiling firestops and wall shield firestops and construction of the chase ma