ملخص المحتوى في الصفحة رقم 1
246750-YTG-L-0408
DESCRIPTION
The YZE Series unit is the outdoor part of a versatile heat pump
system. It is designed to be custom matched with one of our
complete line of evaporator sections, each designed to serve a
specific function. Matching air handlers are available for upflow,
downflow, and horizontal left or right application to provide a
complete system. Electric heaters are available if required. Add-
on coils are available for use with upflow, downflow, or horizontal
furnaces. Field i
ملخص المحتوى في الصفحة رقم 2
246750-YTG-L-0408 Physical and Electrical Data MODEL YZE02411 YZE03611 YZE04811 YZE06011 Unit Supply Voltage 208-230V, 1 φ, 60Hz 1 187 to 252 Normal Voltage Range Minimum Circuit Ampacity 18.6 24.7 27.9 37.9 2 30 40 45 60 Max. Overcurrent Device Amps 3 20 25 30 40 Min. Overcurrent Device Amps Multi-stage Compressor Yes Yes Yes Yes Compressor Type Scroll Scroll Scroll Scroll Rated Load 13.7 18.6 21.2 29.2 Compressor Amps Locked Rotor 52 82 96 118 Crankcase Heater No No No No Fan Motor Amps Ra
ملخص المحتوى في الصفحة رقم 3
246750-YTG-L-0408 Additional R-410A Charge / TXV Size for Various Matched Systems Outdoor Unit YZE02411 YZE03611 YZE04811 YZE06011 1TVM902 1 1TVM902 1TVM905 1TVM906 Approved System Thermal Expansion Valve 1TVM4A1 Factory R-410A Charge, lbs-oz 8 - 14 8 - 8 14 - 8 14 - 0 2 3 Indoor Coil TXV Kit - Additional Charge, Oz FC/MC/PC/UC30A + 4 – – – FC/MC/PC/UC30B + 4 – – – FC/MC/PC32A + 6 – – – FC/MC/PC35B + 6 + 0 – – FC/MC/PC35C + 6 + 0 – – FC/MC/PC/UC36A + 5 – – – FC/MC/PC/UC36B + 5 – – – FC/MC/PC36C
ملخص المحتوى في الصفحة رقم 4
246750-YTG-L-0408 COOLING CAPACITY - With Air Handler Coils AIR HANDLER COOLING 1 COIL UNIT MODEL RATED NET SENSIBL MODEL MODEL W STAGE SEER EER CFM MBH E 1 535 18.6 13.6 13.00 AV24 17 – 15.00 2 800 24.0 18.6 12.50 1 535 18.6 13.6 13.00 AV36 17 – 15.00 2 800 24.0 18.6 12.50 1 620 18.6 13.6 12.00 MV12B 17 FC/MC30B 14.25 2 800 24.0 18.6 11.50 1 650 18.1 14.4 12.15 MV12B 17 FC/MC35B 15.00 2 775 24.0 19.6 12.00 YZE02411 1 650 18.6 13.6 13.00 MV16C 21 FC/MC35C 15.00 2 775 24.0 18.6 12.5
ملخص المحتوى في الصفحة رقم 5
246750-YTG-L-0408 COOLING CAPACITY - With Variable Speed Furnaces COOLING VARIABLE SPEED COIL UNIT MODEL W NET MBH 1 RATED FURNACE MODEL MODEL STAGE SEER EER CFM TOTAL SENSIBLE 1 430 17.3 11.5 12.60 PV8*A12 FC/MC/PC/UC30A 14 14.00 2 750 23.0 18.2 12.00 1 625 18.5 14.4 12.35 PV9*A12 FC/MC/PC30A 14 14.25 2 800 23.6 19.0 12.00 1 425 17.5 12.5 12.60 P(C,V)9*B12 FC/MC/PC/UC30B 17 14.25 2 800 23.6 19.0 12.00 1 425 17.4 11.6 12.00 PV9*A12 FC/MC/PC32A 14 14.75 2 800 24.0 19.0 11.50 1 430 17
