ملخص المحتوى في الصفحة رقم 1
Ventless Fireplace
Models: UVDR36C
UVDR42C
INSTALLER/CONSUMER
SAFETY INFORMATION
Read and save
these instructions.
This book contains your installation instruc-
tions and should be kept in a safe place. For
you to realize all the advantages and use of
the reliable service that has been engineered
into your CFM Corporation fireplace, you
must carefully follow all of the instructions
contained in this book regarding installation
and operation of the fireplace.
These instructions should be r
ملخص المحتوى في الصفحة رقم 2
UVDR Series Unvented Gas Fireplaces Table of Contents Hearth Dimensions ........................................................................................................................2 Fireplace Dimensions ..................................................................................................................3 Installation Instructions ...............................................................................................................4 Locating the Fireplace ....
ملخص المحتوى في الصفحة رقم 3
UVDR Series Unvented Gas Fireplaces Fireplace Dimensions P Rough K Opening Depth L N H P 1/2” Clearance to Rough Opening Width C M Combustibles not Required at this Point Rough Opening Height 1/2” Clear- F E E ance to B Combustibles A not Required at this Point J D 6���" Gas Line C G Access Fig. 1a UVDR36/42C specifications and framing dimensions. UVDR36C UVDR42C A 36” 42” B 21 ⁷⁄₈” 21 ⁷⁄₈” C 39” 45” 78984 ADF36/42C D 7” 8” SPECS E 35” 39” 2/04 F 38 ¹⁄₄” 42 ¹⁄₄” G 9” 10 ¹⁄₂” H
ملخص المحتوى في الصفحة رقم 4
UVDR Series Unvented Gas Fireplaces Installation Instructions If the fireplace is to be installed on a raised wooden Locating the Fireplace platform, the platform must be a continuous level sur- Figure 2 shows some of the many ways your fireplace face. The fireplace must be secured in place so it can- may be installed. Consider the traffic pattern in your not shift positions. The nailing flanges on the sides of room and the location of doors and windows. Moving the firebox make securing it to the
ملخص المحتوى في الصفحة رقم 5
UVDR Series Unvented Gas Fireplaces Clearance to Combustible Clearance to Combustible Mantel Projections with 4” Mantel Projections without 3a 3c 3d Canopy Canopy 42" 24 22 22 20 20 18 5" Min. Combustible Per- 18 16 pendicular Wall 16 14 3b 14 12 10" 12 10 Clearances 10 8 without Canopy 6" 8 6 24" 2 4 6 8 10 Min. 2 4 6 8 10 Noncombustible Mantel (Combustible) Material 16" *Combustible Projections Projections (“) Min. above the fireplace must be within the area described by the 9 ���" da
ملخص المحتوى في الصفحة رقم 6
UVDR Series Unvented Gas Fireplaces The normal gas connection is 1/2” NPT, made at the left D 1/2" side facing the unit. If a right side connection is desired, the connecting pipe must be led at the rear of the fire- place to terminate at the left hand side for connection to C the fireplace. Noncombustible Insulation 5" A 1/2” Clearance not Required at Side Refractory This Point 1" Min. Refractory Cement Fireplace Outer Wrap 1/2” Gas Pipe T227 Fig. 6 Gas line installation. T227 Piping sho
ملخص المحتوى في الصفحة رقم 7
UVDR Series Unvented Gas Fireplaces Finishing Material Hearth Extension A hearth extension may be used but is not required for Stud these fireboxes. Noncombustible Material Insulation A raised hearth extension may be used as shown in Caulking or Sealant Figure 8. Hearth Brick Seal with Noncom- Side View bustible Material 1/2" Hearth Extension Stand- Noncombustible off Insulation Finishing Material Combustibles Al- Surround lowed Top View Caulking or Sealant (no carpet or vinyl) FP568 Combusti
ملخص المحتوى في الصفحة رقم 8
UVDR Series Unvented Gas Fireplaces Step 2: The SCVS - Variable Speed Control Kit (or Blower Installation standard wall switch) should be installed before the BEFORE YOU BEGIN...A FEW BASIC RULES blower assembly installation. Please refer to instruc- 1. Check to ensure that electrical service has been tions found in the SCVS Kit. provided to the junction box located in the bottom Step 3: Remove the metal hearth cover and the bot- chamber of the firebox. tom two right brick panels from the fir
ملخص المحتوى في الصفحة رقم 9
UVDR Series Unvented Gas Fireplaces should be caulked around its perimeter to assure a Install Optional Outside Air Kit tight seal. The rain cap opening should be positioned The AKU3 Outside Air Kit can be installed to bring com- downward. (Fig. 15) bustion air to the heated room air. The air that is drawn The Outside Air Kit is now installed and ready for use. into the heated room air from outside the home or un- heated area helps relieve the pressure in the home. The duct termination shoul
ملخص المحتوى في الصفحة رقم 10
UVDR Series Unvented Gas Fireplaces Operating Precautions and Instructions Operation is automatic. A slight negative pressure inside the house will open the barometric flapper valve. Periodically inspect the duct termination for any block- age. Correct if necessary. KT145 Fig. 14 Secure the inlet collar assembly. KT145 Duct Ter- Caulking AKU reinstall mination cover plate 9/6/00 djt Rain Cap Wall FP1061 Fig. 15 Caulk and install duct termination/rain cap in place. FP1061 AKMST rain cap 7/6/
ملخص المحتوى في الصفحة رقم 11
UVDR Series Unvented Gas Fireplaces 6 7 5 2 1 3 8 4 9 12 10 13 11 14 7469 CFM Corporation reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. UVDR36/42C Series Unvented Fireplaces 7469 Description UVDR36C UVDR42C UVDR36/42C parts 1. Firescreen Rod (2 per fireplace) 68403 65864 8/04 2. Firescreeen w/Rings (2 per fireplace) 66146 62197 3. Screen Retainer (4 per fireplace) 62222 62222 4. Black Canopy 687
ملخص المحتوى في الصفحة رقم 12
UVDR Series Unvented Gas Fireplaces Accessories Decorative Surrounds SPB36 SPB42 Blower Kit BL-4 or FK12 (Junction box is provided with fireplace) Variable Speed Control SCVS Heat Reducing Canopy UC36PB (UVDR36C) Polished Brass UC42PB (UVDR42C) Polished Brass Brick Canopy BC36L (UVDR36C) BC42L (UVDR42C) Outside Air Kit AKU3 Contact CFM Corporation for questions concerning Servicing prices and policies covering replacement parts. Parts Repair and replacement work sh
ملخص المحتوى في الصفحة رقم 13
UVDR Series Unvented Gas Fireplaces 20007469 13
ملخص المحتوى في الصفحة رقم 14
UVDR Series Unvented Gas Fireplaces 14 20007469
ملخص المحتوى في الصفحة رقم 15
UVDR Series Unvented Gas Fireplaces LIMITED LIFETIME WARRANTY PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner. BASIC WARRANTY • Any part and/or component replaced under the provisions of this warranty is covered for six months or the remainder of the original CFM Corporation (hereinafter referred to collectively a
ملخص المحتوى في الصفحة رقم 16
CFM Corporation 410 Admiral Blvd. • Mississauga, Ontario, Canada L5T 2N6 800-668-5323 • www.cfmcorp.com