DO NOT
DISCARD
Para obtener un ejemplar en Español de este Pour demander un exemplaire en français de ce Manuel
Manual del propietario, visite www.heatnglo.com. du propriétaire, visitez www.heatnglo.com.
Owner’s Manual
Installation and Operation
Models:
8000CF-OAK-IPI
8000CFLP-OAKIPI
NOTICE
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow • Leave this manual with
and maintenance these instructions for safe
party responsible for use
instructions included. instal
ملخص المحتوى في الصفحة رقم 2
Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. This owner’s manual should be retained for future A. Congratulations reference. We suggest that you keep it with your other Congratulations on selecting a Heat & Glo gas fi replace, an important documents and product manuals. elegant and clean alternative to wood burning fi replaces. The information contained in this owner’s manual, unless The Heat & Glo gas fi replace you h
ملخص المحتوى في الصفحة رقم 3
Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Used to address practices not related to personal injury. Table of Contents A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ملخص المحتوى في الصفحة رقم 4
13 Finishing A. Mantel and Wall Projections . . . . . . . . . . . . . . . . . . . . . . . 45 B. Facing Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 14 Appliance Setup A. Remove Fixed Glass Assembly . . . . . . . . . . . . . . . . . . . . 46 B. Remove the Shipping Materials . . . . . . . . . . . . . . . . . . . . 46 C. Clean the Appliance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46 D. Accessories . . . . . . . . . . . . . . . . . . . . . . . .
ملخص المحتوى في الصفحة رقم 5
B. Limited Lifetime Warranty Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 5
ملخص المحتوى في الصفحة رقم 6
B. Limited Lifetime Warranty (continued) 6 Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09
ملخص المحتوى في الصفحة رقم 7
Listing and Code Approvals 1 1 A. Appliance Certifi cation C. BTU Specifi cations Maximum Minimum Orifi ce MODELS: 8000CF-OAK-IPI, 8000CFLP-OAKIPI Model Input Input Size (U.S. or Canada) (DMS) BTU/h BTU/h LABORATORY: Underwriters Laboratories, Inc. (UL) US TYPE: Direct Vent Gas Appliance Heater 36,500 28,000 31 (0-2000 FT) 8000CF-OAK-IPI (NG) STANDARD: ANSI Z21.88-2000 • CSA2.33-M98 • UL307B CAN 32,850 25,200 32 (2000-4500 FT) US 37,500 30,000 1.8 mm This product is listed to ANSI standar
ملخص المحتوى في الصفحة رقم 8
Inspection Note: The following requirements reference various The state or local gas inspector of the side wall horizon- Massachusetts and national codes not contained in this tally vented gas fueled equipment shall not approve the document. installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed H. Requirements for the Commonwealth of in accordance with the provisions of 248 CMR 5.08(2)(a)1 Massachusetts through 4. For all side wall
ملخص المحتوى في الصفحة رقم 9
User Guide Operating Instructions 2 2 • Install a switch lock or a wall/remote control with child A. Gas Fireplace Safety protection lockout feature. • Keep remote controls out of reach of children. WARNING • Never leave children alone near a hot fi replace, whether HOT SURFACES! operating or cooling down. Glass and other surfaces are hot during operation AND cool down. • Teach children to NEVER touch the fi replace. Hot glass will cause burns. • Consider not using the fi replace when childr
ملخص المحتوى في الصفحة رقم 10
CLEAR SPACE 3 FT. IN FRONT OF FIREPLACE C. Fan Kit (optional) F. Fixed Glass Assembly If desired, a fan kit may be added. Contact your dealer to See Section 14.I. order the correct fan kit. G. Remote Controls, Wall Controls and Wall D. Clear Space Switches WARNING! DO NOT place combustible objects in front Follow the instructions supplied with the control installed of the fi replace or block louvers. High temperatures may to operate your fi replace: start a fi re. See Figure 2.2. For safety:
ملخص المحتوى في الصفحة رقم 11
I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer. FOR YOUR SAFETY LIGHTING READ BEFORE LIGHTING INSTRUCTIONS (IPI) WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. 1. Turn off all electric power to the appliance. • Immediately call your gas supplie
