ملخص المحتوى في الصفحة رقم 1
W
A
R
R
DIGITAL
NON-PROGRAMMABLE
9515
® THERMOSTAT
™
INTEGRATED COMFORT SOLUTIONS
G E
GAS ELECTRIC
2 Heat / 2 Cool
User’s Manual
Quick Start
Installation
110-752
IMPORTANT SAFETY INFORMATION
WARNING:
• Always turn off power at the main power source by unscrewing
fuse or switching circuit breaker to the off position before installing,
removing, cleaning or servicing thermostat.
• Read all of the information in this manual before installing or pro-
gramming this thermostat.
• This is a 24V AC
ملخص المحتوى في الصفحة رقم 2
Features • Multi stage heating and cooling control • Zone system compatible as a master thermostat • Auxiliary heat • Fahrenheit/Celsius display option • Adjustable from 45°F (7°C) to 90°F (32°C) • Accuracy within ± 1 degree • Adjustable 1st stage temperature differential: 1°-3°, 2nd stage temperature differential: 2°-6° F • Automatic heating shutdown if temperature exceeds 90°F (32°C) • Battery free memory storage Replacing Existing Thermostat 1. Turn off power to heating and cooling system. 2.
ملخص المحتوى في الصفحة رقم 3
> 4. After labeling wires, remove wires from terminals. 5. Remove existing thermostat base from wall. 6. Refer to the following section for instructions on how to install thermostat. Figure 1 Installing Model 9515 Thermostat NOTE: FOR NEW INSTALLATIONS, MOUNT THERMOSTAT ON INSIDE WALL, 5 FEET ABOVE THE FLOOR. DO NOT INSTALL BEHIND A DOOR, IN A CORNER, NEAR AIR VENTS, IN DIRECT SUNLIGHT, OR NEAR ANY HEAT OR STEAM GENERATING FIXTURES. INSTALLATION AT THESE PLACES WILL AFFECT THERMOSTAT OPERATION.
ملخص المحتوى في الصفحة رقم 4
5. Place thermostat against the wall at desired location. Make sure wires will feed through opening on base of thermostat. 6. Mark placement of mounting holes (Figure 3). Set base aside. Mounting Holes Batteries NOT Required. Figure 3 7. Drill the marked holes using a 3/16" drill bit. NOTE: Enclosed plastic anchors do not require a drilled hole for drywall. 8. Tap plastic anchors into the wall. 9. Align base with plastic anchors and feed wires through opening. 10. Secure base to wall with su
ملخص المحتوى في الصفحة رقم 5
11. Connect wires to terminal strip (refer to wiring diagrams). Make sure wire connections are secure. 12. Set the °F/°C switch to either °F for Fahrenheit display or °C for Celsius display readout (Figure 4). °F/°C Switch Batteries NOT Required. Figure 4 13. Set the GAS/ELEC switch to either GAS for a gas/oil heating system or ELEC for an electric heating system. 14. Replace cover onto thermostat by snapping into place. 15. Turn on power to system. Test thermostat as described in the followi
ملخص المحتوى في الصفحة رقم 6
> > > > > > > > > Operation Setting or Changing the Setpoint Temperature 1. Press either the or button. The display will show the current C temperature setpoint. COOL-OFF-HEAT AUTO - ON AUX 2. Press either the or button to adjust the temperature setting either up or down. The display will return to the room temperature display five seconds after the last input and the new setpoint will be saved. Changing Temperature Differential IMPORTANT: The temperature differential is factory set at 1 (1°
ملخص المحتوى في الصفحة رقم 7
> To Test Thermostat WARNING: DO NOT SHORT (JUMPER) ACROSS TERMINALS OF GAS VALVE OR SYSTEM CONTROL TO TEST OPERATION. THIS WILL DAMAGE THE THERMOSTAT AND VOID YOUR WARRANTY. CAUTION: DO NOT SWITCH SYSTEM TO COOL IF THE TEMPERATURE IS BELOW 50°F (10°C). THIS CAN DAMAGE THE AIR CONDITIONING SYSTEM AND CAUSE PERSONAL INJURY. 1. Place the COOL-OFF-HEAT COOL-OFF-HEAT switch into the COOL position. 2. Press the button until the temperature setting is at least 3 degrees below the room temperatur
ملخص المحتوى في الصفحة رقم 8
Changing Fahrenheit (F) to Celsius (C) The thermostat is preset to display the temperature in degrees Fahrenheit. You may change the display readout to Celsius if desired. 1. Move the manual switch marked F (Fahrenheit) and C (Celsius) locat- ed at the center of the circuit board to the desired setting (page 5). 2. Press RESET button located to the right of the LCD display to register the change. The display will change to show the temperature in your desired temperature scale. To return the
ملخص المحتوى في الصفحة رقم 9
If problems with thermostat cannot be solved, call: Technical Support: (800) 445-8299 Monday-Friday 7:30-5:30 CST For warranty returns, send thermostat, shipping prepaid to: Uni-Line North America Warranty Claims Department 515 S. Promenade Corona, CA 91719 9
ملخص المحتوى في الصفحة رقم 10
Wiring Diagrams The following is just a sample of the most common types of HVAC systems. Refer to your system’s installation manual for wiring information. Robertshaw 9515 Multi-Stage Thermostat C R Y2 Y1 W1 G W2 O B Y/Y1 C R W1 G W2 2 Stage Heat / 1 Stage Cool Robertshaw 9515 Multi-Stage Thermostat C R Y2 Y1 W1 G W2 O B C R Y2 Y1 W1 G W2 2 Stage Heat / 2 Stage Cool 10
ملخص المحتوى في الصفحة رقم 11
Five Year Limited Warranty Maple Chase Company warrants to the original contractor installer, or to the original consumer user, each new Maple Chase thermostat to be free from defects in materials and workmanship under normal use and service for a period of five (5) years from date of purchase. This warranty and our liability does not apply to batteries or merchandise that has been damaged, caused by misuse, neglect, mishandling, alterations, improper installation, or use in a way other than in