ملخص المحتوى في الصفحة رقم 1
Installation
Guide
TH4210D
Programmable Thermostat
ملخص المحتوى في الصفحة رقم 2
Product Application This thermostat provides electronic control of 24 VAC heat pump systems with aux- iliary heat (2 heat/1 cool). Power Type Battery power Common wire Common wire with battery backup System Settings Heat, Off, Cool, Em Heat Fan Settings Auto, On Must be installed by a trained, experienced technician • Read these instructions carefully. Failure to follow these instructions can dam- age the product or cause a hazardous condition. Check the ratings in this booklet to ve
ملخص المحتوى في الصفحة رقم 3
PRO TH4210D Programmable Thermostat Table of contents I In ns st ta alllla at tiio on n A Ap pp pe en nd diic ce es s Pre-installation checklist ................2 Adaptive Intelligent Recovery ........9 Wallplate installation ......................3 Compressor protection ..................9 Wiring..............................................4 Quick reference to controls..........10 Wiring diagrams ..............................5 Quick reference to display............10 In case of difficulty ...
ملخص المحتوى في الصفحة رقم 4
Installation Guide Pre-installation checklist Package contents Check to make sure your package includes the following items: PRO TH4210D digital thermostat (wallplate attached to back) Operating manual Wall anchors and mounting screws (2 each) AA alkaline batteries (2) Quick reference card Required tools & supplies No. 2 Phillips screwdriver Small pocket screwdriver Drill Drill bit (3/16” for drywall, 7/32” for plaster) Hammer Pencil Electrical tape Level (optional) 2
ملخص المحتوى في الصفحة رقم 5
PRO TH4210D Programmable Thermostat Wallplate installation Grasp top and bottom of wallplate Remove the wallplate from the ther- and pull to remove from thermostat. mostat as shown at left, then follow directions below for mounting. 1 Pull wires through wire hole. 2 Position wallplate on wall, level and mark hole positions with pencil. 3 Drill holes at marked positions as shown below, then tap in supplied wall anchors. 4 Place wallplate over anchors, insert and tighten mounting screws. 5 Insert
ملخص المحتوى في الصفحة رقم 6
Installation Guide Wiring CAUTION: ELECTRICAL HAZARD. Can cause electrical shock or equipment damage. Disconnect power before wiring. Wiring Keep wires in this shaded area 1 Loosen screw terminals, insert wires into terminal block, then re- tighten screws. 2 Push excess wire back into the wall opening. Keep wires in shaded area as shown at left. 3 Plug the wall opening with non- flammable insulation to prevent drafts from affecting thermostat operation. Terminal Terminal Designations block E E E
ملخص المحتوى في الصفحة رقم 7
PRO TH4210D Programmable Thermostat Wiring diagram 1 Power supply. Provide disconnect means and overload protection as required. 2 Optional 24 VAC common connection. 3 Use either O or B terminals for changeover valve. 4 L terminal is powered continuously when thermostat is set to Em Heat. 5 Install field jumper between E and Aux if there is no emergency heat relay. 5
ملخص المحتوى في الصفحة رقم 8
Installation Guide Power options & mounting AC Power The thermostat can be powered by 24 VAC power, or by batteries. To wire the thermostat for AC power, connect the common side of the Connect common transformer to the “C” terminal as side of transformer shown at left. to “C” terminal Battery Power The thermostat can be powered by batteries alone or, if used with AC power, can provide backup power. During power interruptions the batteries will save time/day settings and power the display. Inst
ملخص المحتوى في الصفحة رقم 9
PRO TH4210D Programmable Thermostat Installer setup Follow the procedure below to configure the thermostat to match the installed heating/cooling system, and customize feature operation as desired. Press and hold both buttons Function Setting number Setup 5 6 To begin, press and holdthe and Press to change settings buttons until the display changes Press to advance to next function Press and hold to exit and save settings Setup Function Settings & Options 6 Auxiliary heat 5 For gas or oil furnac
ملخص المحتوى في الصفحة رقم 10
Installation Guide Installer system test Follow the procedure below to test the heating and cooling system. System test System status number 0 10 Test System switch 1 Set S SY YS STTEEM M switch to Heat. 2 Press to turn on and check systems (see table, below). 3 Press until systems turn off. 4 Set S SY YS STTEEM M switch to Em Heat and repeat steps 2-3 above. 5 Set S SY YS STTEEM M switch to Cool and repeat steps 2-3 above. 5Press and hold to terminate test at any time. System Test System Status
ملخص المحتوى في الصفحة رقم 11
PRO TH4210D Programmable Thermostat ™ Adaptive Intelligent Recovery (Setup Function 13) Adaptive Intelligent Recovery eliminates guesswork when setting your schedule. It allows the thermostat to “learn”how long your furnace and air conditioner take to reach the temperature you want. Just set your program schedule to the time you want the house to reach your desired temperature.The thermostat then turns on the heating or cooling at just the right time to reach your scheduled temperature at your s
ملخص المحتوى في الصفحة رقم 12
Installation Guide Quick reference to controls Temperature adjustment Set: Press to set time/day/ schedule Hold: Press to override programmed temperature control. Run: Press to resume program schedule System switch Cool: Thermostat controls only the cooling system. Heat: Thermostat controls only the heating system. Fan switch Off: Heating and cooling On: Fan runs continuously. systems are off. Auto: Fan runs only when heating Em Heat: Thermostat controls or cooling system is on.
ملخص المحتوى في الصفحة رقم 13
PRO TH4210D Programmable Thermostat In case of difficulty If you have difficulty with your thermostat, please try the suggestions below. Most problems can be corrected quickly and easily. Display is blank Check circuit breaker and reset if necessary. Make sure heating & cooling power switches are on. Make sure equipment door is securely closed. If battery powered, make sure fresh AA alkaline batteries are installed. Temperature Make sure heating and cooling temperatures are set to accept
ملخص المحتوى في الصفحة رقم 14
Installation Guide Accessories Please contact your distributor to order accessories. Cover plate assembly ............................................Part Number 50002883-001 (Used to cover marks left by old thermostats.) Specifications Temperature Ranges Electrical Ratings Heat: 40° to 90°F (4.5° to 32°C) Cool: 50° to 99°F (10° to 37°C) System Voltage (50/60Hz) Running Current st Heat (1 stage) 20-30 Vac 0.02-1.0 A Operating Ambient Temperature 32° to 120°F (0° to 48.9°C) Emergency heat 2
ملخص المحتوى في الصفحة رقم 15
ملخص المحتوى في الصفحة رقم 16
Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 55422 Scarborough, Ontario M1V 4Z9 http://yourhome.honeywell.com Printed in U.S.A. on recycled paper containing at least 10% post-consumer paper fibers. ® U.S. Registered Trademark. © 2005 Honeywell International Inc. Patents pending. All rights reserved. 69-1763 06-2005