ملخص المحتوى في الصفحة رقم 1
DO NOT
DISCARD
R
Owner’s Manual
Installation and Operation
Model(s):
QVI-30FB-S
CAUTION
DO NOT DISCARD THIS MANUAL
• Important operating • Read, understand and follow
• Leave this manual with
and maintenance these instructions for safe party responsible for use
instructions included. installation and operation. and operation.
WARNING
WARNING: If the information in these
instructions is not followed exactly, a fi re HOT SURFACES!
Glass and other surfaces are hot during
or explosion may resul
ملخص المحتوى في الصفحة رقم 2
Read this manual before installing or operating this appliance. Please retain this owner’s manual for future reference. Congratulations Congratulations on selecting a Quadra-Fire gas appliance This Owner’s Manual should be retained for future —an elegant and clean alternative to wood burning reference. We suggest that you keep it with your other important documents and product manuals. appliances. The Quadra-Fire gas appliance you have selected is designed to provide the utmost in safety, T
ملخص المحتوى في الصفحة رقم 3
Table of Contents 1 Listing and Code Approvals 8 Gas Information A. Appliance Certifi cation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 A. Fuel Conversions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 B. BTU Specifi cations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 B. Gas Pressures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 C. High Altitude Installations . . . . . . . . . . . . . . . . . . . . . . . . . . 4 C. Ga
ملخص المحتوى في الصفحة رقم 4
Listing and Code Approvals 1 1 A. Appliance Certifi cation C. High Altitude Installations U.L. Listed gas appliances are tested and approved with- MODELS: QVI-30FB-S out requiring changes for elevations from 0 to 2000 feet in the U.S.A. and Canada. LABORATORY: Underwriters Laboratories, Inc. (UL) TYPE: Vented Gas Appliance Heaters When installing this appliance at an elevation above 2000 feet, it may be necessary to decrease the input rat- STANDARD: ANSI Z21.88-2002 • CSA2.33-2002 • UL307
ملخص المحتوى في الصفحة رقم 5
Getting Started 2 2 A. Design and Installation Considerations C. Inspect Appliance and Components Quadra-Fire direct vent gas appliances are designed to operate with all combustion air siphoned from outside of WARNING the building and all exhaust gases expelled to the outside. Inspect appliance and components for damage. No additional outside air source is required. Damaged parts may impair safe operation. • Do NOT install damaged components. CAUTION • Do NOT install incomplete component
ملخص المحتوى في الصفحة رقم 6
Fireplace Size Requirements 3 3 • The metal fl oor of the solid fuel fi rebox may be removed to A. Minimum Fireplace Opening facilitate the installation of the insert. The appliance may Minimum fi replace opening requirements are shown in not be placed directly on the base of the outer wrap, a 1/4 Figure 5.1. inch airspace must be provided between the insert and WARNING! Risk of Fire or Burns! Provide adequate the fl oor of the outer wrap. Use the levelling legs to raise clearance arou
ملخص المحتوى في الصفحة رقم 7
B. Clearances INLET AIR 12 in. MAX. WARNING EXHAUST VENT PIPE VENT PIPE Fire Risk. MANTEL Odor Risk. • Clearance to combustible material under the insert is 1/4 inch (0.6 cm). • Use leveling legs to raise insert minimum 1/4 inch above combustible material or outer wrap of factory built fi rebox. 12 in. MIN. WARNING MEASUREMENTS FROM Fire Risk. TOP EDGE OF UNIT • Locate and install appliance to all clearance specifi cations in manual. Figure 3.2 Clearances to Mantels or other Combustibles abov
ملخص المحتوى في الصفحة رقم 8
Termination Locations 4 4 A. Vent Termination Minimum Clearances WARNING Figure 4.1 specifi es minimum vent heights for various pitched roofs. Fire Risk. Asphyxiation Risk. • Terminations MUST meet minimum clearances. HORIZONTAL • Exhaust gases are hot. OVERHANG • Nearby vents may draw fumes into house. 2 FT. 20 INCHES MIN. VERTICAL MIN. WALL LOWEST DISCHARGE OPENING GAS DIRECT VENT TERMINATION CAP X 12 ROOF PITCH IS X/ 12 H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENI
ملخص المحتوى في الصفحة رقم 9
Vent Information and Diagrams 5 5 A. Vent Table Key WARNING The abbreviations listed in this vent table key are used in the vent diagrams. Fire Hazard. Explosion Risk. Symbol Description Asphyxiation Risk. V Minimum Vertical Run Length 14 ft. Do NOT connect this gas appliance to a MIN chimney fl ue serving a separate solid fuel or V Maximum Vertical Run Length 50 ft. MAX gas burning appliance. • May impair safe operation of this appliance B. Horizontal Venting or other appliances connecte
ملخص المحتوى في الصفحة رقم 10
Installation Preparation 6 6 Prepare the existing solid fuel masonry or factory built E. Fireplace Conversion Notice non-combustible fi rebox for installation. Permanently attach the label with the following warning to the inside lower back of the fi replace fi rebox into which A. Flue Damper the insert is being installed. Silicone may be required to Fully lock the solid fuel fi replace’s fl ue damper in the open properly secure the label. position, OR completely remove it. B. Chimney WARNIN