ملخص المحتوى في الصفحة رقم 6
246750-YTG-L-0408 COOLING CAPACITY - With Variable Speed Furnaces (Continued) COOLING VARIABLE SPEED COIL UNIT MODEL W NET MBH 1 RATED FURNACE MODEL MODEL STAGE SEER EER CFM TOTAL SENSIBLE 1 640 24.2 16.2 12.70 P(C,V)9*C16 FC/MC/PC/UC48C 21 15.50 2 1200 35.2 25.1 12.00 1 780 25.0 18.9 12.85 PV8*C16 FC/MC/PC/UC48C 21 15.00 2 1200 34.8 26.8 12.00 1 800 25.2 19.1 12.90 PV8*C20 FC/MC/PC/UC48C 21 15.25 2 1200 35.0 26.8 12.00 YZE03611 1 770 25.0 18.8 12.85 P(C,V)9*D20 FC/MC/PC/UC48D 24 15.5
ملخص المحتوى في الصفحة رقم 7
246750-YTG-L-0408 HEATING CAPACITY - With Air Handler Coils HEATING 1 AIR HANDLER COIL UNIT MODEL NET MBH RATED MODEL MODEL STAGE HSPF COP @ 47 CFM 47 OD 17 OD 1 650 19.0 - - 3.30 AV24 - 2 775 24.0 15.6 8.25 3.36 2 650 23.2 14.6 8.05 3.12 1 650 19.0 - - 3.30 AV36 - 2 775 24.0 15.6 8.25 3.36 2 650 23.2 14.6 8.05 3.12 1 620 19.0 - - 3.30 MV12B FC/MC30B 2 800 24.0 15.6 8.10 3.36 2 620 23.2 14.6 8.00 3.12 1 620 19.0 - - 3.30 MV12B FC/MC35B 2 800 24.0 15.6 8.30 3.36 2 620 23.2 14.6 8.05 3
ملخص المحتوى في الصفحة رقم 8
246750-YTG-L-0408 HEATING CAPACITY - With Air Handler Coils (Continued) HEATING 1 AIR HANDLER COIL UNIT MODEL NET MBH RATED MODEL MODEL STAGE HSPF COP @ 47 CFM 47 OD 17 OD 1 1200 37.6 - - 3.26 AV60 - 2 1900 55.0 32.4 8.05 3.50 2 1200 50.0 29.8 7.90 3.22 1 1200 37.6 - - 3.26 F2FV060 - 2 1900 54.0 32.2 8.00 3.50 2 1200 50.0 29.8 7.90 3.22 YZE06011 1 1200 37.6 - - 3.26 MV20D FC/MC60D 2 1900 54.5 32.4 8.00 3.50 2 1200 50.0 30 7.90 3.22 1 1175 37.6 - - 3.26 MV20D FC/MC62D 2 1800 54.5 32.6
ملخص المحتوى في الصفحة رقم 9
246750-YTG-L-0408 HEATING CAPACITY - With Variable Speed Furnaces (Continued) HEATING VARIABLE SPEED COIL UNIT MODEL W RATED NET MBH COP @ 1 FURNACE MODEL MODEL STAGE HSPF CFM 47 47 OD 17 OD 1 650 23.0 - - 3.54 P(C,V)9*B12 FC/MC/PC35B 17 2 1200 33.0 20.8 8.50 3.70 2 650 29.4 19.6 8.35 3.30 1 650 23.0 - - 3.54 PV8*B16 FC/MC/PC35B 17 2 1200 33.0 21.0 8.50 3.70 2 650 29.4 19.6 8.35 3.30 1 650 23.0 - - 3.54 P(C,V)9*C16 FC/MC/PC35C 21 2 1200 33.0 21.0 8.50 3.70 2 650 29.4 19.6 8.35 3.30 1 6
ملخص المحتوى في الصفحة رقم 10
