ملخص المحتوى في الصفحة رقم 1
PROPANE
CONSTRUCTION
HEATER
OWNER’S MANUAL
Models: TC275J, RCP2000, and REM2000
IMPORTANT
Read and understand this manual before assembling, starting, or servicing heater.
Improper use of heater can cause serious injury. Keep this manual for future
reference.
GENERAL HAZARD WARNING:
WARNING ICON G 001
FAILURE TO COMPLY WITH THE PRECAUTIONS AND INSTRUCTIONS PRO-
VIDED WITH THIS HEATER, CAN RESULT IN DEATH, SERIOUS BODILY INJURY
AND PROPERTY LOSS OR DAMAGE FROM HAZARDS OF FIRE, EXPLOSION,
BURN, A
ملخص المحتوى في الصفحة رقم 2
SECTION PAGE CONTENTS Safety Information ......................................................................... 2 Product Identification .................................................................... 4 Unpacking...................................................................................... 4 Theory of Operation ...................................................................... 4 Propane Supply .............................................................................. 5 Ve
ملخص المحتوى في الصفحة رقم 3
SAFETY WARNINGS Continued WARNING ICON G 001 INFORMATION Propane Gas: Propane gas is odorless. An odor-making agent is added to propane gas. The odor helps you detect a propane gas leak. However, the odor Continued added to propane gas can fade. Propane gas may be present even though no odor exists. Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this heater. • For indoor use only. Provide adequate ventilation.
ملخص المحتوى في الصفحة رقم 4
PRODUCT Top IDENTIFICATION Note: Debris Shield Not Shown Shell Ignitor Electrode Pilot Base Thermocouple Piezo Ignitor Button Main Burner Valve Handle Main Burner Valve Automatic Inlet Control Valve Connector Button Automatic Hose/Regulator Control Valve Assembly Figure 1 - Product Identification 1. Remove all packing items applied to heater for shipment. Keep plastic cover UNPACKING caps (attached to inlet connector and hose/regulator assembly) for storage. 2. Remove all items from carton. 3. C
ملخص المحتوى في الصفحة رقم 5
You must provide propane gas and propane tank(s). PROPANE Use this heater only with a propane vapor withdrawal supply system. See SUPPLY Chapter 5 of the Standard for Storage and Handling of Liquified Petroleum Gas, ANSI/NFPA 58. Your local library or fire department will have this booklet. The amount of propane gas ready for use from propane tanks varies. Two factors decide this amount. 1. The amount of liquid propane gas in tank(s) 2. The temperature of tank(s) The chart below shows the minimu
ملخص المحتوى في الصفحة رقم 6
INSTALLATION WARNING WARNING ICON G 001 Review and understand the warnings in the Safety Informa- tion Section. They are needed to safely operate this heater. Follow all local codes when using this heater. WARNING WARNING ICON G 001 Test all gas piping and connections for leaks after installation or servicing. Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak. Correct all leaks at once. 1. Provide propane supply sys
ملخص المحتوى في الصفحة رقم 7
5. Check all connections for leaks. Apply mixture of liquid soap and water to gas joints. Bubbles forming show a leak that must be corrected. WARNING WARNING ICON G 001 Never use an open flame to check for a leak. Apply a mixture of liquid soap and water to all joints. Bubbles forming show a leak that must be corrected. Correct all leaks at once. 6. Close propane supply valve. OPERATION WARNING WARNING ICON G 001 Review and understand the warnings in the Safety Informa- tion Section. They are n
ملخص المحتوى في الصفحة رقم 8
5. If pilot light goes out, repeat step 4. 6. When pilot remains lit, fully open main burner valve. Do this by turning main burner valve handle towards the ON position until it stops. Note: Arrows on main burner valve handle show directions for ON and OFF. 7. Adjust main burner valve handle slowly towards the OFF position, for less heat if needed. CAUTION WARNING ICON G 001 Do not operate heater at extremely low BTU (100% yellow flame). This may cause sooting inside heater. To Stop Heater 1. Ti
ملخص المحتوى في الصفحة رقم 9
TROUBLE- WARNING WARNING ICON G 001 SHOOTING Never attempt to service heater while it is connected to propane supply, operating, or hot. Severe burns can occur. You may have further ques- tions about this heater. If so, contact DESA International’s SYMPTOM POSSIBLE CAUSE REMEDY Technical Service Department at 1-800-323-5190. Pilot fails 1. Propane supply valve closed 1. Open propane supply valve to light. on propane tank(s). slowly. 2. Excess-flow check valve 2. Close propane supply valve on cl
ملخص المحتوى في الصفحة رقم 10
Part Number Description ACCESSORIES LPA1020 10' Rubber Hose with Brass Fitting Purchase these accessories U.L. listed. and parts from your local LPA1030 15' Rubber Hose with Brass Fitting dealer or service center. If U.L. listed. your dealer or service center LPA2005 Propane Gas Regulator can not supply an accessory or U.L. listed. part, contact your nearest LPA3005 Hose/Regulator Assembly Parts Central (listed in the U.L. listed. separate Authorized Service LPA4020 Fuel Gas Connector Center boo
ملخص المحتوى في الصفحة رقم 11
This list contains replaceable parts used in your heater. When ordering parts, PARTS LIST follow the instructions listed under Replacement Parts on page 10 of this manual. KEY VMH10TN NO. PART NO. DESCRIPTION QTY. 1 M12461-51 #10-24 x 1/2" Screw 3 8 2 097384-01 Nut, #10-24 3 6 3 097052-01 Standoff Bracket 6 4 M11084-27 Screw, "AB" #10-16 x 1/2" 8 5 098822-01 Half Shell 2 6 097187-01 Pop Rivet, 3/16" 7 7 M50110-01 Pop Rivet (S. S.), 1/8" 10 8 098823-02 Top Deflector 1 9 098827-01 Male Compressio
ملخص المحتوى في الصفحة رقم 12
WARRANTY AND REPAIR SERVICE KEEP THIS WARRANTY LIMITED WARRANTY DESA International warrants this product and any parts thereof, to be free from defects in materials and workmanship for one (1) year from the date of first purchase when operated and maintained in accordance with instructions. This warranty is extended only to the original retail purchaser, when proof of purchase is provided. This warranty covers only the cost of parts and labor required to restore the product to proper operating c