WARNING:
IF THE INFORMATION IN THESE INSTRUCTIONS
ARE NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
FOR YOUR SAFETY:
DO NOT STORE OR USE GASOLINE OR OTHER
FLAMMABLE VAPORS AND LIQUIDS IN THE VICIN-
ITY OF THIS OR ANY OTHER APPLIANCE.
INSTALLATION:
INSTALLATION AND SERVICE MUST BE PER-
FORMED BY A QUALIFIED INSTALLER, SERVICE
AGENCY OR LICENSED GAS SUPPLIER.
THIS PRODUCT MUST BE INSTALLED BY A
Jøtul GF 400 DV LICENSED PLUMBER OR G
ملخص المحتوى في الصفحة رقم 2
Welcome to Jøtul... Congratulations on the purchase of your new Jøtul GF 400 DV Sebago Gas Heater. We at Jøtul are glad you’ve made the decision to warm your hearth with a Jøtul product. Your new GF 400 DV Sebago benefits from our experience gained over 150 years as the world’s largest manufacturer of solid fuel burning appliances. We’ve been making fine quality cast iron wood and coal stoves and fireplaces continuously since 1853. In the Sebago, we’ve combined advanced gas technology with the w
ملخص المحتوى في الصفحة رقم 3
Jøtul GF 400 DV Table of Contents Sebago Service Tools .............................................. 3 Direct Vent Gas Heater Specifications ........................................... 4 General Information ............................... 5 Manufactured and Distributed by: Jøtul A.S.A. Safety Information .................................. 6 Fredrikstad, Norway Installation Requirements Jøtul North America Location ................................................. 6 55 Hutcherson Dr. H
ملخص المحتوى في الصفحة رقم 4
GF 400 DV Sebago Specifications Specifications 28 1/2” 724 mm Input Rates Natural Gas 32,000 BTU/hr. maximum input 18,000 BTU/hr. minimum input Propane 26 1/2” 32,000 BTU/hr. maximum input 673 mm 16,000 BTU/hr. minimum input Inlet Pressure: MIN MAX 13” 330 mm Natural Gas: 5.0 WC (1.24 kPa) 7.0 WC (1.74 kPa) Propane: 12.0 WC (2.99 kPa) 14.9 WC (3.71 kPa) Manifold Pressure: MIN MAX Natural Gas: 1.2 WC (.30 kPa) 3.8 WC (.95 kPa) Propane: 2.9 WC (.722 kPa)
ملخص المحتوى في الصفحة رقم 5
General Information THIS HEATER MUST BE INSTALLED AND MAINTAINED Glass Panel BY A QUALIFIED SERVICE AGENCY. Do not operate this appliance with the glass The installation and repair of this appliance must be front removed, cracked, or broken. Replacement done by a qualified service person. Failure to of the glass should be done by a licensed or properly install and maintain this heater could result qualified service person. Only remove glass for in an unsafe or hazardous installation, which
ملخص المحتوى في الصفحة رقم 6
Safety Information Location During normal operation, the GF 400 DV Sebago gas In selecting a location for the stove, consider the stove will reach high surface temperatures. Therefore: following points: 1) Heat distribution 2) Vent termination requirements Due to the high operating temperatures, this appli- 3) Gas supply line routing ance should be located out of traffic areas and away 4) Traffic areas, furniture, draperies, etc. from furniture and draperies. The GF 400 DV Sebago may be lo
ملخص المحتوى في الصفحة رقم 7
Stove and Vent Clearance Requirements Minimum Clearances from the Stove to Combustibles: See figs. 2-4. Rear: 2” (51 mm) 2” (51 mm) Ceiling: 32 1/4” (819 mm) To Rear Wall Corner: 2” (51 mm) Sides: 3” (76 mm) 3” 3” (76 mm) (76 mm) Minimum Clearances from the Vent Pipe to Combustibles: Figure 3. Parallel Installation Clearances. Horizontal Run: Off the top of the pipe 2” (51 mm) Off the sides and bottom 1” (25 mm) Vertical Run: 2” 51 mm All sides 1” (25 mm) ! "
ملخص المحتوى في الصفحة رقم 8
Venting Requirements Vent Restriction The GF 400 DV Sebago is equipped with Restrictor Plates The Jøtul GF 400 DV Sebago gas stove may be installed which enable you to regulate the flow of incoming with a vertical or horizontal termination and must combustion air and exhaust gas. The plates prevent conform to the configuration requirements described overly strong draft that can cause poor combustion and below. weak flame picture. Follow the guidelines below, and on This appliance is appr
ملخص المحتوى في الصفحة رقم 9
FRONT LEG BACK LEG Push the Default '()* Pivot Pin into Factory the slot Setting is “D” '(+ Figure 6. Adjusting the Air Inlet Restrictor plate - View is from the right side of the stove. Vertical Vent Termination The Jøtul GF 400 DV Sebago can be vertically vented through a ceiling or to a roof termination with the following guidelines: The termination should fall within the shaded areas of the grids depicted in the Vent Window diagrams on the pages 10-11. Front
ملخص المحتوى في الصفحة رقم 10
Vent Termination Zones - Natural Gas Vertical Termination for ' COLINEAR VENT $ Horizontal and Vertical Terminations for COAXIAL VENT ' ' $ $ ' , 0 1 2.+3 . 43
5 - ' $ 0.& 6 - ..
