ملخص المحتوى في الصفحة رقم 1
Owners Manual -
TEC LOAD CELL SCALE
(WITH LABEL PRINTER)
MODEL SL59 SERIES
(US-l. Version)
r&c TOKYO ELECTRIC CO.,LTb.
ملخص المحتوى في الصفحة رقم 2
El.04189 TABLE OF CONTENTS Page INTRODUCTION, PRECAUTIONS ....................................................................................... 2 3 ....................................................................................... 1. SPECIFICATIONS, DIMENSIONS 4 2.3. OUT OF VIEW, REMOTE DISPLAY ................................................................................. 4. KEY ARRANGEMENT .......................................................................................
ملخص المحتوى في الصفحة رقم 3
El-04189 INTRODUCTION We thank you very much for purchasing our TEC Electronic SL59 Series Scale. This series has been desingned with TEC reliability and offer a cost efficient system for a modest invest- ment. And the SL59 (with thermal printer) takes advantage of the latest technology in microprocessors. Because of this, the decreased cabinet size permits the system to be placed virtually anywhere in your store. Your deli, and specialty departments can enjoy these high quality reliable
ملخص المحتوى في الصفحة رقم 4
El-04189 1. SPECIFICATION SL59-15L-us-1 SL59-3OL-us-1 ‘ Items 15lbs 30lbs Max. Capacity 0.01 lb Minmum Scale Division 0.005lb Display Range 0 - 15.025lb 0 - 30.05lb Unit Price Presettable $0.01 - 99.99 Same as SL59-15L 0.005lb - 9.995lb 0.01 lb - 30.00lb Tare Remote Display: Weight 5 digits 4 digits Unit Price 4 digits 4 digits Total Price 5 digits 5 digits 102 Capacity of PLU memory - 290 PLUS (Standard type) (It depends on each PLU capacity.) Same as SL59-15L Display Designa
ملخص المحتوى في الصفحة رقم 5
El-04189 2. OVERVIEW Remote Display Unit Price Display Total Price Display RK-3 Alpha Keyboard (Option) ---Printer Cover “Auto” or “Manual” Switch ” “Fix price” or “By count”Switch “Weight , 3. REMOTE DISPLAY r 1 -4-
ملخص المحتوى في الصفحة رقم 6
El-04189 4. KEY ARRANGEMENT 5. KEY AND LAMP FUNCTIONS Functions Name of Key & Lamp Label issue Mode Switch (1) “AUTO” position: This position is used to issue regular scale labels. AUTO When the weight becomes stable, the label will automatically be issued. , 7 “MANUAL” position: MANUAL I!! When the weight becomes stable, the label will be issued by depressing y Key. LJ Label Issue Mode Switch (2) “WEIGH” position: This position is used in weighing function of SL59. -WEIGH “
ملخص المحتوى في الصفحة رقم 7
El-04189 Functions Name of Key & Lamp This key is used to subtract tare weight. TARE Key ~~ 1. This key is used to save tare and unit price after taking off the com- SAVE Key modity from a platter. 2. This key is used for CMT operation. 3. This key is used for adjustment of label spacing. _--~ -__~- 1. This key is used to indicate the time and date on remote display. 2. This key is used to change the date. . For issuing “By count” label with split price 2. In “X”, “Z” control lock
ملخص المحتوى في الصفحة رقم 8
El-04189 6. MAIN CONTROL LOCK The control lock has eight marked positions. There are four control keys which will operate these locks, these are: This key (OP) will access the REG and OFF positions. This key (MAl) will access the PR2, PRl , REG, OFF and X po- sitions. This key (MA2) will access the PR2, PRl, REG. OFF, X and Z positions. J Control lock This key (SE) will access all eight positions. (SE key may be kept with your TEC representative for servic- ing.) PR2 - Date, t
ملخص المحتوى في الصفحة رقم 9
El-04189 7. ALPHA KEYBOARD (OPTION) (Option) ALPHA KEYBOARD The SL59 system has the capability to be interfaced with a separate alpha key- board. This typewriter format keyboard greatly enhances the system by allowing (RK-3-1) the programming of alpha descriptors for PLU’s or Commodities. All price pro- gramming can be done through the 57 keys alpha keyboard including pricing by 1/2poundand1/4pound. ALPHA KEYBOARD The alpha keyboard is used with the MA1 or MA2 key at the control lock P
ملخص المحتوى في الصفحة رقم 10
El-04189 RETURN KEY The programming of a two line descriptor can be performed by depressing the -1 key which returns the carriage. f RETURN 1 When a PLU is no longer to be maintained in the PLU file the [ DELETE 1 key is DELETE KEY used to remove the PLU. GRADE KEY The [GRADE] key is not used in the SL59 system. 1 GRADE ] ENTER KEY During programming, data is input to the SL59 system by using the -1 key. 1 ENTER 1 CLEAR KEY The function of the I] key on the alpha keyboard is identica
ملخص المحتوى في الصفحة رقم 11
