ملخص المحتوى في الصفحة رقم 1
TEC Electronic Computing Scale
SL-9000-ESB SERIES
Owner’s Manual
ملخص المحتوى في الصفحة رقم 2
ملخص المحتوى في الصفحة رقم 3
Safety Summary Safety Summary Personal safety in handling or maintaining the equipment is extremely important. Warnings and Cautions necessary for safe handling are included in this manual. All warnings and cautions contained in this manual should be read and understood before handling or maintaining the equipment. Do not attempt to effect repairs or modifications to this equipment. If a fault occurs that cannot be rectified using the procedures described in this manual, turn off the power, u
ملخص المحتوى في الصفحة رقم 4
Safety Summary Disconnect Disconnect If foreign objects (metal fragments, When unplugging the power cords, the plug. the plug. water, liquids) enter the machines, be sure to hold and pull on the plug first turn off the power switches and portion. Pulling on the cord portion disconnect the power cord plugs from may cut or expose the internal wires the outlet, and then contact your and cause fire or electric shock. authorized TOSHIBA TEC repre- sentative for assistance. Continued use of the
ملخص المحتوى في الصفحة رقم 5
ملخص المحتوى في الصفحة رقم 6
ملخص المحتوى في الصفحة رقم 7
TABLE OF CONTENTS Page 1.INTRODUCTION ............................................................................................. 1-1 1.1 APPLICABLE MODEL ........................................................................... 1-2 1.2 ACCESSORIES .................................................................................... 1-2 2.SPECIFICATION ............................................................................................. 2-1 2.1 SCALE...............................
ملخص المحتوى في الصفحة رقم 8
Page 12.PROGRAMMED DATA VERIFICATION REPORTS ....................................... 12-1 13.PASSWORD SECURITY ................................................................................. 13-1 13.1 SETTING PASSWORD AND PROTECT MENU................................... 13-1 13.2 CALLING MENU BY ENTERING PASSWORD .................................... 13-3 14.OPERATING PROCEDURES ......................................................................... 14-1 14.1 WEIGHING OPERATION ...............
ملخص المحتوى في الصفحة رقم 9
1. INTRODUCTION 1. INTRODUCTION 1. INTRODUCTION Thank you for purchasing the TEC SL-9000-ESB Series electronic computing scale. As you will discover, the TEC SL-9000-ESB series has many features and functions designed for user friendliness as well as complete customer satisfaction. The 7-segment fluorescent display which indicates transaction information such as weights, unit prices, total prices, etc. and the liquid crystal display used to display commodity names and programming messages are p
ملخص المحتوى في الصفحة رقم 10
1. INTRODUCTION 1.1 APPLICABLE MODEL 1. INTRODUCTION 1.1 APPLICABLE MODEL • SL-9000-30M-ESB-US • SL-9000-15M-ESB-CA • SL-9000-15M-ESB-QR The description of the model number is as follows. S L - 9 0 0 0 - 3 0 M - E S B - U S Destination Code Max. Capacity ex.) US, CA, QR etc. 30M: 30 lbs (decimal Keyboard Type pound/multi-interval) B: Built-in keyboard 15M: 15 Kg (multi-interval) Display Type/Other Spec. Display: Liquid Crystal Display and 7 Segment Dsiplay Spec.: Standalone 1.2 ACCESSORIES Owner
ملخص المحتوى في الصفحة رقم 11
2. SPECIFICATION 2.1 SCALE 2. SPECIFICATION 2.1 SCALE Item US CA QR Maximum Capacity 30 lb 15 Kg (30 lb) 15 Kg Minimum Scale Division 0.005 lb (0~15 lb) 0.002 Kg (0 ~ 6 Kg) 0.002 Kg (0~6 Kg) 0.005 Kg (6 ~ 15 Kg) 0.005 Kg (6~15 kg) 0.01 lb (15~30 lb) 0.005 lb (0 ~ 15 lb) 0.01 lb (15 ~ 30 lb) Maximum Tare 2.000 lb 1.000 Kg (2.205 lb) 1.000 Kg Display Range 0 ~ 30.05 lb 0 ~ 15.025 Kg 0~15.000 Kg (0 ~ 30.05 lb) Unit Price Presettable $0.01 ~ 99.99 $0.01 ~ 99.99 0~99999 Minimum Price Display $0.01 $0
ملخص المحتوى في الصفحة رقم 12
3. APPEARANCE 3. APPEARANCE 3. APPEARANCE Main Power Switch Drawer I/F Remote Display CMT/PL-3 I/F Meat Platter Power Cord Right Cover Adjustable Legs Speed Keyboard and Programming Keyboard Operation Keyboard Print Head Level Gauge Liquid Crystal Display 3-1
ملخص المحتوى في الصفحة رقم 13