5 # ' ' ' $ $ $ ' (!# $)#*+&' ,#./
.& %# $!#)&' ,&2& ,&2& ./
./
' .& .&
ملخص المحتوى في الصفحة رقم 11
Vent Termination Zones - Propane Vertical Termination for ' COLINEAR VENT $ ' Horizontal and Vertical $ Terminations for COAXIAL VENT ' , 0 1 2.+3 . 43
5 - 0.& ' 6 $ - ..
5 # ' $ ' $ ' (!# $)#*+&' %# ,&2& ,&2& $!#)&' ./
./
.& .& %# %# ' $!#)&' $!#)&' 7 8 ,#
ملخص المحتوى في الصفحة رقم 12
High Wind Cap Exhaust Gas Co-linear Vent Installation Max. Co-linear Intake Air Height - 35 ft. The GF 400 DV Sebago may be vented through a ma- (10.66 m) sonry or Class A prefabricated chimney using a Co-linear Min. Co-linear Height - 10 ft. Flexible Vent system approved for use with a solid-fuel (3.05 m) burning fireplace. When installed in the manner de- scribed below, this system can improve the performance of the appliance in cold climate situations, as well as simplify the vent installatio
ملخص المحتوى في الصفحة رقم 13
Vertical Exhaust Masonry or Prefabricated Chimney Termination Gas Cap Conversion Cap Adaptor- included in Intake Air The GF 400 DV Sebago is approved for use with listed #934 Kit chimney conversion kits from any of the manufacturers listed on page 8. These kits are for use in a masonry chimney or a prefabricated solid fuel listed chimney. See 4” Flex Pipe fig. 15. not included in kit These installation requirements must be followed: 1. Use the guidelines for Coaxial Vent Termination appropriate
ملخص المحتوى في الصفحة رقم 14
12 in. (305 mm) Horizontal Termination Any horizontal termination must fall within the shaded portion of the vent window graph illustrated in figs. 9 or 11. For Snorkel Terminations, see below. 24 in. Any horizontal termination except a snorkel termination, Snorkel (305 mm) must include: 14” 355 mm 1) Minimum rise of 2 ft. 57” Max. (1448 mm) 2) Minimum horizontal run of 12 in. when vertical run is less than 8 ft. 2) Maximum rise of 35 ft. 3) Maximum horizontal run of 27 ft. 12” 25 1/2 in.
ملخص المحتوى في الصفحة رقم 15
Horizontal Termination Clearance Figure 19. Vent Terminal Clearances - National Fuel Gas Code. 1 A = Clearance above grade, veranda, porch , deck, or L = Clearance above paved sidewalk or a paved driveway located on public property: 7 feet (2.1 m) min. balcony : 12 inches (30 cm) minimum. M = Clearance under veranda, porch, deck, or balcony: B = Clearance to window or door that may be opened: 2 **Min. 9 inches, U.S. / *12 inches (30 cm) CAN. 12 inches (30 cm) minimum. We recommend 12in. mini
ملخص المحتوى في الصفحة رقم 16
Mobile Home Installation Fuel Conversion The GF 400 DV Sebago can be installed for use in a The GF 400 DV Sebago gas stove is shipped from the mobile home in the U.S. and Canada provided: factory equipped to burn NATURAL GAS only. If PROPANE gas is to be used as fuel, the appliance must first be 1. The stove is secured to the floor of the mobile home. converted for use with propane. Use Propane Conversion Use Jøtul Floor Bracket Kit #154388. Kit 155351, supplied with the appliance. 2. Provisio
ملخص المحتوى في الصفحة رقم 17
Fuel Conversion Procedure Refer to fig. 47, Illustrated Parts Breakdown, to identify Air Shutter part numbers below. + ) Wingnut 1. Turn off gas supply to stove. 2. Remove the stove Top Plate (41). 3. Disengage the two Glass Frame Latches at the top of FRONT the firebox. See illustration on page 5. Carefully lift BACK LEG the glass panel up and out of the stove. LEG 4. If installed, remove the Embers and Log Set using care Figure 21. Locate and remove the Air Shutter wingnut not to damag
ملخص المحتوى في الصفحة رقم 18
NEVER USE AN OPEN FLAME TO CHECK FOR GAS LEAKS. 14. Remove the Regulator Tower, Gasket, white plastic disk, and Spring. Correct gas pressure is essential for efficient and safe operation of this appliance. Correct gas pressure 15. Install the new regulator: Be sure the new gasket is must be established at the time of installation. For properly positioned and tighten screws securely. more details, see the Gas Pressure section of this 16. Install the identification labels to the stove so that t
ملخص المحتوى في الصفحة رقم 19
A T-HANDLE GAS COCK IS REQUIRED IN MASSACHUSETTS TO COMPLY WITH CODE 248CMR. Secure all joints tightly using appropriate tools and sealing compounds. For propane units be sure to use compounds that are propane resistant. Turn on gas supply and test for gas leaks using a soapy water solution. Never use an open flame to check for leaks. E A Figure 28. Pressure test points. Leak test: 1. Mix a 50-50 solution of water and dish soap. 2. Light appliance- see lighting instructions INLET GAS PRESSUR
ملخص المحتوى في الصفحة رقم 20
Flame Appearance / Air Shutter Optional Wall Thermostat or Adjustment Remote Control The GF 400 DV Sebago gas stove is shipped from the Use only a 750 millivolt DC two-wire circuit thermostat factory equipped to burn Natural gas with the air shutter with this appliance. The thermostat should be placed in set at the halfway position. Please be aware, however, the same room as the heater, typically 5 feet off the that this initial setting may not provide the optimal flame floor. Avoid drafty areas