Features and Benefits ® • Climatuff compressor � Demand Defrost Control � All aluminum Spine Fin™ coil � Easy top & fan removal � DuraTuff™ base, fast complete drain, � R-22 refrigerant (Not Factory Supplied) weather proof � 100% line run test � Polyslate gray cabinet high gloss with � Low ambient cooling to 55°F as fan motor cover shipped � Quick-Sess™ cabinet, easy service � Low ambient cooling to 40°F with access and refrigerant connections EDC accessory AY28X084 with full coil protection � L
ملخص المحتوى في الصفحة رقم 3
Contents Features and Benefits 2 General Data 4 Product Specifications 4 A-weighted Sound Power Level [dB(A)] 4 Accessory Description and Usage 5 AHRI Standard Capacity Rating Conditions 5 Model Nomenclature 6 Electrical Data 7 Dimensions 9 Mechanical Specification Options 10 22-1771-04 3
ملخص المحتوى في الصفحة رقم 4
General Data Product Specifications Model No. 1 2TWB3018A1 2TWB3024A1 2TWB3030A1 2TWB3036A1 Electrical Data V/Ph/Hz 2 200/230/1/60 200/230/1/60 200/230/1/60 200/230/1/60 Min Cir Ampacity 8 12 13 19 Max Fuse Size (Amps) 15 20 20 30 ® ® ® ® Compressor CLIMATUFF CLIMATUFF CLIMATUFF CLIMATUFF RL Amps - LR Amps 5.9 - 38.6 8.7 - 57.8 9.5 - 63 14.1 - 90.8 Outdoor Fan FL Amps 0.6 1.3 0.9 1.4 Fan HP 1/15 1/4 1/8 1/6 Fan Dia (inches) 19.0 19.0 23.0 27.6 Coil Spine Fin™ Spine Fin™ Spine Fin™ Spine Fin™ Ref
ملخص المحتوى في الصفحة رقم 5
General Data Product Specifications Model No. 1 2TWB3042A1 2TWB3048A1 2TWB3060A1 Electrical Data V/Ph/Hz 2 200/230/1/60 200/230/1/60 208/230/1/60 Min Cir Ampacity 21 25 32 Max Fuse Size (Amps) 35 40 50 ® ® ® Compressor CLIMATUFF CLIMATUFF CLIMATUFF - SCROLL RL Amps - LR Amps 15.4 - 93.5 18.6 - 93.4 25.0 - 148 Outdoor Fan FL Amps 1.4 1.4 1.2 Fan HP 1/6 1/5 1/5 Fan Dia (inches) 27.6 27.6 27.6 Coil Spine Fin™ Spine Fin™ Spine Fin™ Refrigerant R-22 (Not Factory Supplied) 9/09-LB/OZ 9/09-LB/OZ 9/08-L
ملخص المحتوى في الصفحة رقم 6
Model Nomenclature 2 T W B 3 0 3 6 A1 000 AA TU D 1 B 0 8 0 A 9 H 3 1 A A High Efficiency Outdoor Units Furnaces Refrigerant Type Furnace Configuration TU = Upflow / Horizontal 2 = R-22 TD = Downflow / Horizontal 4 = R-410A Type TRANE D = 80% Premium Product Type X = 90% Premium W = Split Heat Pump Number of Heating Stages T = Split Cooling 1 = Single Stage 2 = Two Stage Product Family 3 = Three Stage Z = Leadership – Two Stage X = Leadership Cabinet Width A = 14.5" Cabinet Width R = Replaceme
ملخص المحتوى في الصفحة رقم 7
Electrical Data Schematic Diagrams (SEE LEGEND) 2TWB3018,024,030,036,042A 2TWB3048A Printed from D155595P01 Printed from D155596P01 22-1771-04 7
ملخص المحتوى في الصفحة رقم 8
Electrical Data Schematic Diagrams 2TWB3060A LEGEND SYMBOLS 8 22-1771-04
ملخص المحتوى في الصفحة رقم 9
Dimensions 2TWB3 Outline Drawing NOTE: ALL DIMENSIONS ARE IN MM (INCHES) MODELS BASE FIG. A B C D E F G H J K 2TWB3018A 2 2 832 (32-3/4) 724 (28-1/2) 651 (25-5/8) 5/8 1/4 127 (5) 57 (2-1/4) 181 (7-1/8) 44 (1-3/4) 457 (18) 2TWB3024A 2 1 832 (32-3/4) 724 (28-1/2) 651 (25-5/8) 3/4 5/16 137 (5-3/8) 65 (2-5/8) 210 (8-1/4) 57 (2-1/4) 457 (18) 2TWB3030A 3 1 933 (36-3/4) 829 (32-5/8) 756 (29-3/4) 3/4 5/16 143 (5-5/8) 92 (3-5/8) 210 (8-1/4) 79 (3-1/8) 508 (20) 2TWB3036A 4 1 943 (37-1/8) 946 (37-1/4) 870
ملخص المحتوى في الصفحة رقم 10
Mechanical Specification Options General Condenser Coil The 2TWB3 is designed to operate at The outdoor coil provides low airflow outdoor ambient temperatures as high resistance and efficient heat transfer. as 115°F. Cooling capacities are The coil is protected on all four sides matched with a wide selection of air by louvered panels. handlers and furnace coils that are AHRI Low Ambient Cooling certified. The unit is certified to UL 1995. As manufactured, this unit has a cooling Exterior is desi