ملخص المحتوى في الصفحة رقم 1
READ AND SAVE THESE INSTRUCTIONS
Model No.
CF755AB05
CF755SCB05
CF755AGW05
CF755ORB05
CF755AW05
CF755PB05
CF755BC05
CF755PW05
CF755BS05
CF755SCK05
CF755BQ05
CF755TG05
CF755BZH05
CF755WB05
DESIGNER CF755CK05
CF755WW05
CF755HTW05
Ceiling Fan
Net Weight: 18.0 Lbs.
Owner's Manual ENERGY STAR
LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the o
ملخص المحتوى في الصفحة رقم 2
WARNING ! WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of
ملخص المحتوى في الصفحة رقم 3
This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Installed Wire Length Wire Size A.W.G. Tools Needed for Assembly Up to 50 ft. 14 One Phillips head screwdriver One stepladder 50-100 ft. 12 One 1/4” blade screwdriver One wire stripper Three wire connectors (supplied). ! WARNING MATERIALS Before assembly your ceiling fan, refer to section on Wiring outlet box and box connectors must be of type proper method of wiring your fa
ملخص المحتوى في الصفحة رقم 4
3. Make sure the grommet is properly installed in the How to Put Your Ceiling coupling cover, then slide the coupling cover on Fan Together the downrod until it rests on the motor housing. Place the ceiling cover over the downrod. Be sure 1. Remove the hanger ball by loosening the setscrew that the ceiling cover and the coupling cover are in the hanger ball until the ball falls freely down the both oriented correctly (Figure 3). downrod (Figure 1). Remove the pin from the downrod, then remove th
ملخص المحتوى في الصفحة رقم 5
housing assembly with the holes in the plate. ! WARNING Secure the switch housing assembly by installing the three screws (Figure 6). To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, balancing the blades or cleaning the fan. Do not ! WARNING insert foreign objects in between rotating fan blades. To avoid possible fire or shock, do not pinch wires between the switch cup assembly and the switch 11. The blade flanges have an interlocking feature
ملخص المحتوى في الصفحة رقم 6
NOTE: CEILING COVER, How to Hang Your SUPPLY WIRES AND OUTLET FAN WIRES OMITTED BOX Ceiling Fan FOR CLARITY. ! WARNING The fan must be hung with at least 7' of clearance from floor to blades (Figure 9). HANGER BRACKET CEILING Figure 11 HANGER BALL/ DOWNROD ASSEMBLY How to Wire Your Ceiling Fan AT LEAST 7' If you feel that you do not have enough electrical wiring knowledge or experience, have your fan Figure 9 FLOOR installed by a licensed electrician. WARNING ! ! WARNING The outlet box and joist
ملخص المحتوى في الصفحة رقم 7
3. Screw the two threaded studs (supplied) into the Using Your Ceiling Fan tapped holes in the hanger bracket. 1. Restore electrical power to the outlet box by turning 4. Lift the ceiling cover up to the threaded studs and the electricity on at the main fuse box. turn until studs protrude through the holes in the 2. Check the operation of the fan by gently pulling on ceiling cover (Figure 13). the pull chain switch. 5. Secure the ceiling cover in place by sliding 3. All fans are shipped from the
ملخص المحتوى في الصفحة رقم 8
Maintenance Energy Efficient Use of Ceiling Fans IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Ceiling fan performance and energy savings rely Periodic cleaning of your new ceiling fan is the only heavily on the proper installation and use of the maintenance that is needed. ceiling fan. Here are a few tips to ensure quality and product performance. When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish. Choosing the Appropriate Mounting Location. Ceiling fans s
ملخص المحتوى في الصفحة رقم 9
WARNING: For your own safety, turn off power at fuse box or circuit breaker before trouble shooting your fan. ! Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, 2. Check line wire connections to fan and switch or loose switch wire connections in the wire connections in the switch housing. ! switch housing. WARNING: Make sure mai
ملخص المحتوى في الصفحة رقم 10
Repair Parts 2 1 3 15 5 4 16 17 20 7 6 9 19 12 13 14 11 8 10 18 10 U.L. Model No.: CF755
ملخص المحتوى في الصفحة رقم 11
Repair Parts Listing Model No. Key No. Description CF755AB05 CF755AGW05 CF755WB05 CF755BZH05 CF755PB05 CF755SCB05 CF755TG05 CF755BS05 CF755PW05 * Hanger Ball Assembly, 761655-3 761655-40 761655-20 761655-41 761655-2 761655-9 761655-13 761655-17 761655-22 Consisting of: 1 Hanger Bracket — — — — — — — — — 2 Hanger Ball — — — — — — — — — 3 Downrod — — — — — — — — — * Parts Bag Containing: 762997-1 762997-1 762997-1 762997-1 762997-4 762997-1 762997-1 762997-3 762997-1 4 Wire Connector (3) — — — — —
ملخص المحتوى في الصفحة رقم 12
Air Comfort Products DIVISION OF EMERSON ELECTRIC CO. 8100 W. Florissant • St. Louis, MO 63136 Part No. F40BP73170000 Printed in China 09/07 Form No. BP7317 U.L. Model No.: CF755