El-04189 8. CASSETTE MAGNETIC TAPE OPERATIONS The SL59 is designed to interface with a cassette magnetic tape. This tape unit allows the transfer of the entire PLU file from the SL59 to the tape. This can be accomplished using a number of operation steps. In turn, information from the tape can also be transferred to other SL59. 1) SAVE (SL59 + CMT) Control lock: PRl position Start the tape to be recorded after entire rewinding. I Index 111 Confirm the magnetic painted part of tape runn
ملخص المحتوى في الصفحة رقم 12
9. LEVEL ADJLUSTMENT Level Gauge Set the scale on a stable and level surface. Level the scale by turing the adjustable legs so that the air bubble is inside the center circle. Correct Incorrect When the air bubble moves toward rear, When the air bubble moves toward the left side, turn the front adjustable legs clockwise. turn the right adjustable legs clockwise. lo-NOTES BEFORE STARTING .OPERATION (1) Be sure to insert the power plug into AC outlet. (2) When the power plug is connect
ملخص المحتوى في الصفحة رقم 13
E1-041Ll9 11. OPERATING SECTION . - 13 -
ملخص المحتوى في الصفحة رقم 14
El-04189 11-l NORMAL OPERATION A. Weighed Article Registration Control lock: Label issue mode SW.: -WEIGH REG - FIX PRICE - BY COUNT @ Example: In case of a commodity of In case of a commodity with a In case of a commodity of which PLU # 1501 and a unit which unit price of $25.00/ib unit price of $25.00/lb. is programmed for PLU # (Random Items PLU) price of $25.00/lb are pro- grammed in direct key q 1501. (Optional function by Dip switch) 1 PLU 0 (Direct key) Q ~~51jo1[01
ملخص المحتوى في الصفحة رقم 15
El-04189 B. Non Weighed Article Registration REG -WEIGH Label issue mode SW: Control lock: - FIX PRICE -BY COUNT 1) BY COUNT(l) j--x-r/ WEIGHT display: Example: in the event of a unit price of In the event that PLU # 1503 In the event that a unit price of $4.70. $4.70/lb is programmed for and a unit price of $4.70/lb are PLU # 1503. (Random Items PLU) programmed in Direct key II_] . (Optional function by Dip switch) 1 Cl PLU PRICE/Ib PRICE/lb tl pGq pi-j 7 T. PRICE (
ملخص المحتوى في الصفحة رقم 16
El-04189 2) BY COUNT (2): Split price procedures-l Example: In case of purchasing 17 PCS. of article for $4.70 of unit price for 8 PCS. 1 (Direct key) cl I PRICE/lb PRICE/lb pq PLU 1 h PRICE/lb T. PRICE p7-J ( Quantity of purchase. (Can be ommitted.) Max. 2 digits. p7-j -4.70 Quantity for that unit price. (Can be omitted.) Max. 2 digits. l-6-l 14.70 AUTO AUTO , w MANUAL MANUAL The label is issued in succession Single label is issued. after peeling it. ORANGE I 192
ملخص المحتوى في الصفحة رقم 17
El-04189 3) BY COUNT (3): Split price procedures-2 For Open unit price and Random Items PLU. (Direct key) PRICE/lb PRICE/lb 11 piiiq (Optional func- (Open Unit Price) tion by Dip f r\rritrh\ .z..l,“,,, PRICE/lb T. PRICE Quantity of purchase. (Max. 2 digits.) 1 PI7 1 1 0.001 Quantity for that unit price. (Max. 2 digits.) PRICE/lb T. PRICE Unit price for 8 PCS. p5-l rxq ($4.70) AUTO ;TO MAN; : 1 zAL 1 MANUAL The label is issued in succession Single label is issued.
ملخص المحتوى في الصفحة رقم 18
El-04189 C. Fix Price Registration REG Label issue mode SW.: -WEIGH Control lock: - FIX PRICE 63 -BY COUNT Example: In the event that PLU # 1503 In the event that a unit price of $9.40/lb is programmed for and a unit price of $9.40/lb are programmed in Direct key I’.I PLU # 1503 T. PRICE T. PRICE pq pzq TOTAL WEIGHT PRICE/lb PRICE Place the Tare on. 1 0.15 1 [ . 1 1 9.40 1 (0.15lb) NET PREPACK Depress: I ?i- \‘I -7y NET WEIGHT PRICE/lb T. PRICE (T. PRICE is fixed.) p
ملخص المحتوى في الصفحة رقم 19
El-04189 D. Tare function procedure There are two kinds of tare subtraction procedures, one is “Direct tare”, another is “Preset tare”. 1) Direct tare subtaction (A) WEIGHT PRICE/lb TOTAL PRICE Fo.00 IpI pEiq Initial mode: Tare 1 .OOlb / Put on Tare. 6% I NET I P I l-6E-l 1 0.00 1 Depress: NET I 0000 I f-7x-l Take off tare. zz 2) Direct tare subtraction (B) Ip1 I 0000 I PLU NO. I 0100 I Ex.) 1;1F]F] l-KG--l I 0.00 I Depress: PLU r Tare 0.15lb Unit Price stored in PLU
ملخص المحتوى في الصفحة رقم 20
El.04189 4) Preset tare subtraction (A) PRICE/lb TOTAL PRICE . WEIGHT pq Initial mode: Ip1 Ex.) 1.50 Tare weight I NET 1 0000 1 T Depress: cl 5) Preset tare subtraction (B) : Random Items PLU TOTAL PRICE WEIGHT PRICE/lb 1 0.00 ] l-F---l ptiq Initial mode: [ 0.00 ] I l---Gil Ex.) Tare weight 1.501 lb Index: mmm NET I I 0.00 I I -1.50 1 Depress: * As for 15lb capacity scale, entry weight for preset tare must be integer times of 5. Ex.) 1.05,0.05,0.10, 1.15lb The above