ملخص المحتوى في الصفحة رقم 11
Installing Vent Pipe and Appliance 7 7 A. Venting Components B. Connecting Vent Pipe Reference instructions in the termination kit. CAUTION • Install the 3-inch fl exible vent pipe(s) down through the chimney. Sharp Edges • Secure the exhaust fl exible vent pipe to the 3 foot section • Wear protective gloves and safety stainless steel flexible vent pipe using the factory- glasses during installation. installed 3-inch collar in the stainless steel section of pipe (see Figure 7.1). The verti
ملخص المحتوى في الصفحة رقم 12
CUT AND BEND WARNING FLASHING AS NEEDED TO FIT CHIMNEY Fire Risk. Only an approved Hearth & Home Technologies surround may be used to cover integral grills on solid fuel burning fi replaces. • No other components such as shrouds, sheet- SEALANT metal plates, etc., may be used to seal off vents. ADHESIVE WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury
ملخص المحتوى في الصفحة رقم 13
D. Installing Adaptor and Termination Cap CAUTION For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 7.3). Sharp Edges To install adaptor see Figure 7.4. • Wear protective gloves and safety glasses during installation. HORIZONTAL Damper Flashing Kit (Optional) OVERHANG For use with LINK-DV4-30B Liner Kit. 2 FT. Note: Damper may have to be removed to use this kit. 20 INCHES MIN. VERTICAL MIN. WALL • Run fl ex liners through 3” holes in damper fl
ملخص المحتوى في الصفحة رقم 14
Gas Information 8 8 A. Fuel Conversions C. Gas Connection Before making gas connections ensure that appliance be- Note: Have the gas supply line installed in accordance ing installed is compatible with the available gas type. with local building codes, if any. If not, follow ANSI Any natural or propane gas conversions necessary to 223.1. Installation should be done by a qualifi ed installer meet the appliance and locality needs must be made by approved and/or licensed as required by th
ملخص المحتوى في الصفحة رقم 15
HIGH ALTITUDE INSTALLATIONS WARNING U.L. Listed gas appliances are tested and approved without Fire or Explosion Hazard requiring changes for elevations from 0 to 2000 feet in the • Gas buildup during line purge may ignite. U.S.A. and Canada. • Purge should be performed by qualifi ed technician. When installing this appliance at an elevation above 2000 feet, • Ensure adequate ventilation. it may be necessary to decrease the input rating by changing • Ensure there are no ignition sources such
ملخص المحتوى في الصفحة رقم 16
Electrical Information 9 9 Appliance Requirements A. Wiring the Appliance • This appliance DOES NOT require 110-120 VAC to Note: Electrical wiring must be installed by a licensed operate. electrician. • It is recommended that a 110 VAC junction box be connected for use with fan or remote control. (See Figure Note: This appliance must be electrically wired and grounded 9.2 for junction box wiring). in accordance with local codes or, in the absence of local codes, with National Electric
ملخص المحتوى في الصفحة رقم 17
B. Junction Box Installation C. Installation for Fan (Optional) On units already installed removal of decorative front, INSERT STRAIN RELIEF surround and gas insert is required. AROUND CORD IN THIS END FROM OUTSIDE OF UNIT FEED PLUG • Detach fl exible liner from back of unit if insert is installed. THROUGH HOLE SIDEWALL • Remove the four screws on the cover plate (see Figure 9.3). JUNCTION BOX SCREW PROVIDED Figure 9.2 Junction box installation COVER FAN PLATE Optional Accessories Connecting
ملخص المحتوى في الصفحة رقم 18
VARIABLE SPEED CONTROL JUNCTION BOX BLK BLK BLOWER RECEPTACLE BLK BLK BLK BLK BLK WHT WHT BLK GROUND BLOWER TEMPERATURE GRN SENSOR SWITCH BLK WHT 110-120 VAC FAN JUNCTION BOX NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, TEMPERATURE SENSOR SWITCH IT MUST BE REPLACED WITH TYPE 0 105 C RATED WIRE. SPEED CONTROL (RHEOSTAT) BEND GROUND WIRE UP TABS (ATTACH TO ANY METAL SURFACE) Figure 9.4 Fan Wiring Diagram 18 Quadra-Fire • QVI-30FB-S • 2020-910 Rev. F
ملخص المحتوى في الصفحة رقم 19
Finishing 1 10 0 A. Mantel Projections LOCATING TABS Figure 10.1 shows the minimum vertical and corresponding maximum horizontal dimensions of appliance mantels or other combustible projections above the top front edge of the appliance, not the surround. INLET AIR 12 in. MAX. FIREBOX EXHAUST VENT PIPE VENT PIPE MANTEL 12 in. MIN. LOCATING SLOTS MEASUREMENTS FROM TOP EDGE OF UNIT Figure 10.1 Clearances to Mantels or other Combustibles above Appliance B. Installing Trim Surrounds Figure 1
ملخص المحتوى في الصفحة رقم 20
Appliance Setup 11 11 A. Remove Shipping Materials Placing the Ember Material Ember material is shipped with this gas appliance. To place Remove shipping materials from inside or underneath the the ember material: fi rebox. • Embers CANNOT be placed directly over ports. B. Clean the Appliance • When placing Glowing Embers® onto the burner care should be taken so that the ports are not covered. Place Clean/vacuum any sawdust that may have accumulated the dime-size ember pieces near port h