246750-YTG-L-0408 HEATING CAPACITY - With Variable Speed Furnaces (Continued) HEATING VARIABLE SPEED COIL UNIT MODEL W NET MBH 1 RATED COP @ FURNACE MODEL MODEL STAGE HSPF CFM 47 OD 17 OD 47 1 860 31.2 - - 3.56 PV8*C20 FC/PC/UC60C 21 2 1610 48.0 27.8 8.35 3.96 2 860 44.5 26.2 8.30 3.66 1 870 31.2 - - 3.56 P(C,V)9*C20 FC/PC/UC60C 21 2 1590 48.0 27.8 8.40 3.96 2 870 44.5 26.2 8.30 3.66 1 855 31.2 - - 3.56 P(C,V)9*D20 FC/MC/PC/UC60D 24 2 1620 48.0 27.8 8.40 3.96 2 855 44.5 26.2 8.30 3.66
ملخص المحتوى في الصفحة رقم 11
246750-YTG-L-0408 ACCESSORIES* SOUND POWER RATINGS* (dBA) TXV Kits - 1TVM9 series thermal expansion valves precisely UNIT MODEL Cooling Heating meter refrigerant for optimum performance. 024 71 72 Bonnet Sensor (2SB13700124) - The bonnet sensor is used 036 72 73 to sense plenum temperature, and is optional with a gas or oil 048 72 73 back-up heat source. Compatible only with 13 SEER and 060 73 74 higher heat pumps. * Rated in accordance with ARI 270-95 Standards. Dehumidistat (2HU16700124) - Pr
ملخص المحتوى في الصفحة رقم 12
246750-YTG-L-0408 COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZE02411 INDOOR COIL MODEL NO. FC/MC36B + MV12B ID CFM 550 600 650 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57 T.C. 19.5 30.3 25.6 25.2 19.8 20.4 31.2 26.6 26.2 20.0 21.4 32.2 27.6 27.1 20.3 65 S.C. 18.0 3.2 3.2 3.3 3.3 18.8 3.3 3.2 3.3 3.3 19.7 3.3 3.2 3.3 3.3 K.W. 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1.0 1
ملخص المحتوى في الصفحة رقم 13
246750-YTG-L-0408 COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZE02411 INDOOR COIL MODEL NO. FC/MC36B + MV12B ID CFM 700 800 900 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57 T.C. 23.9 24.9 23.7 27.3 29.1 25.2 25.8 24.6 28.0 30.0 26.5 26.7 25.4 28.8 30.9 65 S.C. 22.6 21.7 18.0 18.9 14.6 23.8 23.1 19.5 20.3 15.7 24.9 24.5 21.0 21.6 16.8 K.W. 1.4 1.4 1.4 1.4 1.4
ملخص المحتوى في الصفحة رقم 14
246750-YTG-L-0408 COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZE03611 INDOOR COIL MODEL NO. FC/MC48C + MV16C ID CFM 750 800 850 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57 T.C. 24.3 26.1 25.5 28.1 31.9 24.8 26.4 25.9 28.5 32.2 25.3 26.6 26.3 28.8 32.5 65 S.C. 23.9 22.4 18.5 19.1 15.6 24.4 22.8 19.1 19.5 16.2 24.9 23.2 19.7 19.9 16.8 K.W. 1.3 1.3 1.3 1.3 1.2 1
ملخص المحتوى في الصفحة رقم 15
246750-YTG-L-0408 COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZE03611 INDOOR COIL MODEL NO. FC/MC48C + MV16C ID CFM 1100 1200 1300 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57 T.C. 31.6 36.2 37.2 37.3 38.5 33.1 36.3 37.6 37.4 38.3 34.7 36.5 37.9 37.6 38.1 65 S.C. 31.2 30.3 26.6 24.5 19.1 32.9 31.3 27.6 24.9 19.3 34.5 32.3 28.5 25.4 19.5 K.W. 1.9 2.0 2.1 2.0 2