ملخص المحتوى في الصفحة رقم 12
J. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • Turn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly. See Section 14.I. • Clean fi xed glass assembly. See Section 3. • Replace the fi xed glass assembly and run continuously on high an additional 12 hours. This cures the materials used to manufacture the fi re- place. NOTICE! Open windows for air circulation during fi re- place break-in. •
ملخص المحتوى في الصفحة رقم 13
Maintenance and Service 3 3 Doors, Surrounds, Fronts Any safety screen or guard removed for servicing must be replaced prior to operating the fi replace. Frequency: Annually By: Homeowner When properly maintained, your fi replace will give you many years of trouble-free service. We recommend an- Tools needed: Protective gloves, stable work surface nual service by a qualifi ed service technician. • Assess condition of screen and replace as necessary. A. Maintenance Tasks-Homeowner • Insp
ملخص المحتوى في الصفحة رقم 14
• Replace fi replace if fi rebox has been perforated. Venting Frequency: Seasonally Control Compartment and Firebox Top By: Homeowner Frequency: Annually Tools needed: Protective gloves and safety glasses. By: Qualifi ed Service Technician • Inspect venting and termination cap for blockage or Tools needed: Protective gloves, vacuum cleaner, dust obstruction such plants, bird nests, leaves, snow, debris, cloths etc. • Vacuum and wipe out dust, cobwebs, debris or pet hair. • Verify terminati
ملخص المحتوى في الصفحة رقم 15
(Either cobrahead or SIT) Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • 8000CF-OAK-IPI • 2059-900 Rev. R • 6/09 15
ملخص المحتوى في الصفحة رقم 16
Installer Guide Getting Started 4 4 A. Typical Appliance System NOTICE: Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual HORIZONTAL TERMINATION CAP Note: Dual venting configurations (SECTION 10.I) ARE NOT allowed. Appliance MUST be vented EITHER vertically OR horizontally. VERTICAL TERMINATION CAP (SECTION 10.G) NON-COMBUSTIBLE ROOF FLASHING MAINTAINS
ملخص المحتوى في الصفحة رقم 17
B. Design and Installation Considerations D. Inspect Appliance and Components Heat & Glo direct vent gas appliances are designed to • Carefully remove the appliance and components from operate with all combustion air siphoned from outside of the packaging. the building and all exhaust gases expelled to the outside. • The vent system components and decorative doors and No additional outside air source is required. fronts may be shipped in separate packages. Installation MUST comply with loca
ملخص المحتوى في الصفحة رقم 18
Framing and Clearances 5 5 NOTICE: Illustrations refl ect typical installations and are A. Selecting Appliance Location FOR DESIGN PURPOSES ONLY. Illustrations/diagrams When selecting a location for the appliance it is important to are not drawn to scale. Actual installation may vary due to consider the required clearances to walls (see Figure 5.1). individual design preference. WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access. Due to
ملخص المحتوى في الصفحة رقم 19
To further prevent drafts, the wall shield and ceiling fi re- B. Constructing the Appliance Chase stops should be caulked with high temperature caulk to A chase is a vertical box-like structure built to enclose the seal gaps. Gas line holes and other openings should be gas appliance and/or its vent system. In cooler climates caulked with high temp caulk or stuffed with unfaced in- the vent should be enclosed inside the chase. sulation. If the appliance is being installed on a cement NOTICE:
ملخص المحتوى في الصفحة رقم 20
Combustible Mantel Legs or Wall Projections D. Mantel and Wall Projections WARNING! Risk of Fire! Comply with all minimum clear- ances as specifi ed. Framing or fi nishing material closer than the minimums listed must be constructed entirely of noncom- bustible materials (i.e., steel studs, concrete board, etc). Combustible Mantels 18 1 in. MIN. 14-1/4 Note: All TOP VIEW measurements 10-1/2 in inches. 6-3/4 3 in. 3 3 ft. MIN. MAX. Figure 5.4 Combustible Mantel Leg or Wall Projections 12-1/4 (