ملخص المحتوى في الصفحة رقم 1
READ AND SAVE THESE INSTRUCTIONS
®
™
DEVONSHIRE
Model No.
Damp Location
CF670OB00
52” Ceiling Fan
CF670CK00
Owner's Manual
CF670WB00
Net Weight: 22.8 Lbs.
CF670BQ00
LIMITED WARRANTY
What The Warranty Covers:
This warranty covers the motor and the other components and accessories of your Emerson ceiling fan against all defects in workmanship and materials.
You must be the original purchaser or user of the product to be covered.
What The Period Of Coverage Is:
As it applies to the motor, this war
ملخص المحتوى في الصفحة رقم 2
! WARNING WARNING: To avoid fire, shock, and serious personal injury, follow these instructions. Safety Instructions 1. Read your owner’s manual carefully and keep it for future reference. 2. Before servicing or cleaning unit, switch power off at service panel and lock service panel disconnecting means to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the service panel. 3. Be careful of
ملخص المحتوى في الصفحة رقم 3
This Manual Is Designed to Make it as Easy as Possible for You to Assemble, Install, Operate and Maintain Your Ceiling Fan Installed Wire Length Wire Size A.W.G. Tools Needed for Assembly Up to 50 ft. 14 One Phillips head screwdriver 50-100 ft. 12 One stepladder One wire stripper Two wire connectors (supplied) ! WARNING MATERIALS Before assembling your ceiling fan, refer to section on Wiring, outlet box and box connectors must be of type proper method of wiring your fan (page 5). If you feel req
ملخص المحتوى في الصفحة رقم 4
How to Put Your Ceiling Fan Together 1. Remove the hanger ball by loosening the setscrew 4. Make sure the grommet is properly installed in the in the hanger ball until the ball falls freely down the coupling cover, then slide the coupling cover on the downrod (Figure 1). Remove the pin from the downrod until it rests on the motor housing. Place downrod, then remove the hanger ball. Retain the the ceiling cover over the downrod. Be sure that pin and hanger ball for reinstallation in step 5. the c
ملخص المحتوى في الصفحة رقم 5
! WARNING SWITCH HOUSING ASSEMBLY SWITCH HOUSING CONNECTOR To reduce the risk of personal injury, do not bend the blade flange when installing the blade flanges, MOTOR CONNECTOR balancing the blades or cleaning the fan. Do not SWITCH HOUSING PLATE insert foreign objects in between rotating fan blades. RIB LINE (THIS SIDE UP) M5 x 6mm SLOTTED PHILLIPS WASHER HEAD SCREWS (3) Figure 7 12. Position the switch housing assembly on the switch housing plate and secure using three captive Phillips BLA
ملخص المحتوى في الصفحة رقم 6
NOTE: CEILING COVER, How to Hang SUPPLY WIRES AND OUTLET FAN WIRES OMITTED Your Ceiling Fan BOX FOR CLARITY. ! WARNING The fan must be hung with at least 7' of clearance HANGER from floor to blades (Figure 9). BRACKET HANGER BALL/ CEILING Figure 11 DOWNROD ASSEMBLY ! WARNING AT LEAST To avoid possible fire or shock, do not pinch wires 7' between the hanger ball/downrod assembly and hanger bracket. Figure 9 FLOOR ! WARNING How to Wire The outlet box and joist must be securely mounted Your Ceiling
ملخص المحتوى في الصفحة رقم 7
BLACK AND BLUE Using Your Ceiling Fan SUPPLY NOTE: CEILING COVER FAN WIRES GROUND OMITTED FOR CLARITY. WIRE 1. Restore electrical power to the outlet box by turning LISTED the electricity on at the main fuse box. WHITE SUPPLY WIRE (NEUTRAL) CONNECTOR (3) 2. Check the operation of the fan by gently pulling on the pull chain switch. 3. All fans are shipped from the factory with the reversing switch positioned to circulate air down- GREEN WIRE ward. If airflow is desired in opposite direction, turn
ملخص المحتوى في الصفحة رقم 8
! WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER BEFORE TROUBLE SHOOTING YOUR FAN. Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers. 2. Loose power line connections to the fan, or loose 2. Check line power connections to fan and switch wire switch wire connections in the switch housing. connections in the switch housing. ! WARNING: Make sure main