ملخص المحتوى في الصفحة رقم 16
246750-YTG-L-0408 COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZE04811 INDOOR COIL MODEL NO. FC/MC60D + MV20D ID CFM 950 1000 1050 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57 T.C. 31.6 34.3 34.2 39.4 44.4 31.9 34.5 34.8 40.0 44.9 32.3 34.8 35.4 40.6 45.4 65 S.C. 31.6 29.3 24.7 25.3 20.9 31.9 29.9 25.4 26.0 21.3 32.3 30.5 26.2 26.8 21.7 K.W. 1.6 1.6 1.6 1.6 1.6
ملخص المحتوى في الصفحة رقم 17
246750-YTG-L-0408 COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZE04811 INDOOR COIL MODEL NO. FC/MC60D + MV20D ID CFM 1500 1600 1700 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57 T.C. 42.6 46.0 47.1 52.2 59.2 43.3 46.5 47.6 52.8 59.5 44.0 46.9 48.0 53.4 59.7 65 S.C. 43.5 41.8 35.9 36.2 29.0 44.2 42.9 37.0 37.3 29.6 44.9 44.0 38.0 38.4 30.2 K.W. 2.6 2.6 2.6 2.7 2
ملخص المحتوى في الصفحة رقم 18
246750-YTG-L-0408 COOLING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZE06011 INDOOR COIL MODEL NO. MC61D + MV20D ID CFM 1100 1150 1200 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57 T.C. 37.0 39.7 40.4 44.5 49.2 37.7 40.2 40.9 44.9 49.8 38.4 40.8 41.4 45.2 50.3 65 S.C. 37.9 34.8 29.7 29.4 24.3 38.6 36.1 30.4 30.1 23.9 39.2 37.3 31.1 30.7 23.6 K.W. 2.1 2.1 2.1 2.1 2.1 2
ملخص المحتوى في الصفحة رقم 19
246750-YTG-L-0408 COOLING PERFORMANCE DATA - HIGH CFM 2-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZE06011 INDOOR COIL MODEL NO. MC61D + MV20D ID CFM 1600 1800 2000 CONDENSER ENTERING AIR ID DB (°F) 80 80 75 80 80 80 80 75 80 80 80 80 75 80 80 TEMPERATURE ID WB (°F) 57 62 62 67 72 57 62 62 67 57 62 62 67 72 57 T.C. 53.2 56.9 56.8 59.8 61.0 54.1 57.0 57.4 59.5 60.9 55.0 57.1 58.0 59.2 60.7 65 S.C. 53.6 50.4 42.0 41.8 29.6 54.6 51.9 43.0 41.7 29.8 55.6 53.4 44.0 41.5 30.1 K.W. 3.5 3.6 3.5 3.6 3.6
ملخص المحتوى في الصفحة رقم 20
246750-YTG-L-0408 HEATING PERFORMANCE DATA - LOW CFM 1-STAGE OPERATION OUTDOOR UNIT MODEL NO. YZE02411 INDOOR COIL MODEL NO. FC/MC/PC36B + MV12B AIR TEMP. AIR TEMP. ID CFM ENTERING ENTERING 550 600 650 OUTDOOR INDOOR MBTUH KW C.O.P. MBTUH KW C.O.P. MBTUH KW C.O.P. UNIT COIL 60 23.4 1.6 4.3 23.5 1.5 4.5 23.7 1.5 4.8 60 70 21.7 1.8 3.6 22.1 1.7 3.8 22.5 1.7 4.0 80 20.1 2.0 3.0 20.7 1.9 3.2 21.4 1.9 3.4 60 19.5 1.5 3.8 19.5 1.4 4.0 19.6 1.4 4.1 47 70 18.8 1.7 3.2 18.9 1.7 3.3 19.0 1.6 3.4 80