ملخص المحتوى في الصفحة رقم 1
DO NOT
DISCARD
Owner’s Manual
Installation and Operation
Models:
ST-36TRB-IPI
PIER-36TRB-IPI
LCOR-36TRB-IPI
RCOR-36TRB-IPI
NOTICE
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow • Leave this manual with
and maintenance these instructions for safe
party responsible for use
instructions included. installation and operation.
and operation.
WARNING
WARNING: If the information in these
HOT SURFACES!
instructions is not followed exactly, a fi re
Glass and other surf
ملخص المحتوى في الصفحة رقم 2
Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. This owner’s manual should be retained for future A. Congratulations reference. We suggest that you keep it with your other Congratulations on selecting a Heat & Glo gas fi replace, an important documents and product manuals. elegant and clean alternative to wood burning fi replaces. The information contained in this owner’s manual, unless The Heat & Glo gas fi replace you h
ملخص المحتوى في الصفحة رقم 3
Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury. • WARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury. • CAUTION! Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury. • NOTICE: Used to address practices not related to personal injury. Table of Contents A. Congratulations . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ملخص المحتوى في الصفحة رقم 4
12 Electrical Information A. Wiring Requirements . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52 B. Intellifi re Ignition System Wiring . . . . . . . . . . . . . . . . . . . . 52 C. Optional Accessories Requirements . . . . . . . . . . . . . . . . 52 D. Electrical Service and Repair . . . . . . . . . . . . . . . . . . . . . . 52 E. Junction Box Installation. . . . . . . . . . . . . . . . . . . . . . . . . . 54 F. Wall Switch Installation for Fan (Optional) . . . . . . . . . . . . 54
ملخص المحتوى في الصفحة رقم 5
B. Limited Lifetime Warranty Hearth & Home Technologies LIMITED WARRANTY Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood, pellet and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or Canada. Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts. Warranty Period HHT Manufactured Appliances and Venting Components Covere
ملخص المحتوى في الصفحة رقم 6
B. Limited Lifetime Warranty (continued) • This limited warranty does not extend to or include surface fi nish on the appliance or terminations, door gasketing, glass gasketing, glass discoloration, fi rebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or corrosion on any of the metal surfaces, cast iron components, baffl es, fi repots, doors, or fi rebox area are not covered by this warranty. • Noise resulting from minor expansion, contraction, or movement of certain p
ملخص المحتوى في الصفحة رقم 7
Listing and Code Approvals 1 1 A. Appliance Certifi cation C. BTU Specifi cations Maximum Minimum Orifi ce MODELS: ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, Models Input Input Size RCOR-36TRB-IPI (U.S. or Canada) BTU/h BTU/h (DMS) LABORATORY: Underwriters Laboratories, Inc. (UL) US ST-36TRB-IPI 37,000 26,000 32 (0-2000 FT) PIER-36TRB-IPI TYPE: Direct Vent Gas Appliance Heater LCOR-36TRB-IPI CANADA 34,500 23,900 33 RCOR-36TRB-IPI (2000-4500 FT) STANDARD: ANSI Z21.88-2007 • CSA 2.33a-2007 D
ملخص المحتوى في الصفحة رقم 8
Inspection Note: The following requirements reference various The state or local gas inspector of the side wall horizon- Massachusetts and national codes not contained in this tally vented gas fueled equipment shall not approve the document. installation unless, upon inspection, the inspector ob- serves carbon monoxide detectors and signage installed H. Requirements for the Commonwealth of in accordance with the provisions of 248 CMR 5.08(2)(a)1 Massachusetts through 4. For all side wall
ملخص المحتوى في الصفحة رقم 9
User Guide Operating Instructions 2 2 • Keep remote controls out of reach of children. A. Gas Fireplace Safety • Never leave children alone near a hot fi replace, whether operating or cooling down. WARNING • Teach children to NEVER touch the fi replace. HOT SURFACES! Glass and other surfaces are hot during • Consider not using the fi replace when children will be operation AND cool down. present. Hot glass will cause burns. Contact your dealer for more information, or visit: www. • DO NOT to
ملخص المحتوى في الصفحة رقم 10
CLEAR SPACE 3 FT. IN FRONT OF FIREPLACE C. Fan Kit (optional) F. Fixed Glass Assembly If desired, a fan kit may be added. Contact your dealer to See Section 14.G. order the correct fan kit. G. Remote Controls, Wall Controls and Wall D. Clear Space Switches WARNING! DO NOT place combustible objects in front Follow the instructions supplied with the control installed of the fi replace or block louvers. High temperatures may to operate your fi replace: start a fi re. See Figure 2.2. For safety:
ملخص المحتوى في الصفحة رقم 11
