CONTENTS Welcome Introduction........................................................................................................................................2 SAFETY PRECAUTIONS Safety rules .......................................................................................................................................3 Operating condition ...........................................................................................................................3 Electrical informat
ملخص المحتوى في الصفحة رقم 3
INTRODUCTION When using this air conditioner, please keep the following information in mind: DISPOSAL: Do not dispose of this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. It is prohibited to dispose of this appliance in domestic household waste. For disposal, the following options may be available: A) The municipality has established collection systems, where electronic waste can be bedisposed of free of charge to the user.
ملخص المحتوى في الصفحة رقم 4
SAFETY PRECAUTIONS Safety rules To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. Always Do This: Never Do This: ! Do not operate your air conditioner in a wet room such as a bathroom or laundry room. Your air conditioner should be used in such a way Do not touch the unit with wet or damp hands or that it is protected from moisture. e.g.
ملخص المحتوى في الصفحة رقم 5
SET TEMPERATURE( C) AUTO FAN COOL HIGH DRY MED HEAT LOW TEMP MODE ON/OFF FAN SPEED SWING ECONOMY TIMER ON ION RESET LOCK TIMER OFF FOLLOW LED ME DISPLAY TURBO IDENTIFICATION OF PARTS WARNING For your safety Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. Avoid fire hazard or electric shock. Do not use an extension cord or an adaptor plug. Do not remove any prong from the power cord. WARNING Ele
ملخص المحتوى في الصفحة رقم 6
IDENTIFICATION OF PARTS NAMES OF PARTS 1 Front 2 Operation Panel 1 4 2 Horizontal Louver Blade (Swing automatically) 3 Caster 4 Carrying Handle (Both sides) 3 Fig.1 Model A 2 1 Operation Panel 3 1 5 2 Horizontal Louver Blade (Manual) 3 Remote signal receptor 4 Caster 5 Carrying Handle 4 (Both) Model B Fig.2 Rear 6 Upper Air Filter 6 (Behind the grille) 9 Air Outlet 7 Power Cord Outlet 8 10 7 Air Intake 9 Drain Outlet 10 11 11 Air intake 8 12 Lower Air Filter 12 (Behind the grille) 13 Bott
ملخص المحتوى في الصفحة رقم 7
AIR CONDITIONER FEATURES ELECTRONIC CONTROL OPERATING INSTRUCTIONS Before you begin, thoroughly familiarize yourself with the control panel and remote controller and all its functions, then follow the symbol for the functions you desire. The unit can be controlled by the unit control panel alone or with the remote controller . NOTE: This manual does not include remote control operation instructions.Please see the Remote Control Operation Instructions packed with the unit for details. OPERA
ملخص المحتوى في الصفحة رقم 8
OPERATING INSTRUCTIONS SWING button FAN operation 8 (Applicable to the models with auto swing feature only) - Press the "MODE" button until the When power is ON, press the SWING "FAN" indicator light comes on. button to stop the louver at the desired - Press the "FAN SPEED" button to angle. The angle of the louver increases choose the fan speed. The temperature 6° for each press. Hold the button down cannot be adjusted. for 2 seconds or longer to initiate the -
ملخص المحتوى في الصفحة رقم 9
OPERATING INSTRUCTIONS Other features Power Outage In case of a power outage or interruption, the unit will automatically re-start, in the settings last used, after the power is restored. Wait 3 minutes before resuming operation After the unit has stopped, operation cannot Adjust manually be restarted for the first 3 minutes after power has been restored. This is to protectthe unit. Operation will automatically start after 3 minutes. Air flow direction adjustment The louver can be adjuste
ملخص المحتوى في الصفحة رقم 10
B B INSTALLATION INSTRUCTIONS (optional) INSTALLATION INSTRUCTIONS Location The air conditioner should be placed on a firm foundation to minimize noise and vibration. For or safe and secure positioning, place the unit on a smooth, level floor strong enough to support the unit. The unit has casters to aid placement, but it should only be rolled on smooth, flat surfaces. Use caution Fig.7 A:30cm-100cm B:30cm when rolling on carpet surfaces. Do not attempt to roll the unit over objects. The
ملخص المحتوى في الصفحة رقم 11
INSTALLATION INSTRUCTIONS (optional) Installation in a double-hung sash Foam seal A (adhesive type) window 1. Cut the foam seal (adhesive type) to the proper length and attach it to the window stool. Fig.10 Fig.10 2. Attach the window slider kit to the window stool. Adjust the length of the window slider kit according Window kit to the width of window; shorten the adjustable window kit if the width of window is less than 22.1 inches. Open the window sash and place the windo
ملخص المحتوى في الصفحة رقم 12
INSTALLATION INSTRUCTIONS (optional) Installation in a sliding sash Foam seal A window (adhesive type) 1. Cut the foam seal (adhesive type) to the proper length and attach it to the window frame,Fig.14. Fig.14 2. Attach the window slider kit to the window stool. Adjust the length of the window slider kit according Window to the width of window; shorten the adjustable window panel kit if the width of window is less than 22.1 inches. Open the window sash and place the window
ملخص المحتوى في الصفحة رقم 13
INSTALLATION INSTRUCTIONS (optional) Exhaust hose installation: The exhaust hose and adaptor must be installed or removed in accordance with the usage mode. Fig.18a Fig.18b COOL,HEAT(heat pump type) or AUTO Install mode FAN,DEHUMIDIIFY or HEAT(electrical heat type) Remove mode 1. Install the window exhaust adaptor B onto the exhaust hose as shown in Fig.18a. or Fig.18b. Refer to the previous page
ملخص المحتوى في الصفحة رقم 14
INSTALLATION INSTRUCTIONS Water drainage: - During dehumidifying modes, remove the drain Remove the plug from the back of the unit; install the drain drain plug connector (5/8 universal female mender) with 3 4 hose (not included). For the models without drain connector, just attach the drain hose to the hole. Place the open end of the hose directly over the drain area in your basement floor. Please refer to Fig. 23 & 24. Fig.23 - When the water l
ملخص المحتوى في الصفحة رقم 15
CARE AND MAINTENANCE CARE AND MAINTENANCE Air filter (slide out) IMPORTANT: 1) Be sure to unplug the unit before cleaning or servicing. 2) Do not use gasoline, thinner or other chemicals to clean the unit. 3) Do not wash the unit directly under a tap or using a hose. It may cause electrical danger. 4) If the power cord is damaged, it should be repaired by Fig.26 manufacturer or its agency. 1. Air filter - Clean the air filter at lea
ملخص المحتوى في الصفحة رقم 16
TROUBLESHOOTING TIPS TROUBLE SHOOTING TROUBLES POSSIBLE CAUSES SUGGEST REMEDIES 1. Unit does not - P1 appears in the display window Drain the water in the bottom tray. start when pressing on/off - Room temperature is lower than Reset the temperature. button the set temperature.(Cooling mode) - The windows or doors in the room Make sure all the windows and are not closed. doors are closed. - There are heat sources inside the Remove the heat sources if possible. 2. No
ملخص المحتوى في الصفحة رقم 17
LIMITED MANUFACTURER’S WARRANTY This appliance is covered by a limited manufacturer’s warranty. For one year from the original date of purchase, the manufacturer will repair or replace any parts of this appliance that prove to be defective in materials and workmanship, provided the appliance has been used under normal operating conditions as intended by the manufacturer. Warranty Terms: During the first year, any components of this appliance found to be defective due to materials