4. DISPLAY 4.1 US TYPE 4. DISPLAY 4.1 US TYPE • US (UNITED STATES) WEIGHT e=d CAPACITY SL-9000 0 ~ 15 lb 0.005 lb 15 ~ 30 lb 0.01 lb WEIGHT lb PRICE/lb $ TOTAL PRICE $ %/T NET REG. M/D R/W PREPACK X Z ERROR 4.2 CA TYPE Since the following two remote display sheets are enclosed with the CA machine, select one and affix it to the remote display. (Refer to Section 7 How to affix the remote display sheet.) • CA (CANADA) WEIGHT e=d WEIGHT e=d CAPACITY SL-9000 0 ~ 6 Kg 0.002 Kg 0 ~ 15 lbs 0
ملخص المحتوى في الصفحة رقم 14
4. DISPLAY 4.3 QR TYPE 4.3 QR TYPE WEIGHT e=d TARE Max. 15 Kg SL-9000 0 ~ 6 Kg 0.002 Kg T=-1 Kg Min 0.04 Kg 6 ~ 15 Kg 0.005 Kg A B For the QR machine, the following multi-linqual display stickers are provided to adapt machines to use in various countries. Select one of them and affix it to positions A and B on the remote dis- play. (Refer to Section 7 How to affix the remote display sheet.) • AG/CL (ARGENTINA/CHILE) PESO kg PRECIO UNITARIO $/kg PRECIO TOTAL $ Affix to position A CERO NE
ملخص المحتوى في الصفحة رقم 15
5. KEY LAYOUT 5.1 PROGRAMMING KEYBOARD 5. KEY LAYOUT 5.1 PROGRAMMING KEYBOARD SET NEXT AUTO CLEAR SHIFT NEXT PLU CODE CHANGE DELETE RETURN SEND RECEIVE › fl PLU PLU 1/4 DELETE INSERT DELETE PROG. ENTER - TEST ‹ fi (A) 1 (B) 1/2 ! " # $ % & ´ ` ? @ 1 2 3 4 5 6 7 8 9 0 * + ( ) / : ; < = > Q W E R T Y U | O P [ \ ] ˆ - { } ~ A S D F G H J K L - È É Â Ê fi ‹ fl › . Z X C V B N M SPACE , ZERO FEED NOTE: Blank keys have no function. Programming Keyboard Function Function Name of Key 1. Clears preceding n
ملخص المحتوى في الصفحة رقم 16
5. KEY LAYOUT 5.1 PROGRAMMING KEYBOARD Name of Key Function 1. Displays the preceding PLU data. 2. Used to set an auto code. _ 3. Calls the preceding label format # when setting the print position. 4. Selects a prgramming item. Moves the cursor to the left. ‹ Moves the cursor to the right. fi 1. Deletes a selected character. DELETE 2. Sets a unit price per 1/2 lb. (A) 1/2 1. Inserts a space when entering characters. INSERT 2. Toggles between 100 g and Kg, or used to select Lb when setting unit pr
ملخص المحتوى في الصفحة رقم 17
5. KEY LAYOUT 5.2 OPERATION KEYBOARD AND SPEED KEYBOARD 5.2 OPERATION KEYBOARD AND SPEED KEY BOARD 1 Primary function US type CA/QR type 2 Secondary function 1 1/2 100 g 2 1/4 LB/kg 1 2 3 4 5 6 7 8 9 1 ESC. PROG. POWER 10 11 12 13 14 15 16 17 18 NEXT VOID 2 PLU 19 20 21 22 23 24 25 26 27 PRESET SAVE FOR DT/TM COUNT 28 29 30 32 32 33 34 35 36 GRADE 78 9 LINE 37 38 39 40 41 42 43 44 45 LOGO 45 6 46 47 48 49 50 51 52 53 54 GROUP# 12 3 55 56 57 58 59 60 61 62 63 ST 0 TC 64 65 66 67 68 69 70 PLU PRT/
ملخص المحتوى في الصفحة رقم 18
5. KEY LAYOUT 5.2 OPERATION KEYBOARD AND SPEED KEYBOARD Name of Key Function Prints the customer label. PRT/* Saves tare and unit price after taking off the commodity from a platter. SAVE Sets the quantity of commodity in "BY COUNT" mode. FOR Displays the date. DT/TM 1. Selects the item for change Print/OFF. NEXT 2. Selects a programming item and a main menu. PLU 1. Cancels preceding data. VOID 2. Selects a programming item and a main menu. 1. Enables calling the other 70 speed keys. 2. Selects
ملخص المحتوى في الصفحة رقم 19
5. KEY LAYOUT 5.2 OPERATION KEYBOARD AND SPEED KEYBOARD Name of Key Function Displays a total amount. ST This key is used for item or subtotal discount by entering a percentage. % (Optional key by initial setting) Feeds the label. FEED Issues a test label. TEST Adjusts the zero point. ZERO Changes the label issue mode between Automatic issue and manual AUTO/ issue. (Optional key by initial setting) MANUAL 1 70 Calls the PLU frequently used. to NOTE: In ESB limited specification mode Speed key (
ملخص المحتوى في الصفحة رقم 20
6. PROCEDURE BEFORE OPERATION 6. PROCEDURE BEFORE OPERATION 6. PROCEDURE BEFORE OPERATION 1. Unpack the accessories and scale from the carton. 2. Install the remote display on the scale. (See Page 7-1.) 3. Refer to safety Precautions in this manual and set up the scale in a proper location. 4. Load the label or receipt. (See Page 9-1.) 5. Be sure to insert the power cord plug into an AC outlet. 6. Adjust the level gauge. (See page 8-1.) 7. Turn the power on and then press the power key. (See