I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. When using batteries, unplug the transformer. To prolong battery life, remove them when using the transformer. FOR YOUR SAFETY LIGHTING READ BEFORE LIGHTING INSTRUCTIONS (IPI) WARNING: If you do not follow these instructions exactly, a fi re or explosion may result causing property damage, personal injury or loss of life. 1. Turn off all electric power to the appliance. • Immediately call your gas supplie
ملخص المحتوى في الصفحة رقم 12
J. After Fireplace is Lit Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • Turn the fi replace off and allow it to completely cool. • Remove fi xed glass assembly. See Section 14.G. • Clean fi xed glass assembly. See Section 3. • Replace the fi xed glass assembly and run continuously on high an additional 12 hours. This cures the materials used to manufacture the fi re- place. NOTICE! Open windows for air circulation during fi re- place break-in. •
ملخص المحتوى في الصفحة رقم 13
Maintenance and Service 3 3 Doors, Surrounds, Fronts Any safety screen or guard removed for servicing must be replaced prior to operating the fi replace. Frequency: Annually By: Homeowner When properly maintained, your fi replace will give you many years of trouble-free service. We recommend an- Tools needed: Protective gloves, stable work surface nual service by a qualifi ed service technician. • Assess condition of screen and replace as necessary. A. Maintenance Tasks-Homeowner • Ins
ملخص المحتوى في الصفحة رقم 14
Venting Logs Frequency: Seasonally Frequency: Annually By: Homeowner By: Qualifi ed Service Technician Tools needed: Protective gloves and safety glasses. Tools needed: Protective gloves. • Inspect venting and termination cap for blockage or • Inspect for damaged or missing logs. Replace as necessary. obstruction such plants, bird nests, leaves, snow, debris, Refer to Section 14 for log placement instructions. etc. • Verify correct log placement and no fl ame impingement • Verify terminatio
ملخص المحتوى في الصفحة رقم 15
Burner Ignition and Operation Frequency: Annually By: Qualifi ed Service Technician Tools needed: Protective gloves, vacuum cleaner, whisk broom, fl ashlight, voltmeter, indexed drill bit set, and a manometer. • Verify burner is properly secured and aligned with pilot or igniter. • Clean off burner top, inspect for plugged ports, corrosion or deterioration. Replace burner if necessary. • Replace ember materials with new dime-size pieces. DO NOT block ports or obstruct lighting paths. Refer
ملخص المحتوى في الصفحة رقم 16
Installer Guide Getting Started 4 4 A. Typical Appliance System NOTICE: Illustrations and photos refl ect typical installations and are for design purposes only. Illustrations/diagrams are not drawn to scale. Actual product may vary from pictures in manual HORIZONTAL NON-COMBUSTIBLE ROOF FLASHING TERMINATION CAP MAINTAINS MINIMUM CLEARANCE (SECTION 10.G ) AROUND PIPE (SECTION 10.D) VERTICAL TERMINATION CAP (SECTION 10.E) STORM COLLAR (SECTION 10.H) VENT PIPE PENETRATES ROOF PREFERABLY W
ملخص المحتوى في الصفحة رقم 17
B. Design and Installation Considerations D. Inspect Appliance and Components Heat & Glo direct vent gas appliances are designed to • Carefully remove the appliance and components from operate with all combustion air siphoned from outside of the packaging. the building and all exhaust gases expelled to the outside. • The vent system components and decorative doors and No additional outside air source is required. fronts may be shipped in separate packages. Installation MUST comply with loca
ملخص المحتوى في الصفحة رقم 18
Framing and Clearances 5 5 NOTICE: Illustrations refl ect typical installations and are A. Selecting Appliance Location FOR DESIGN PURPOSES ONLY. Illustrations/diagrams When selecting a location for the appliance it is important to are not drawn to scale. Actual installation may vary due to consider the required clearances to walls (see Figure 5.1). individual design preference. WARNING! Risk of Fire or Burns! Provide adequate clearance around air openings and for service access. Due to
ملخص المحتوى في الصفحة رقم 19
To further prevent drafts, the wall shield and ceiling fi re- B. Constructing the Appliance Chase stops should be caulked with high temperature caulk to A chase is a vertical box-like structure built to enclose the seal gaps. Gas line holes and other openings should be gas appliance and/or its vent system. In cooler climates caulked with high temp caulk or stuffed with unfaced in- the vent should enclosed inside the chase. sulation. If the appliance is being installed on a cement NOTICE: Tre
ملخص المحتوى في الصفحة رقم 20
A E I I H C B G D F AB C D E F G H I DVP Pipe SLP Pipe DVP Pipe* Rough Rough PIER-36TRB-IPI Clearance Combustible Combustible Ends of Sides of Rough Rough Rough Opening Opening to Ceiling Floor Flooring Appliance Appliance Opening Opening Opening (Height) (Width) (Width) (Width) (Depth) Inches 10 8-5/8 38-1/8 23 40 31-5/8 0 0 1/2 36 Millimeters 254 219 968 584 1016 803 0 0 13 914 * Adjust framing dimensions for interior sheathing (such as sheetrock) Figure 5.3 Clearances to Combustibles PIE